文献速递腹部介入CT

恶性肝肿瘤经皮热消融中定量消融确认方法:技术要点、临床证据与未来展望

Quantitative Ablation Confirmation Methods in Percutaneous Thermal Ablation of Malignant Liver Tumors: Technical Insights, Clinical Evidence, and Future Outlook.
PubMed 文献 · Radiol Imaging Cancer · 2025-01-01

本文综述经皮影像引导热消融治疗原发性和继发性恶性肝肿瘤时,最小消融边缘(MAM)的定量评估方法。作者讨论图像采集、分割、配准和MAM计算等技术环节,定义测量误差来源,描述现有软件方案,并指出当前临床证据强烈支持使用专用软件;最后讨论广泛应用的物流与财务障碍及潜在解决方案。

要点

  • MAM是热消融技术成功的关键指标,定义为肿瘤与消融区边缘之间的最小距离。
  • 传统定性评估MAM准确性及可重复性欠佳,易受操作者偏倚影响。
  • 基于软件的定量方法可标准化和自动化MAM量化,临床证据强烈支持使用专用软件。

核心结论

  • 定量消融确认软件方法可标准化和自动化MAM量化,当前临床证据强烈支持使用此类专用软件。

研究设计与样本

  • 综述;讨论定量消融确认方法的技术组成(图像采集、分割、配准、MAM计算)、测量误差来源、现有软件方案及临床证据。

临床应用与阅片要点

  • MAM是热消融技术成功的关键指标,定义为肿瘤与消融区边缘之间的最小距离。
  • 传统MAM评估依赖解剖标志定性判断,准确性和可重复性欠佳,易受操作者偏倚影响。
  • 专用软件可标准化和自动化MAM量化,临床证据强烈支持使用此类软件。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Percutaneous image-guided thermal ablation is an established local curative-intent treatment technique for the treatment of primary and secondary malignant liver tumors. Whereas margin assessment after surgical resection can be accomplished with microscopic examination of the resected specimen, margin assessment after percutaneous thermal ablation relies on cross-sectional imaging. The critical measure of technical success is the minimal ablative margin (MAM), defined as the minimum distance between the tumor and the edge of the ablation zone. Traditionally, the MAM has been assessed qualitatively using anatomic landmarks, which has suboptimal accuracy and reproducibility and is prone to operator bias. Consequently, specialized software-based methods have been developed to standardize and automate MAM quantification. In this review, the authors discuss the technical components of such methods, including image acquisition, segmentation, registration, and MAM computation, define the sources of measurement error, describe available software solutions in terms of image processing techniques and modes of integration, and outline the current clinical evidence, which strongly supports the use of such dedicated software. Finally, the authors discuss current logistical and financial barriers to widespread use of ablation confirmation methods as well as potential solutions. Keywords: Ablation Techniques, CT, Image Postprocessing, Liver Supplemental material is available for this article. © RSNA, 2025.

来源:Radiol Imaging Cancer,查看原文。版权归原作者所有。

引用

  1. Paolucci I, Albuquerque Marques Silva J, Lin YM, et al. Quantitative Ablation Confirmation Methods in Percutaneous Thermal Ablation of Malignant Liver Tumors: Technical Insights, Clinical Evidence, and Future Outlook. Radiol Imaging Cancer. 2025. PMID: 40314585. doi:10.1148/rycan.240293

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。