文献速递腹部技术与安全CT

双能动态肝脏CT三期图像中真实平扫与虚拟平扫对肌肉和脂肪测量的比较

Comparison of Muscle and Fat Measurements Between True Noncontrast and Virtual Noncontrast Images From Three Phases of Dual-Energy Dynamic Liver CT.
PubMed 文献 · Acad Radiol · 2025-05-19

回顾性分析476例动态肝脏双能CT检查,比较真实平扫与动脉期、门静脉期及延迟期虚拟平扫对肌肉和脂肪的自动分割测量差异。TNC与各VNC图像间肌肉密度、肌肉面积及脂肪衰减存在显著差异,但门静脉期和延迟期VNC的肌肉减少症患病率与TNC无显著差异。作者认为VNCp和VNCd可能可接受用于测量肌肉和脂肪面积,但TNC与VNC图像不应互换用于评估组织衰减或特定肌肉成分。

要点

  • TNC图像肌肉密度高于所有VNC图像,骨骼肌面积小于所有VNC图像(P<0.001)。
  • TNC图像内脏脂肪和皮下脂肪衰减均显著低于所有VNC图像(P<0.001)。
  • TNC与VNCp或VNCd的肌肉减少症患病率无显著差异(无论使用哪种肌肉指数)。

核心结论

  • 尽管TNC与VNC图像在肌肉和脂肪衰减上存在显著差异,VNCp和VNCd可能可接受作为测量肌肉和脂肪面积的替代方法,但TNC与VNC图像不应互换用于评估组织衰减或特定肌肉成分如LAMA或NAMA。

研究设计与样本

  • 回顾性分析2019年4月至2020年12月间476例动态肝脏双能CT检查(男307例,平均年龄58.4±12.5岁),由动脉期、门静脉期和延迟期生成VNCa、VNCp和VNCd图像,用自动分割软件测量肌肉、内脏脂肪和皮下脂肪面积,肌肉减少症用肌肉相关指数定义,采用配对t检验和McNemar检验比较。

关键影像表现/征象

  • TNC图像的平均肌肉密度高于所有VNC图像,且骨骼肌面积小于所有VNC图像(P<0.001)。
  • TNC图像的内脏脂肪和皮下脂肪衰减均显著低于所有VNC图像(P<0.001)。

诊断标准与关键数值

  • 肌肉减少症依据肌肉相关指数定义,TNC与VNCp或VNCd的患病率无显著差异(无论使用哪种肌肉指数)。
  • TNC与VNC图像间肌肉密度、肌肉面积、内脏脂肪衰减和皮下脂肪衰减差异均有统计学意义(P<0.001)。

临床应用与阅片要点

  • VNCp和VNCd可能可接受用于自动分割软件测量肌肉和脂肪面积。
  • TNC与VNC图像不应互换用于评估组织衰减或特定肌肉成分如LAMA或NAMA。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To determine whether virtual noncontrast (VNC) images derived from three-phase dynamic dual-energy CT (DECT) imaging can reliably substitute true noncontrast (TNC) images in assessing muscle and fat with automatic segmentation software.

MATERIALS AND METHODS: The data from 476 dynamic liver DECT examinations performed between April 2019 and December 2020 were retrospectively analyzed. VNC images were generated from arterial (VNCa), portal-venous (VNCp), and delayed (VNCd) phase images. Automated software measured muscle, visceral fat (VF), and subcutaneous fat (SF) areas. Sarcopenia was defined using muscle-related indices. Differences in muscle and fat measurements, as well as sarcopenia prevalence, between TNC and VNC images were assessed using paired t tests and McNemar tests, respectively.

RESULTS: The average age of the 476 patients (307 men) was 58.4±12.5years. Muscle density and area differed significantly between the TNC and VNC images; TNC images showed higher mean muscle density and smaller skeletal muscle area (SMA) than all VNC images (P<0.001). VF and SF attenuations were significantly lower on TNC images than on all VNC images (P<0.001). The proportions of sarcopenic patients did not differ significantly between TNC and VNCp or VNCd, regardless of the muscle index used.

CONCLUSION: Despite significant differences in muscle and fat attenuations between TNC and VNC images, VNCp and VNCd may be acceptable alternatives for measuring muscle and fat areas. However, TNC and VNC images should not be used interchangeably for assessing tissue attenuation or specific muscle components such as LAMA or NAMA.

来源:Acad Radiol,查看原文。版权归原作者所有。