文献速递胸部MR

使用二值阈值、高斯线性分箱和K均值方法定量129Xe MRI通气缺陷百分比:哮喘与COPD的差异

Quantification of 129Xe MRI Ventilation-defect-percent Using Binary-threshold, Gaussian Linear-Binning and K-means Methods: Differences in Asthma and COPD.
PubMed 文献 · Acad Radiol · 2025-05-05

该研究回顾性分析175例参与者(42例健康、43例COPD、90例哮喘)的超极化129Xe MRI数据,比较四种通气缺陷百分比(VDP)定量方法。结果显示GLB和BT法计算的VDP显著低于GLBslice和k-means法(p<.001),且各方法与k-means相关性显著但Bland-Altman 95%一致性区间较宽。作者认为在多中心研究中需考虑不同方法导致的VDP差异。

要点

  • GLB和BT法VDP在哮喘和COPD中均显著低于GLBslice和k-means法(p<.001)。
  • 四种方法间VDP相关性显著,但与k-means的95%一致性区间较宽。
  • 多中心研究需考虑不同VDP定量方法导致的差异。

核心结论

  • 使用四种方法计算的哮喘和COPD患者VDP差异对于多中心研究具有重要意义。

研究设计与样本

  • 回顾性研究,纳入175例参与者(42例健康、43例COPD、90例哮喘),使用CNN共配准和分割流程以及GLB、GLBslice、BT和k-means四种VDP定量方法评估数据,采用线性回归和Bland-Altman图分析方法间相关性和一致性。

诊断标准与关键数值

  • VDP定义为未通气肺体积与胸腔体积的比值。
  • GLB法VDP:哮喘6±9%、COPD 7±7%;BT法VDP:哮喘6±7%、COPD 10±8%;GLBslice法VDP:哮喘12±13%、COPD 16±15%;k-means法VDP:哮喘12±12%、COPD 25±17%。
  • GLB与k-means相关性R2=.64(p<.001),GLBslice与k-means相关性R2=.84(p<.001),BT与k-means相关性R2=.84(p<.001)。
  • Bland-Altman 95%一致性区间:k-means与GLB/GLBslice在COPD为-6%/-1%:42%/23%,在哮喘为-5%/-10%:16%/10%;k-means与BT在COPD为-4%:36%,在哮喘为-6%:19%。

临床应用与阅片要点

  • VDP定量方法的选择可能影响哮喘和COPD患者通气缺陷的评估结果。
  • 在多中心研究中应考虑不同VDP定量方法之间的差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Hyperpolarized 129Xe magnetic resonance imaging (MRI) provides a way to quantify ventilation heterogeneity as ventilation defect percent (VDP), calculated as the volume of unventilated lung volume normalized to the thoracic cavity volume. Currently used methods for quantifying VDP include (1) binary signal-intensity thresholds (Binary-threshold, BT), (2) Gaussian transformation of signal-intensity histogram with standard deviation thresholds or Gaussian-linear-binning (GLB), and (3) iterative centroid-based clustering of the signal-intensity histogram (k-means). These methods have not been directly compared in patients with asthma and chronic obstructive pulmonary disease (COPD), in whom ventilation defects are hallmark findings. Our objective was to quantify and compare VDP using these four different methods.

PATIENTS AND METHODS: Data from 175 participants (n=42 healthy, n=43 COPD, n=90 asthma) were retrospectively evaluated using a CNN co-registration and segmentation pipeline and GLB, GLBslice, (slice-wise evaluation of GLB) BT and k-means VDP quantification methods. Linear-regression and Bland-Altman plots were used to quantify inter-method correlations and agreement.

RESULTS: VDP was significantly different using GLB (Asthma: 6±9%, COPD: 7±7%, p<.001) and BT (Asthma: 6±7%, COPD: 10±8%, p<.001) methods compared to GLBslice (Asthma: 12±13%, COPD: 16±15%, p<.001) and k-means (Asthma: 12±12%, COPD: 25±17%, p<.001). VDP calculated using GLB (R2=.64, p<.001), GLBslice (R2=.84, p<.001) and BT (R2=.84, p<.001) was significantly correlated with k-means VDP. Bland-Altman plots revealed wide 95% confidence intervals of agreement for k-means with GLB/GLBslice (COPD -6%/-1%: 42%/23%; asthma -5%/-10%:16%/10%) and BT (COPD -4%:36%; asthma -6%:19%).

CONCLUSION: VDP differences in patients with asthma and COPD calculated using four methods are important to consider for multi-center studies.

来源:Acad Radiol,查看原文。版权归原作者所有。