文献速递心血管CT

高分辨率深度学习重建提高CT血流储备分数诊断准确性

High-resolution deep learning reconstruction to improve the accuracy of CT fractional flow reserve.
PubMed 文献 · Eur Radiol · 2025-05-22

本研究为单中心回顾性研究,纳入79例(98支血管)于2022年2月至2024年3月行冠状动脉CT血管成像后接受有创FFR检查的患者,比较基于模型迭代重建(MBIR)与高分辨率深度学习重建(HR-DLR)图像计算CT-FFR的诊断性能。以有创FFR≤0.80为功能性显著狭窄标准,HR-DLR的AUC为0.88,高于MBIR的0.76(p=0.003),诊断准确率88%对70%(p<0.001)。

要点

  • HR-DLR图像噪声低于MBIR(14.4±1.7 vs 23.5±3.1,p<0.001)。
  • HR-DLR的CT-FFR诊断功能性显著狭窄的AUC为0.88,高于MBIR的0.76(p=0.003)。
  • HR-DLR诊断准确率为88%(86/98血管),高于MBIR的70%(69/98血管,p<0.001)。

核心结论

  • HR-DLR可改善图像质量,并提高CT-FFR对功能性显著狭窄的诊断性能。

研究设计与样本

  • 单中心回顾性研究,纳入79例连续患者(平均年龄70±11岁,57例男性),共98支血管;于2022年2月至2024年3月行冠状动脉CT血管成像后接受有创FFR检查;CT-FFR采用无网格仿真计算;以有创FFR≤0.80为功能性显著狭窄参考标准;比较MBIR与HR-DLR图像。

关键影像表现/征象

  • HR-DLR的平均噪声为14.4±1.7,低于MBIR的23.5±3.1(p<0.001)。

诊断标准与关键数值

  • 功能性显著狭窄定义为有创FFR≤0.80;98支血管中46支(47%)存在功能性显著狭窄,平均有创FFR为0.81±0.09。
  • HR-DLR诊断功能性显著狭窄的AUC为0.88(95%CI:0.80,0.95),高于MBIR的0.76(95%CI:0.67,0.86;p=0.003)。
  • HR-DLR的诊断准确率为88%(86/98血管;95%CI:80,94),高于MBIR的70%(69/98血管;95%CI:60,79;p<0.001)。

临床应用与阅片要点

  • 作者结论认为HR-DLR可提高CT-FFR诊断功能性显著狭窄的诊断性能。
  • 作者指出HR-DLR可能进一步增强CT-FFR在诊断冠状动脉狭窄功能意义方面的临床效用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to compare the diagnostic performance of CT-derived fractional flow reserve (CT-FFR) using model-based iterative reconstruction (MBIR) and high-resolution deep learning reconstruction (HR-DLR) images to detect functionally significant stenosis with invasive FFR as the reference standard.

MATERIALS AND METHODS: This single-center retrospective study included 79 consecutive patients (mean age, 70 ± 11 [SD] years; 57 male) who underwent coronary CT angiography followed by invasive FFR between February 2022 and March 2024. CT-FFR was calculated using a mesh-free simulation. The cutoff for functionally significant stenosis was defined as FFR ≤ 0.80. CT-FFR was compared with MBIR and HR-DLR using receiver operating characteristic curve analysis.

RESULTS: The mean invasive FFR value was 0.81 ± 0.09, and 46 of 98 vessels (47%) had FFR ≤ 0.80. The mean noise of HR-DLR was lower than that of MBIR (14.4 ± 1.7 vs 23.5 ± 3.1, p < 0.001). The area under the receiver operating characteristic curve for the diagnosis of functionally significant stenosis of HR-DLR (0.88; 95% CI: 0.80, 0.95) was higher than that of MBIR (0.76; 95% CI: 0.67, 0.86; p = 0.003). The diagnostic accuracy of HR-DLR (88%; 86 of 98 vessels; 95% CI: 80, 94) was higher than that of MBIR (70%; 69 of 98 vessels; 95% CI: 60, 79; p < 0.001).

CONCLUSIONS: HR-DLR improves image quality and the diagnostic performance of CT-FFR for the diagnosis of functionally significant stenosis.

KEY POINTS: Question The effect of HR-DLR on the diagnostic performance of CT-FFR has not been investigated. Findings HR-DLR improved the diagnostic performance of CT-FFR over MBIR for the diagnosis of functionally significant stenosis as assessed by invasive FFR. Clinical relevance HR-DLR would further enhance the clinical utility of CT-FFR in diagnosing the functional significance of coronary stenosis.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Tomizawa N, Fan R, Fujimoto S, et al. High-resolution deep learning reconstruction to improve the accuracy of CT fractional flow reserve. Eur Radiol. 2025. PMID: 40402290. doi:10.1007/s00330-025-11707-w