一种用于胎儿主动脉三维血流动力学建模的新型产前流程
研究旨在利用标准2D胎儿超声心动图构建搏动性三维主动脉模型,以补充先天性心脏病诊断中的血流动力学信息。方法采用边缘检测算法勾画血管边界,将主动脉弓及分支中心线横截面直径整合入三维几何模型并用SimVascular重建,对3例假阳性主动脉缩窄胎儿和3例真阳性主动脉缩窄胎儿(出生后确诊)进行患者特异性模拟。结果显示该流程可生成生理上合理且交叉验证的胎儿血流动力学量化结果,包括无创预测的胎儿主动脉压力、流线及血管位移。
要点
- 提出从标准2D胎儿超声心动图生成胎儿主动脉搏动性三维血流动力学模型的流程。
- 该流程可无创预测胎儿主动脉压力、流线及血管位移,补充形态学信息。
- 在3例假阳性和3例真阳性主动脉缩窄胎儿中进行了患者特异性模拟。
核心结论
- 该流程可生成捕捉流固相互作用的胎儿主动脉血流模拟,并提供此前产前无法获得的无创血流动力学指标预测,可能提高先天性心脏病的诊断精确度。
研究设计与样本
- 方法学研究,利用2D胎儿超声心动图进行边缘检测和血管边界勾画,将主动脉弓及分支中心线横截面直径整合入三维几何模型并用SimVascular重建;对3例假阳性主动脉缩窄胎儿和3例真阳性主动脉缩窄胎儿(出生后确诊)构建患者特异性模拟,使用超声心动图和多普勒源数据。
临床应用与阅片要点
- 作者认为该流程可整合入临床诊断,提供超越心脏形态可视化的患者特异性生理信息,可能提高先天性心脏病的诊断精确度。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Congenital heart disease (CHD) is the most common birth defect and the leading cause of infant death from congenital anomalies. Limitations in standard-of-care fetal echocardiography lack hemodynamic insight. Cardiovascular computational modeling methods have been developed to simulate patient-specific morphology and hemodynamics, but are limited in applications for fetal diagnosis, as existing pipelines depend upon 3D CMR imaging data. There is no existing workflow for converting 2D echocardiograms into models of the fetal aorta. We aim to develop a methodology to create pulsatile 3D-aortic models from standard-of-care 2D echocardiograms to supplement fetal imaging with noninvasive predictions of hemodynamics in CHD diagnosis.
METHODS: Utilizing 2D fetal echocardiograms, edge detection algorithms are applied to delineate vessel boundaries. Cross-sectional diameters along the aortic arch and branch centerlines were segmented, integrated into 3D geometric models, and reconstructed using SimVascular. Patient-specific simulations were developed for three false-positive coarctation of the aorta (CoA) fetuses and 3 true positive CoA fetuses (postnatally confirmed), using echocardiogram and Doppler source data.
RESULTS: We propose a modeling methodology and set of boundary conditions that generate physiologically reasonable and cross-validated quantifications of fetal hemodynamics. Noninvasive predictions of fetal aortic pressures, flow streamlines, and vessel displacement offer insight into real-time hemodynamics and the stress of abnormal morphology on flow directions in the prenatal aorta.
CONCLUSIONS: We present a clinically useful pipeline for generating simulations of flow in the fetal aorta that capture fluid-structure interactions and generate noninvasive predictions of diagnostic hemodynamic indicators that could not previously be captured prenatally. This pipeline integrates into clinical diagnosis and offers insight into patient-specific physiology beyond a visualization of cardiac morphology alone, offering the potential to enhance the diagnostic precision of CHDs.
引用
- Sarsam J, Desmond A, Roustaei M, et al. A Novel Prenatal Pipeline for Three-Dimensional Hemodynamic Modeling of the Fetal Aorta. J Ultrasound Med. 2025. PMID: 40434286. doi:10.1002/jum.16721
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。