单心室患者肝脏参数映射的外周与中心测量:测量位置至关重要
本研究为回顾性单中心队列研究,纳入68例单心室畸形患儿和25例健康对照,评估肝脏MRI参数映射外周与中心测量值的差异。结果显示测量位置影响T1、T2映射值,T1比值与T1均值强相关(r=0.68),T1比值在术后TCPC患者中最高,但其与血流动力学的关联弱于绝对值。
要点
- 肝脏MRI参数映射的测量位置(外周vs中心)显著影响T1、T2值,报告时应注明测量区域。
- TCPC术后患者T1、T2映射比值最高,且右叶T1、T2及ECV值显著高于左叶。
- T1比值与T1均值强相关(r=0.68),但与血流动力学关联弱于绝对值,绝对值在肝硬化各区域均显著升高。
核心结论
- 测量位置影响肝脏参数映射值;在外周-中心比值中,T1比值最有前景,但其与血流动力学的关联弱于绝对值。
研究设计与样本
- 回顾性单中心队列研究,纳入68例单心室畸形患儿和25例健康对照,在三个肝区域测量参数映射值,比较中央区与两叶外周区。
关键影像表现/征象
- TCPC术后患者右叶T1、T2映射及ECV值显著高于左叶(p<0.05)。
- 肝硬化患者所有测试区域的绝对T1值均显著升高(p<0.05)。
诊断标准与关键数值
- T1比值与T1均值强正相关(r=0.68,p<0.001),T2比值与T2均值中度正相关(r=0.46,p<0.001)。
临床应用与阅片要点
- 阅片报告肝脏参数映射时需注明测量位置(外周或中心),避免不同位置数值直接比较。
- 在TCPC术后患者中,右叶与左叶参数映射值存在差异,建议分别观察并记录。
局限性
- 原文为回顾性单中心队列研究,样本量有限(68例患儿和25例对照)。
- 原文结论指出T1比值与血流动力学的关联弱于绝对值,需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Fontan circulation often results in Fontan-associated liver disease, typically challenging to detect early. MRI liver parametric mapping shows potential for tissue characterization, but institution-specific reference values hinder comparability. This study investigates whether the peripheral-to-central mapping ratio can serve as a surrogate for absolute mapping values.
METHODS: The retrospective single tertiary center cohort study included 68 pediatric patients with single ventricle anomalies and 25 healthy controls. Parametric mapping values were measured in three liver regions, comparing central region and peripheral areas of both liver lobes.
RESULTS: There was a strong positive correlation between the T1 ratio and T1 mean (r = 0.68, p < 0.001), and a moderate positive correlation between the T2 ratio and T2 mean (r = 0.46, p < 0.001). T1 and T2 mapping ratios exhibited the highest values in post-total cavopulmonary connection (TCPC) patients (p < 0.05). Post-TCPC patients had significantly higher T1 and T2 mapping, and ECV values in the right lobe compared to the left lobe (p < 0.05). T1 mean showed significant weak associations with duration of post-TCPC follow-up (r = 0.3, p = 0.029), ejection fraction (r = -0.36, p = 0.006), oxygen saturation (r = -0.31, p = 0.022), and univentricular end-diastolic volume (r = 0.27, p = 0.043), and severe lymphatic collaterals were linked to higher T1 mean values (p = 0.024) in post-TCPC patients. Absolute T1 values were significantly higher in cirrhosis across all tested regions (p < 0.05). The T1 ratio was significantly associated with the duration of post-TCPC follow-up (r = 0.27, p = 0.041).
CONCLUSIONS: Measurement location influences liver parametric mapping values. The T1 ratio shows the most promise among the peripheral-to-central ratios, though its associations with hemodynamics are weaker than those of absolute values.
引用
- Yanovskiy A, Ojala T, Kormi A, et al. Peripheral vs. central parametric mapping of the liver in single ventricle patients: Measurement location matters. Eur J Radiol. 2025. PMID: 40334366. doi:10.1016/j.ejrad.2025.112158
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。