文献速递腹部技术与安全CT

甘露醇准备CT结肠成像检测梗阻性结直肠癌同步病变的准确性

Accuracy of CT colonography with mannitol preparation for detecting synchronous lesions in obstructive colorectal cancer.
PubMed 文献 · Eur J Radiol · 2025-05-05

回顾性分析62例梗阻性结直肠癌且结肠镜不完整患者的甘露醇准备CT结肠成像,以术后手术病理及随访结肠镜为参考,≥6 mm同步病变敏感度92.3%、特异度99.1%、阳性预测值88.9%、阴性预测值99.4%,肠道清洁充分。

要点

  • ≥6 mm同步病变敏感度92.3%、特异度99.1%,阴性预测值99.4%。
  • 82.8%肠段无或仅少量残留液体,96.3%无或仅少量固体残留。
  • 作者认为甘露醇准备是聚乙二醇的可行替代,可能改善耐受性。

核心结论

  • 甘露醇准备CT结肠成像在梗阻性结直肠癌且结肠镜不完整患者中检测同步肿瘤准确性高,作者认为甘露醇是聚乙二醇的可行替代,可能改善耐受性。

研究设计与样本

  • 回顾性分析150例结肠镜不完整并行甘露醇准备术前CT结肠成像的结直肠癌患者中的62例,以术后手术病理及随访结肠镜为参考标准。

关键影像表现/征象

  • 62例共372个肠段中识别26个同步病变,其中9个≥10 mm、17个6-9 mm。
  • 82.8%肠段无或仅少量残留液体,96.3%肠段无或仅少量固体残留。

诊断标准与关键数值

  • ≥6 mm病变:敏感度92.3%(95%CI 74.9-99.1%)。
  • ≥6 mm病变:特异度99.1%(95%CI 97.5-99.8%)。
  • ≥6 mm病变:阳性预测值88.9%(95%CI 70.8-97.6%)。
  • ≥6 mm病变:阴性预测值99.4%(95%CI 97.9-99.9%)。

临床应用与阅片要点

  • 作者认为甘露醇准备CT结肠成像可用于梗阻性结直肠癌且结肠镜不完整患者的同步病变检测。
  • 作者认为甘露醇是聚乙二醇的可行替代,可能改善耐受性。
  • 作者认为该检查可能简化手术规划并改善现代结直肠癌管理的总体结局。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Preoperative detection of advanced neoplasms is essential for surgical planning in colorectal cancer (CRC). CT colonography (CTC) has emerged as a reliable alternative when obstructive CRC prevents complete optical colonoscopy (OC). Mannitol, commonly used for OC preparation in some countries, offers potential advantages over polyethylene glycol (PEG), including low cost, reduced ingestion volume, fast action, and a more palatable sweet taste. We evaluated the diagnostic accuracy of mannitol-based CTC for detecting synchronous lesions in CRC, hypothesizing that this low-volume preparation could maintain high accuracy while improving patient tolerability.

METHODS: Of 150 CRC patients with incomplete OC who underwent preoperative CTC following cathartic preparation with mannitol, 62 were retrospectively analyzed. Their CTC findings were compared with postoperative surgical and pathological results and follow-up OC. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were assessed for lesions ≥6 mm. In addition, the quality of bowel preparation with mannitol (amount of liquid and solid residue) was compared with historical data from published studies.

RESULTS: In 62 patients (372 segments), 26 synchronous lesions were identified (9 ≥ 10 mm, 17 sized 6-9 mm). For lesions ≥6 mm, CTC achieved a sensitivity of 92.3 % (95 % CI: 74.9-99.1 %), specificity of 99.1 % (95 % CI: 97.5-99.8 %), PPV of 88.9 % (95 % CI: 70.8-97.6 %), and NPV of 99.4 % (95 % CI: 97.9-99.9 %). Bowel cleansing was adequate, with 82.8 % of segments showing no or minimal residual fluid and 96.3 % with no or minimal solid residue.

CONCLUSION: CTC with a mannitol-based preparation demonstrated high accuracy in detecting synchronous neoplasms among patients with obstructive CRC and incomplete OC. These findings suggest that mannitol is a feasible alternative to PEG, maintaining excellent diagnostic performance while possibly improving tolerability. Additionally, it could streamline surgical planning and improve overall outcomes in modern CRC management.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Caiado AHM, Nahas SC, Oliveira IRS, et al. Accuracy of CT colonography with mannitol preparation for detecting synchronous lesions in obstructive colorectal cancer. Eur J Radiol. 2025. PMID: 40344713. doi:10.1016/j.ejrad.2025.112151

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。