文献速递外周血管介入CT

胸部穿支(IMAP、LICAP、DICAP)用于穿支对穿支及穿支皮瓣:基于CT血管造影的定位与解剖分析

Thoracic perforators (IMAP, LICAP, DICAP) for P-to-P and perforator flaps - analysis of localization and anatomy using computed tomography angiography.
PubMed 文献 · Eur J Radiol · 2025-05-13

本研究回顾性分析150例疑似主动脉病变患者的非心电门控胸腹主动脉CTA,评估IMAP、LICAP和DICAP的检出率、数量、位置和直径;结果显示CTA能无创地在体显示这三类胸部穿支,并可能指导整形手术规划。

要点

  • CTA可检出IMAP(99%)、LICAP(91%)和DICAP(87%),并测量其数量、肋间位置和直径。
  • IMAP平均每例3.35±1.30支,位于第3.35±1.30肋间,直径1.41±0.35 mm。
  • LICAP和DICAP平均直径分别为1.26±0.30 mm和1.25±0.31 mm,位置分别在第9.83±1.41和第7.49±2.27肋间。

核心结论

  • CTA能够无创地在体对IMAP、LICAP和DICAP进行解剖定位,因此有潜力指导先进的整形外科手术。

研究设计与样本

  • 回顾性研究,纳入150例疑似主动脉病变患者(年龄67.3±15.11岁,男99例、女51例),分析非心电门控胸腹主动脉CTA,排除主动脉病变、严重硬化伪影、主动脉支架、全身水肿或其他胸壁病变。

关键影像表现/征象

  • IMAP在99%的患者中检出,平均每例3.35±1.30支,通常位于第3.35±1.30肋间,平均直径1.41±0.35 mm。
  • LICAP在91%的患者中检出,平均每例3.46±1.93支,位于第9.83±1.41肋间,平均直径1.26±0.30 mm。
  • DICAP在87%的患者中检出,平均每例2.71±1.64支,通常位于第7.49±2.27肋间,平均直径1.25±0.31 mm。

诊断标准与关键数值

  • IMAP检出率99%,平均数量3.35±1.30支/例,平均直径1.41±0.35 mm。
  • LICAP检出率91%,平均数量3.46±1.93支/例,平均直径1.26±0.30 mm。
  • DICAP检出率87%,平均数量2.71±1.64支/例,平均直径1.25±0.31 mm。

临床应用与阅片要点

  • 原文结论指出CTA有潜力指导先进的整形外科手术,未给出具体阅片或报告建议。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Perforator-to-perforator (P-to-P) free flaps and local to regional perforator flaps are increasingly important in thoracic reconstructive surgery. However, limited anatomical and imaging data on internal mammary (IMAPs), lateral (LICAPs), and dorsal intercostal artery perforators (DICAPs) hinder presurgical planning and clinical use. This study aimed to evaluate the feasibility of computed tomography angiography (CTA) for thoracic perforator mapping.

MATERIALS AND METHODS: Non-ECG triggered CTAs of the thoracoabdominal aorta of patients with suspected aortal pathology were retrospectively reviewed. After applying exclusion criteria (aortal pathology, major hardening artifacts, aortal stent prothesis, anasarca or other thoracic wall pathology), absolute count, localization and diameter of thoracic perforators were analyzed for 150 patients (age: 67.3 ± 15.11, m = 99, f = 51) using integrated imaging software.

RESULTS: Using CTA, IMAPs were detected in 99 % of patients, with a mean count of 3.35 ± 1.30 per patient, typically located in the 3.35 ± 1.30 intercostal space (ICS) and having a mean diameter of 1.41 ± 0.35 mm. LICAPs were present in 91 % of patients, averaging 3.46 ± 1.93 per patient, found in the 9.83 ± 1.41 ICS with a mean diameter of 1.26 ± 0.30 mm. DICAPs were identified in 87 % of patients, with an average of 2.71 ± 1.64 per patient, typically located in the 7.49 ± 2.27 ICS and having a mean diameter of 1.25 ± 0.31 mm.

CONCLUSIONS: CTA is capable of non-invasive in vivo anatomical mapping of IMAPs, LICAPs and DICAPs and thus has the potential to guide state-of-the-art plastic surgery.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Brandt J, Aitzetmüller-Klietz M, Heindel W, et al. Thoracic perforators (IMAP, LICAP, DICAP) for P-to-P and perforator flaps - analysis of localization and anatomy using computed tomography angiography. Eur J Radiol. 2025. PMID: 40381387. doi:10.1016/j.ejrad.2025.112162

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。