文献速递腹部技术与安全CTMR

基于CT和MRI的影像组学模型术前预测结直肠癌微卫星不稳定性:系统综述与Meta分析

Preoperative radiomics models using CT and MRI for microsatellite instability in colorectal cancer: a systematic review and meta-analysis.
PubMed 文献 · Abdom Radiol (NY) · 2025-05-10

该系统综述与Meta分析纳入17项研究共6045例受试者,评估基于CT和MRI的影像组学模型检测结直肠癌微卫星不稳定性状态的诊断性能。合并AUC在CT研究为0.815(95%CI:0.784-0.840),在MRI研究为0.900(95%CI:0.819-0.943),存在显著异质性并经广泛分析处理。作者认为影像组学模型是预测结直肠癌患者微卫星不稳定性状态的新颖且有前景的工具。

要点

  • MRI影像组学模型预测MSI的合并AUC为0.900(95%CI:0.819-0.943),CT模型为0.815(95%CI:0.784-0.840)。
  • 共纳入17项研究、6045例受试者,均从结直肠癌患者CT或MRI图像提取影像组学特征训练机器学习模型。
  • 纳入研究存在显著异质性,作者通过敏感性分析、阈值效应评估、亚组分析和Meta回归进行探索。

核心结论

  • 影像组学模型是预测结直肠癌患者MSI状态的新颖且有前景的工具,这些发现可能为未来开发和验证改进模型奠定基础,最终改善结直肠癌的诊断、治疗和预后。

研究设计与样本

  • 系统综述与Meta分析,系统检索PubMed、Embase、Cochrane Library和Scopus,纳入17项评估CT和MRI影像组学模型检测结直肠癌MSI状态诊断性能的研究,共6045例受试者,所有研究均从确诊MSI状态的结直肠癌患者CT或MRI图像提取影像组学特征训练机器学习模型,采用随机效应模型在RStudio中计算合并AUC、敏感度和特异度。

诊断标准与关键数值

  • CT影像组学研究的合并AUC为0.815(95%CI:0.784-0.840)。
  • MRI影像组学研究的合并AUC为0.900(95%CI:0.819-0.943)。

临床应用与阅片要点

  • 作者认为影像组学模型是预测结直肠癌患者MSI状态的新颖且有前景的工具,可能为未来开发和验证改进模型奠定基础。

局限性

  • 纳入研究存在显著异质性,作者通过敏感性分析、阈值效应评估、亚组分析和Meta回归进行广泛分析处理。
  • 作者指出这些发现可能为未来旨在开发和验证改进模型的研究奠定基础。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Microsatellite instability (MSI) is a novel predictive biomarker for chemotherapy and immunotherapy response, as well as prognostic indicator in colorectal cancer (CRC). The current standard for MSI identification is polymerase chain reaction (PCR) testing or the immunohistochemical analysis of tumor biopsy samples. However, tumor heterogeneity and procedure complications pose challenges to these techniques. CT and MRI-based radiomics models offer a promising non-invasive approach for this purpose.

MATERIALS AND METHODS: A systematic search of PubMed, Embase, Cochrane Library and Scopus was conducted to identify studies evaluating the diagnostic performance of CT and MRI-based radiomics models for detecting MSI status in CRC. Pooled area under the curve (AUC), sensitivity, and specificity were calculated in RStudio using a random-effects model. Forest plots and a summary ROC curve were generated. Heterogeneity was assessed using I² statistics and explored through sensitivity analyses, threshold effect assessment, subgroup analyses and meta-regression.

RESULTS: 17 studies with a total of 6,045 subjects were included in the analysis. All studies extracted radiomic features from CT or MRI images of CRC patients with confirmed MSI status to train machine learning models. The pooled AUC was 0.815 (95% CI: 0.784-0.840) for CT-based studies and 0.900 (95% CI: 0.819-0.943) for MRI-based studies. Significant heterogeneity was identified and addressed through extensive analysis.

CONCLUSION: Radiomics models represent a novel and promising tool for predicting MSI status in CRC patients. These findings may serve as a foundation for future studies aimed at developing and validating improved models, ultimately enhancing the diagnosis, treatment, and prognosis of colorectal cancer.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Capello Ingold G, Martins da Fonseca J, Kolenda Zloić S, et al. Preoperative radiomics models using CT and MRI for microsatellite instability in colorectal cancer: a systematic review and meta-analysis. Abdom Radiol (NY). 2025. PMID: 40347255. doi:10.1007/s00261-025-04981-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。