超高分辨率光子计数探测器冠状动脉CT较有创参考标准可最小化高估偏倚
回顾性纳入49例疑似冠心病患者,在光子计数探测器CT上行超高分辨率冠状动脉CT血管成像,分别以0.6 mm、0.4 mm和0.2 mm层厚重建,并与有创定量冠状动脉造影对照。结果显示随空间分辨率提高,狭窄直径均值下降、CCTA与QCA间偏倚减小,超高分辨率重建对≥50%狭窄的诊断准确度和阳性预测值优于较低分辨率。
要点
- 0.6 mm、0.4 mm、0.2 mm重建的狭窄直径均值分别为61.4%、55.3%、50.9%,随分辨率提高而下降。
- CCTA与QCA间偏倚随分辨率提高而减小:0.6 mm为13.2%(LoA 30),0.4 mm为9.4%(LoA 28.1),0.2 mm为5.2%(LoA 23)。
- 超高分辨率0.2 mm重建对≥50%狭窄的诊断准确度71.4%、PPV 61.8%,优于0.6 mm和0.4 mm重建。
核心结论
- 光子计数探测器CT超高分辨率冠状动脉CT血管成像可减小对狭窄程度的高估偏倚并提高阳性预测值。
研究设计与样本
- 回顾性研究,纳入49例(71±9岁,37%男性)疑似冠心病且UHR-CCTA显示冠状动脉狭窄并临床指示后续有创冠状动脉造影、无既往冠状动脉介入的患者;采用光子计数探测器CT系统,分别以0.6 mm、0.4 mm和UHR 0.2 mm层厚重建,以有创定量冠状动脉造影(QCA)为参考标准。
诊断标准与关键数值
- 以QCA证实的相关冠状动脉狭窄(≥50%)为诊断目标;103个节段的狭窄直径均值:0.6 mm重建61.4%、0.4 mm重建55.3%、UHR 0.2 mm重建50.9%(p≤0.001)。CCTA与QCA间偏倚:0.6 mm为13.2%(一致性界限30),0.4 mm为9.4%(一致性界限28.1),UHR 0.2 mm为5.2%(一致性界限23)。诊断准确度:0.6 mm 61.2%、0.4 mm 61.2%、UHR 0.2 mm 71.4%;阳性预测值:0.6 mm 53.7%、0.4 mm 53.9%、UHR 0.2 mm 61.8%。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Photon-counting detector (PCD) coronary CT angiography (CCTA) at ultra-high-resolution (UHR) is a promising tool for the detailed evaluation of the coronary arteries. However, correlation with invasive quantitative coronary angiography (QCA) has not been thoroughly investigated. We here evaluated the efficacy of UHR-CCTA against invasive QCA in patients suspected of coronary artery disease (CAD).
METHODS: Retrospectively, patients suggestive of CAD were included if they had undergone UHR-CCTA on a PCD-CT system showing coronary stenosis which clinically indicated subsequent invasive coronary angiography and no prior coronary interventions. CCTA datasets were reconstructed in 0.6 mm, 0.4 mm, and UHR 0.2 mm slice thicknesses. The extent of stenosis was compared between QCA and CCTA using univariate analysis of variance with post-hoc testing and Bland-Altman plots. Diagnostic performance was assessed based on the detection of relevant coronary stenosis (≥50 %) as confirmed by QCA.
RESULTS: Forty-nine patients (71 ± 9 years; 37 % male) were included. Stenosis evaluation for 103 segments revealed decreasing mean stenosis diameter with improving spatial resolution (61.4 % for 0.6 mm, 55.3 % for 0.4 mm, 50.9 % for UHR 0.2 mm; p ≤ 0.001). Bias between CCTA and QCA decreased with increasing resolution (13.2 %, limits of agreement [LoA] 30 vs. 9.4 %, 28.1 vs. 5.2 %, 23). UHR-CCTA reconstructions showed superior diagnostic accuracy and positive predictive value (PPV) for detecting relevant CAD compared to lower resolutions (61.2 vs. 61.2 % vs. 71.4 and 53.7 % vs. 53.9 vs. 61.8 %, respectively).
CONCLUSIONS: UHR-CCTA with photon-counting detector CT demonstrated a decrease in overestimation bias and an increase in PPV.