深度学习增强的超低电压(80 kV)胸部CT机会性骨质疏松筛查:初步研究

Deep Learning-enhanced Opportunistic Osteoporosis Screening in Ultralow-Voltage (80 kV) Chest CT: A Preliminary Study.
PubMed 文献 · Acad Radiol · 2025-05-02

本研究纳入987例同时行80 kV胸部CT与120 kV腰椎CT的患者,采用四种卷积神经网络对T12-L2椎体进行自动分割、感兴趣区提取和骨密度计算,以120 kV定量CT为标准参考。深度学习法所得骨密度与120 kV定量CT的相关性(R²=0.991-0.998)和一致性优于80 kV定量CT,检测骨质疏松和低骨量的AUC达0.997-1.000。

要点

  • 80 kV胸部CT经深度学习自动测算T12-L2骨密度,与120 kV定量CT相关性高(R²=0.991-0.998)。
  • 深度学习法检测骨质疏松和低骨量的AUC为0.997-1.000,与80 kV定量CT相当。
  • 深度学习法与120 kV定量CT的一致性优于80 kV定量CT。

核心结论

  • 深度学习方法可利用肺癌筛查所用的超低电压80 kV胸部CT实现全自动骨密度计算,用于机会性骨质疏松筛查具有高准确性。

研究设计与样本

  • 初步研究,纳入2024年1月至7月接受80 kV胸部CT和120 kV腰椎CT的987例患者,来自六台CT扫描仪,按561:177:112:137分为训练集、验证集、测试集1和测试集2;采用四种卷积神经网络(3D VB-Net和SCN用于自动分割,3D VB-Net用于感兴趣区提取,DenseNet和ResNet用于骨密度计算)对目标椎体(T12-L2)进行分析,以120 kV定量CT骨密度值为标准参考。

诊断标准与关键数值

  • 120 kV定量CT与80 kV卷积神经网络骨密度比较:R²=0.991-0.998(P<0.001),平均误差-1.36至1.62 mg/cm³,95%一致性界限-9.73至7.01 mg/cm³。
  • 120 kV定量CT与80 kV定量CT骨密度比较:R²=0.990-0.991(P<0.001),平均误差1.72至2.27 mg/cm³,95%一致性界限-5.71至10.19 mg/cm³。
  • 80 kV卷积神经网络检测骨质疏松和低骨量的AUC分别为0.997-1.000和0.998-1.000。
  • 80 kV定量CT检测骨质疏松和低骨量的AUC分别为0.997-0.998和0.997。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To explore the feasibility of deep learning (DL)-enhanced, fully automated bone mineral density (BMD) measurement using the ultralow-voltage 80 kV chest CT scans performed for lung cancer screening.

MATERIALS AND METHODS: This study involved 987 patients who underwent 80 kV chest and 120 kV lumbar CT from January to July 2024. Patients were collected from six CT scanners and divided into the training, validation, and test sets 1 and 2 (561: 177: 112: 137). Four convolutional neural networks (CNNs) were employed for automated segmentation (3D VB-Net and SCN), region of interest extraction (3D VB-Net), and BMD calculation (DenseNet and ResNet) of the target vertebrae (T12-L2). The BMD values of T12-L2 were obtained using 80 and 120 kV quantitative CT (QCT), the latter serving as the standard reference. Linear regression and Bland-Altman analyses were used to compare BMD values between 120 kV QCT and 80 kV CNNs, and between 120 kV QCT and 80 kV QCT. Receiver operating characteristic curve analysis was used to assess the diagnostic performance of the 80 kV CNNs and 80 kV QCT for osteoporosis and low BMD from normal BMD.

RESULTS: Linear regression and Bland-ltman analyses revealed a stronger correlation (R2=0.991-0.998 and 0.990-0.991, P<0.001) and better agreement (mean error, -1.36 to 1.62 and 1.72 to 2.27 mg/cm3; 95% limits of agreement, -9.73 to 7.01 and -5.71 to 10.19mg/cm3) for BMD between 120 kV QCT and 80 kV CNNs than between 120 kV QCT and 80 kV QCT. The areas under the curve of the 80 kV CNNs and 80 kV QCT in detecting osteoporosis and low BMD were 0.997-1.000 and 0.997-0.998, and 0.998-1.000 and 0.997, respectively.

CONCLUSION: The DL method could achieve fully automated BMD calculation for opportunistic osteoporosis screening with high accuracy using ultralow-voltage 80 kV chest CT performed for lung cancer screening.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Li Y, Liu S, Zhang Y, et al. Deep Learning-enhanced Opportunistic Osteoporosis Screening in Ultralow-Voltage (80 kV) Chest CT: A Preliminary Study. Acad Radiol. 2025. PMID: 40318972. doi:10.1016/j.acra.2024.11.062

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。