文献速递胸部MRCT

氧气增强ZTE-MRI用于肺结节评估:与CT的对比研究

Oxygen-Enhanced ZTE-MRI for Pulmonary Nodule Assessment: A Comparative Study with CT.
PubMed 文献 · Acad Radiol · 2025-05-09

本研究纳入68例受试者(80个结节),评估不同氧浓度(21%与100%)下氧气增强ZTE-MRI对肺结节的主观与客观评估价值。结果显示氧气增强ZTE-MRI的SNR显著高于ZTE-MRI,结节检出率87.5%,结节直径测量与CT高度一致(ICC 0.997),结节特征与Lung-RADS分类与CT一致性高(kappa分别为0.789与0.756)。

要点

  • 氧气增强ZTE-MRI结节检出率87.5%,结节直径测量与CT高度一致(ICC 0.997;r=0.994)。
  • 氧气增强ZTE-MRI与CT的结节特征一致性kappa=0.789,Lung-RADS分类一致性kappa=0.756。
  • 氧气增强ZTE-MRI的SNR显著高于ZTE-MRI(p<0.05),定性评分亦更优。

核心结论

  • 氧气增强ZTE-MRI在主观和客观评估上均优于常规ZTE-MRI,结节大小测量达到与CT相当的诊断性能,按Lung-RADS分类其诊断准确性逐渐接近CT。

研究设计与样本

  • 共纳入68例接受CT、ZTE-MRI或氧气增强ZTE-MRI的受试者,由两名放射科医师独立进行结节检出与Lung-RADS分类,采用SNR与CNR评估图像质量,统计方法包括Wilcoxon符号秩检验、百分比一致性、kappa值、ICC、Spearman相关与Bland-Altman分析,显著性水平p<0.05。

关键影像表现/征象

  • 氧气增强ZTE-MRI的SNR显著高于ZTE-MRI(p<0.05),定性评分亦优于ZTE-MRI。
  • 两名观察者间在氧气增强ZTE-MRI结节大小测量上具有强一致性。

诊断标准与关键数值

  • 氧气增强ZTE-MRI结节检出率为87.5%。
  • 氧气增强ZTE-MRI与CT评估结节直径的ICC为0.997、r为0.994。
  • 氧气增强ZTE-MRI与CT在结节特征上的一致性kappa=0.789,在Lung-RADS分类上的一致性kappa=0.756。

临床应用与阅片要点

  • 氧气增强ZTE-MRI在结节大小测量上与CT高度一致,可用于肺结节监测时的尺寸对比。
  • 氧气增强ZTE-MRI与CT的Lung-RADS分类一致性kappa=0.756,阅片时可参照Lung-RADS进行分类。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Frequent computed tomography (CT) scans for pulmonary nodule monitoring (every 3, 6, and 12 months) lead to increased radiation exposure and a potential risk of malignancy. Although lung magnetic resonance imaging (MRI) is gradually approaching CT in terms of performance, the effectiveness of zero-echo-time (ZTE) sequences remains to be fully optimized, particularly in terms of diagnostic accuracy under the Lung-RADS.

OBJECTIVE: This study aimed to evaluate the feasibility of oxygen-enhanced (OE) ZTE-MRI at varying oxygen concentrations (21% and 100%) for both the subjective and objective assessment of pulmonary nodules. It further explored the potential of OE-ZTE-MRI in detecting nodules, its diagnostic utility in Lung-RADS classification, and its role in evaluating malignant potential.

METHODS: A total of 68 participants who underwent CT, ZTE-MRI, or OE-ZTE-MRI, were enrolled in this study. Quantitative MRI parameters (signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]) were used to evaluate image quality. Lung nodule detection and Lung-RADS classification were performed by two radiologists independently using observer-based scoring of structural features: nodule type (solid nodule [SN], part-solid nodule [PSN], and ground-glass nodule [GGN]), and nodule size (measured manually on CT, ZTE-MRI, and OE-ZTE-MRI). Statistical analyses included the Wilcoxon signed-rank test, percentage consistency, kappa values, intraclass correlation coefficient (ICC), Spearman`s correlation, and Bland-Altman analysis. Statistical significance was set at p < 0.05.

RESULTS: Among the 68 patients (80 nodules; 57.2 ± 10.7 years; 27 males), OE-ZTE-MRI demonstrated a significantly higher SNR (p < 0.05) and superior qualitative scoring compared to ZTE-MRI. The nodule detection rate for OE-ZTE-MRI was 87.5%, with a diagnostic performance comparable to that of CT for assessing nodule diameter (ICC: 0.997; r = 0.994). OE-ZTE-MRI showed a high agreement with CT in nodule characterization (kappa = 0.789) and Lung-RADS (kappa = 0.756). Additionally, OE-ZTE-MRI exhibited strong inter-observer consistency in nodule size measurements.

CONCLUSION: OE-ZTE-MRI, which incorporates oxygen concentration adjustments, outperformed conventional ZTE-MRI in both subjective and objective evaluations. It achieves diagnostic performance comparable to that of CT in terms of nodule size. According to the Lung-RADS classification, OE-ZTE-MRI is gradually approaching the same diagnostic accuracy as CT.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Yan TC, Yu SW, Liu L, et al. Oxygen-Enhanced ZTE-MRI for Pulmonary Nodule Assessment: A Comparative Study with CT. Acad Radiol. 2025. PMID: 40348712. doi:10.1016/j.acra.2025.04.036

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。