心脏磁共振应变测量对肥厚型心肌病患者不良事件的预测价值:一项多参数回顾性队列研究
回顾性分析221例确诊肥厚型心肌病患者的CMR与临床资料,中位随访25.8个月,60例(27.1%)发生联合终点事件。多因素Cox回归显示左室整体纵向应变(GLS)和整体径向应变(GRS)是最稳健的预测因子,GLS≥-12.96%预测不良事件的敏感度78%、特异度76%(AUC=0.81,P<0.001)。
要点
- 左室GLS≥-12.96%预测HCM不良事件敏感度78%、特异度76%,AUC=0.81(P<0.001)
- 221例中60例(27.1%)随访期间发生联合终点事件,中位随访25.8个月
核心结论
- 多种CMR参数可预测HCM患者不良事件,其中特征追踪CMR测得的左室GLS和GRS是最稳健的预测因子。
研究设计与样本
- 回顾性队列研究,纳入221例确诊肥厚型心肌病患者,评估CMR与临床资料,中位随访25.8个月(四分位距23.7个月),终点为心源性猝死、幸免的心源性猝死、植入型心律转复除颤器植入及左室收缩功能恶化的联合终点,采用t检验比较组间差异、Cox比例风险回归分析预测价值、ROC曲线确定最佳截断值。
诊断标准与关键数值
- 左室整体纵向应变(GLS)≥-12.96%预测不良事件:敏感度78%、特异度76%、AUC=0.81(P<0.001)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: We aimed to investigate the role of cardiac magnetic resonance (CMR) imaging parameters, especially strain values, in predicting adverse events in patients with hypertrophic cardiomyopathy (HCM).
MATERIALS AND METHODS: CMR and clinical data of 221 definite cases of HCM were evaluated retrospectively. A combined outcome, comprising sudden cardiac death (SCD), aborted SCD, the insertion of an implantable cardioverter-defibrillator (ICD), and the deterioration of left ventricular (LV) systolic function, was registered during a median (interquartile range) follow-up time of 25.8 (23.7) months. Intergroup differences were estimated utilizing a t test, and the predictive values of variables were investigated using the Cox proportional hazard regression analysis. The receiver operating curve analysis demonstrated the best cutoff value for potent predictors.
RESULTS: Sixty (27.1%) out of the 221 patients (mean±SD age =44.58±16.85 y, 131 men) demonstrated endpoints on follow-up. Multiple CMR parameters predicted adverse events in the univariate analysis. LV global longitudinal and radial strain (GLS and GRS) values were the most robust predictors in the multivariate Cox regression analysis (HR [confidence interval], 1.26 [1.16 to 1.36] and 1.02 [1.00 to 1.04], respectively; P<0.05). LV GLS ≥ -12.96% predicted adverse events with a sensitivity of 78% and a specificity of 76% (area under the curve =0.81; P<0.001).
CONCLUSION: Multiple CMR parameters predicted adverse events in HCM patients, with feature tracking-CMR values, LV GLS, and LV GRS being the most robust predictors.
引用
- Rezaeian N, Heidari Bakavoli A, Dastmardi M, et al. The Value of Cardiac MRI Strain Measures in Predicting Adverse Events in Hypertrophic Cardiomyopathy Patients: A Multiparametric Retrospective Cohort Study. Acad Radiol. 2025. PMID: 40328539. doi:10.1016/j.acra.2025.04.043
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。