主动脉弓近端锚定区圆周衍生直径与横径的变异比较

Comparison of variation in circumference derived diameter and transverse diameter at proximal landing zone of aortic arch.
PubMed 文献 · Br J Radiol · 2025-01-01

回顾性纳入50例TEVAR患者,在正交于中心线的曲面平面测量近端锚定区主动脉壁圆周并计算圆周衍生直径(CDD),与横断面(轴位)平面测量的横径(TD)比较。Bland-Altman分析显示两方法主效应及观察者简单效应均无统计学差异(P > .05),但7/37(18.9%)患者CDD与TD平均差值>3 mm。CDD观察者内和观察者间变异的一致性均显著(P > .05),TD在两项变异测试中绝对平均差值均大于CDD。作者认为CDD是TEVAR术前测量主动脉几何的潜在替代参数,重复性更高、观察者内和观察者间变异更小。

要点

  • CDD在正交于中心线的曲面平面测量,TD在横断面(轴位)平面测量。
  • 7/37(18.9%)患者CDD与TD平均差值>3 mm(市售支架常规尺寸间隔)。
  • TD观察者内和观察者间绝对平均差值均大于CDD。

核心结论

  • 结合当前临床实践要求和可用支架规格,CDD是TEVAR术前测量主动脉几何的潜在替代参数,重复性更高、观察者内和观察者间变异更小。

研究设计与样本

  • 回顾性纳入本中心2016年6月至2017年7月行TEVAR的50例患者,在正交于中心线的曲面平面测量近端锚定区主动脉壁圆周并计算CDD,在横断面(轴位)平面测量TD,3名观察者间隔1个月独立测量每例患者的CDD和TD各两次,采用统计学方法分析变异和重复性。

诊断标准与关键数值

  • Bland-Altman图显示两方法主效应及每名观察者的简单效应均无统计学差异(P > .05)。
  • 7/37(18.9%)患者CDD与TD平均差值>3 mm(市售支架常规尺寸间隔)。
  • CDD观察者内和观察者间变异的一致性均显著(P > .05)。
  • TD观察者内绝对平均差值-0.210 ± 0.776 mm vs CDD 0.014 mm ± 0.291,P < .0056。
  • TD观察者间绝对平均差值0.578 ± 0.382 mm vs CDD 0.188 ± 0.143 mm,P < .001。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: We proposed a parameter, the circumference derived diameter (CDD), to size the stent-graft implanted in the thoracic endovascular aortic repair (TEVAR), and evaluated the variation and repeatability compared with the transverse diameter (TD) measured in the cross-sectional (axial) plane of computed tomography angiography (CTA).

METHODS: Fifty patients undergoing TEVAR in our centre from June 2016 to July 2017 were enrolled retrospectively. The circumference of the aortic wall at the proximal landing zone (PLZ) was measured on the segment plane orthogonal to the centreline. The TD of the aortic wall at PLZ was measured in the cross-sectional (axial) plane. Three observers independently measured both CDD and TD for each patient twice with the interval of a month. The statistics was used to investigate the variation and repeatability of CDD and TD.

RESULTS: Bland-Altman plot exhibited no statistical difference in terms of main effects of both methods and simple effects of each observer (P > .05), whereas mean difference of > 3 mm (the general size interval of off-the-shelf stent-grafts) between CDD and TD was observed in 7/37 (18.9%) patients. CDD exhibited a significant consistency in both intra-observer and inter-observer variability (P > .05). Whereas, TD exhibited greater absolute mean differences than CDD in both variability tests (intra-observer: -0.210 ± 0.776 mm vs 0.014 mm ± 0.291, P < .0056; inter-observer: 0.578 ± 0.382 mm vs 0.188 ± 0.143 mm, P < .001).

CONCLUSIONS: Combining with the requirement of current clinical practice and available stent-graft specifications, CDD was a potential substitute parameter for sizing aortic geometry before TEVAR, with higher repeatability and less intra-observer and inter-observer variability.

ADVANCES IN KNOWLEDGE: We propose a parameter, CDD which has the potential to be a substitute parameter to size the stent-graft precisely before TEVAR.