多参数MRI引导经皮穿刺活检用于伴肺不张的中央型肺部病变的可行性
单中心前瞻性研究纳入107例伴阻塞后肺不张的中央型肺部可疑病变患者,采用1T开放式MRI多参数序列引导经皮同轴切割活检,诊断肺癌的敏感度97.0%、特异度100%、准确率97.2%,无严重并发症。
要点
- 多参数MRI可在89.7%患者中将中央型病变与阻塞后肺不张区分开。
- MRI引导活检诊断肺癌敏感度97.0%(98/101)、特异度100%(6/6)、准确率97.2%(104/107)。
- 无严重并发症,气胸5例均无需胸腔引流。
核心结论
- 多参数MRI引导经皮同轴切割活检不涉及电离辐射,是评估伴阻塞后肺不张的中央型肺部病变的安全、准确诊断技术。
研究设计与样本
- 单中心前瞻性研究,2015年7月至2020年12月纳入107例伴阻塞后肺不张的中央型肺部可疑病变患者,使用1T开放式MRI扫描仪行经皮同轴切割活检,采用快速T2WI-TSE序列和增强快速T1WI-TSE序列识别、定位并活检病变,DWI作为辅助序列,最终诊断由手术组织病理学或至少24个月临床随访确认。
关键影像表现/征象
- 多参数MRI在96例(89.7%)患者中可清晰区分中央型肺部病变与阻塞后肺不张。
- 使用快速T2WI-TSE序列和增强快速T1WI-TSE序列识别、定位并活检肺部病变,DWI作为辅助序列用于识别病变位置。
诊断标准与关键数值
- MRI引导经皮活检诊断肺癌的敏感度为97.0%(98/101)。
- MRI引导经皮活检诊断肺癌的特异度为100%(6/6)。
- MRI引导经皮活检诊断肺癌的准确率为97.2%(104/107)。
临床应用与阅片要点
- 对于伴阻塞后肺不张的中央型肺部病变,可考虑采用多参数MRI引导经皮同轴切割活检进行诊断评估。
- 操作中联合快速T2WI-TSE和增强快速T1WI-TSE序列识别并定位病变,DWI可作为辅助序列帮助识别病变位置。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To prospectively evaluate the feasibility, accuracy, and safety of multiparameter MRI-guided percutaneous biopsy using a 1T open MRI scanner for evaluating suspicious centrally located lung lesions with associated post-obstructive atelectasis.
MATERIALS AND METHODS: In this single-center study, MRI-guided percutaneous coaxial cutting biopsy was performed for 107 suspicious central lung lesions with associated post-obstructive atelectasis in 107 patients between July 2015 and December 2020. A fast T2-weighted imaging (T2WI)-turbo spin echo (TSE) sequence and an enhanced fast T1-weighted imaging (T1WI)-TSE sequence were used to identify, localize, and biopsy lung lesions, and diffusion-weighted imaging (DWI) was used as a supplementary sequence for identifying the lesion location. The final diagnosis was confirmed by surgical histopathology or clinical follow-up for a minimum of 24 months. The sensitivity, specificity, and accuracy for diagnosing lung malignancies were calculated, and the complications were recorded for each case.
RESULTS: Using multiparameter MRI, central lung lesions could be clearly distinguished from post-obstructive atelectasis in 96 patients (89.7%). The sensitivity, specificity, and accuracy of MRI-guided percutaneous biopsy for diagnosing lung malignancy was 97.0% (98/101), 100% (6/6), and 97.2% (104/107), respectively. Self-limited hemoptysis occurred in three patients. Pneumothorax occurred in five patients, of which none required pleural drainage. No serious procedure-related complications were observed.
CONCLUSION: As a technology that does not involve ionizing radiation, multiparameter MRI-guided percutaneous coaxial cutting biopsy is a safe and accurate diagnostic technique for evaluating centrally located lung lesions associated with post-obstructive atelectasis.
引用
- Li P, Li C, Xu Y, et al. Feasibility of Multiparameter MRI-Guided Percutaneous Biopsy for Central Lung Lesions With Atelectasis. Korean J Radiol. 2025. PMID: 40307203. doi:10.3348/kjr.2024.0818
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。