文献速递腹部CT

低渗对比剂标记在最低限度肠道准备CT结肠成像结直肠癌筛查中的观察性研究

Low-osmolar contrast tagging in minimally cathartic CT colonography for colorectal cancer screening: an observational study.
PubMed 文献 · Abdom Radiol (NY) · 2025-05-15

前瞻性观察性研究纳入50例受试者,口服50 mL碘海醇标记联合10盎司枸橼酸镁行最低限度肠道准备后行CT结肠成像,47例成功完成。残留液体节段中73.6%标记良好,平均液体标记效能比为0.737(95%CI 0.700-0.775),平均衰减为467 HU;标记效能从盲肠(0.934)向直肠(0.493)递减。作者结论认为低容量(50 mL)碘海醇是有效的液体和粪便标记剂。

要点

  • 残留液体节段中73.6%标记良好,平均标记效能比0.737(95%CI 0.700-0.775),平均衰减467 HU。
  • 液体标记效能从盲肠0.934递减至直肠0.493,阅片时需注意远端结肠标记效能较低。
  • 92.8%的结肠节段无残留固体粪便,仅7.2%节段含固体粪便。

核心结论

  • 低容量(50 mL)碘海醇是CT结肠成像联合最低限度肠道准备时有效的液体和粪便标记剂,为标记残留物质和清洁肠道提供了简便选择。

研究设计与样本

  • 前瞻性观察性研究,50例受试者口服50 mL碘海醇标记并联用10盎司枸橼酸镁行肠道准备,其中47例成功完成CT结肠成像;由两名委员会认证的腹部放射科医生独立对6个结肠节段进行评分。

关键影像表现/征象

  • 1252个结肠节段中14.8%无残留液体,59.5%残留液体小于25%。
  • 有残留液体的节段中73.6%显示良好标记,全部节段平均液体标记效能比为0.737(95%CI 0.700-0.775),平均衰减为467 HU。
  • 液体标记效能从盲肠的0.934下降至直肠的0.493。
  • 92.8%的节段无残留固体粪便;含固体粪便的7.2%节段中,4.7%为淹没的粪便≤5 mm,0.8%为6至9 mm的残留粪便1至3块,1.8%为6至9 mm超过3块或单块大于1 cm。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Adequate bowel preparation and tagging are critical in optimizing CTC performance. Iohexol has a higher safety profile than other available tagging agents. This study aims to determine if iohexol serves as an adequate fluid and stool tagging agent in conjunction with minimally cathartic bowel preparation.

METHODS: In this prospective observational study, 50 participants ingested 50 mL of oral iohexol for tagging and 10 oz magnesium citrate for bowel preparation prior to CTC. Written informed consent was obtained. CTC was performed in all participants in at least two of the standard four positions (supine, prone, right decubitus, and left decubitus). Two board-certified abdominal radiologists independently scored the 6 colonic segments of participants who underwent successful CTC. The amount of residual fluid and solid stool, attenuation of tagged fluid, and efficacy of fluid and stool tagging were recorded in each segment. Statistical analyses were performed with R-4.4.0.

RESULTS: 47 participants (mean age 66.39 ± 8.65 years; 39 female) underwent successful CTC. Of 1252 total colonic segments, 14.8% had no residual fluid and 59.5% had < 25% residual fluid. 73.6% of segments with residual fluid demonstrated good tagging. The mean fluid tagging efficacy ratio for all segments was 0.737 (95% CI: 0.700-0.775) with mean attenuation of 467 HU. Fluid tagging efficacy decreased from the cecum (0.934) to rectum (0.493). 92.8% of segments had no residual solid stool. Of the 7.2% of segments containing solid stool, 4.7% of segments had submerged stool ≤ 5 mm, 0.8% had 1-3 pieces of retained stool between 6 and 9 mm, and 1.8% had > 3 pieces 6-9 mm or single pieces > 1 cm.

CONCLUSION: Low-volume (50 mL) iohexol is an effective fluid and fecal tagging agent for CTC with a minimally cathartic bowel preparation. This provides an easy option to label residual material and cleanse the bowel for patients undergoing CTC.