本研究利用深度学习技术构建肝纤维化无创分期模型,基于超声获取的纯肝实质图像,结合经皮肝穿刺活检结果判断纤维化程度,创新性引入纤维化对比层(FCL)和标签融合(LF)策略。模型准确率达85.6%,优于ResNet(81.9%)、InceptionNet(80.9%)和VGG(80.8%);在仅30%数据的小样本条件下仍保持84.8%的准确率,稳定性优于传统深度学习模型。

要点

  • FCLLF模型基于超声纯肝实质图像实现肝纤维化无创分期,准确率85.6%。
  • 在30%小样本数据下准确率仍达84.8%,优于传统深度学习模型。
  • 纤维化对比层(FCL)帮助模型捕捉各级别肝纤维化特征的显著差异。

核心结论

  • FCLLF模型在全体样本和30%小样本训练环境下测试性能均优于VGG、ResNet、InceptionNet等传统深度学习模型,性能更稳定,尤其在小样本数据集环境下,有效提高了无创超声成像肝纤维化分期的准确性和稳定性。

研究设计与样本

  • 采用深度学习技术构建肝纤维化诊断模型,使用超声检查获取纯肝实质图像截面数据,经患者同意后结合经皮肝穿刺活检结果判断纤维化程度,引入纤维化对比层(FCL)和标签融合(LF)。

诊断标准与关键数值

  • FCLLF模型准确率85.6%,ResNet准确率81.9%,InceptionNet准确率80.9%,VGG准确率80.8%。
  • 在30%小样本数据条件下,FCLLF模型准确率84.8%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The diagnosis of liver fibrosis is usually based on histopathological examination of liver puncture specimens. Although liver puncture is accurate, it has invasive risks and high economic costs, which are difficult for some patients to accept. Therefore, this study uses deep learning technology to build a liver fibrosis diagnosis model to achieve non-invasive staging of liver fibrosis, avoid complications, and reduce costs.

METHODS: This study uses ultrasound examination to obtain pure liver parenchyma image section data. With the consent of the patient, combined with the results of percutaneous liver puncture biopsy, the degree of liver fibrosis indicated by ultrasound examination data is judged. The concept of Fibrosis Contrast Layer (FCL) is creatively introduced in our experimental method, which can help our model more keenly capture the significant differences in the characteristics of liver fibrosis of various grades. Finally, through label fusion (LF), the characteristics of liver specimens of the same fibrosis stage are abstracted and fused to improve the accuracy and stability of the diagnostic model.

RESULTS: Experimental evaluation demonstrated that our model achieved an accuracy of 85.6%, outperforming baseline models such as ResNet (81.9%), InceptionNet (80.9%), and VGG (80.8%). Even under a small-sample condition (30% data), the model maintained an accuracy of 84.8%, significantly outperforming traditional deep-learning models exhibiting sharp performance declines.

CONCLUSION: The training results show that in the whole sample data set and 30% small sample data set training environments, the FCLLF model's test performance results are better than those of traditional deep learning models such as VGG, ResNet, and InceptionNet. The performance of the FCLLF model is more stable, especially in the small sample data set environment. Our proposed FCLLF model effectively improves the accuracy and stability of liver fibrosis staging using non-invasive ultrasound imaging.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。