文献速递头颈MR

深度学习CAIPIRINHA-VIBE改善并加速头颈部MRI

Deep Learning CAIPIRINHA-VIBE Improves and Accelerates Head and Neck MRI.
PubMed 文献 · Acad Radiol · 2025-05-30

这项前瞻性单中心研究纳入68例患者,在3T扫描仪上比较四种对比增强脂肪饱和VIBE序列的头颈部MRI图像质量。DL4-VIBE在整体图像质量、肌肉轮廓勾画、黏膜与咽部肌肉区分、血管显示及运动伪影方面表现更优,脂肪抑制均匀性极佳,SNR和CNR优于其他序列,且扫描时间仅0:24分钟。DL6-VIBE虽逊于DL4-VIBE,但脂肪抑制均匀性、咽黏膜勾画和CNR仍优于Star-VIBE和VIBE。

要点

  • DL4-VIBE在头颈部增强MRI中整体图像质量、肌肉轮廓和黏膜区分优于其他序列,扫描时间仅0:24分钟。
  • DL4-VIBE的SNR和CNR优于所有其他序列(p<0.001),脂肪抑制均匀性极佳(p<0.001)。
  • 金属伪影在标准VIBE中最轻,其次为DL4-VIBE(p<0.001)。

核心结论

  • DL4-VIBE以常规序列一小部分的扫描时间显著改善对比增强头颈部MRI的图像质量。

研究设计与样本

  • 前瞻性单中心研究,纳入68例转诊行颈部MRI的患者,在3T扫描仪上每人采集四种对比增强脂肪饱和VIBE序列:Star-VIBE(4:01分钟)、VIBE(2:05分钟)、DL4-VIBE(0:24分钟)、DL6-VIBE(0:17分钟)。

关键影像表现/征象

  • DL4-VIBE在整体图像质量、肌肉轮廓勾画、黏膜与咽部肌肉区分、血管显示及运动伪影方面表现更优。
  • DL4-VIBE表现出极佳的脂肪抑制均匀性(p<0.001)。
  • 金属伪影在标准VIBE中最轻,其次为DL4-VIBE(p<0.001)。
  • DL6-VIBE逊于DL4-VIBE,但脂肪抑制均匀性、咽黏膜勾画和CNR优于Star-VIBE和VIBE。

诊断标准与关键数值

  • 图像质量由三名放射科医生采用5分Likert量表评估,包括整体图像质量、肌肉轮廓勾画、黏膜与咽部肌肉显示、脂肪抑制均匀性和运动伪影。
  • 客观图像质量通过SNR、CNR和金属伪影量化评估。
  • DL4-VIBE的SNR和CNR优于所有其他序列(p<0.001)。

临床应用与阅片要点

  • DL4-VIBE可在0:24分钟内完成对比增强脂肪饱和VIBE采集,图像质量优于Star-VIBE(4:01分钟)和VIBE(2:05分钟)。
  • DL6-VIBE扫描时间0:17分钟,图像质量逊于DL4-VIBE但优于Star-VIBE和VIBE。
  • 评估金属伪影时,标准VIBE伪影最轻,DL4-VIBE次之。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: The aim of this study was to evaluate image quality for contrast-enhanced (CE) neck MRI with a deep learning-reconstructed VIBE sequence with acceleration factors (AF) 4 (DL4-VIBE) and 6 (DL6-VIBE).

METHODS: Patients referred for neck MRI were examined in a 3-Tesla scanner in this prospective, single-center study. Four CE fat-saturated (FS) VIBE sequences were acquired in each patient: Star-VIBE (4:01 min), VIBE (2:05 min), DL4-VIBE (0:24 min), DL6-VIBE (0:17 min). Image quality was evaluated by three radiologists with a 5-point Likert scale and included overall image quality, muscle contour delineation, conspicuity of mucosa and pharyngeal musculature, FS uniformity, and motion artifacts. Objective image quality was assessed with signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and quantification of metal artifacts.

RESULTS: 68 patients (60.3% male; mean age 57.4±16 years) were included in this study. DL4-VIBE was superior for overall image quality, delineation of muscle contours, differentiation of mucosa and pharyngeal musculature, vascular delineation, and motion artifacts. Notably, DL4-VIBE exhibited exceptional FS uniformity (p<0.001). SNR and CNR were superior for DL4-VIBE compared to all other sequences (p<0.001). Metal artifacts were least pronounced in the standard VIBE, followed by DL4-VIBE (p<0.001). Although DL6-VIBE was inferior to DL4-VIBE, it demonstrated improved FS homogeneity, delineation of pharyngeal mucosa, and CNR compared to Star-VIBE and VIBE.

CONCLUSION: DL4-VIBE significantly improves image quality for CE neck MRI with a fraction of the scan time of conventional sequences.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Nitschke LV, Lerchbaumer M, Ulas T, et al. Deep Learning CAIPIRINHA-VIBE Improves and Accelerates Head and Neck MRI. Acad Radiol. 2025. PMID: 40447509. doi:10.1016/j.acra.2025.05.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。