基于MRI的深度学习模型预测胶质瘤1p/19q共缺失状态:诊断试验准确性研究的系统评价与Meta分析
该系统评价与Meta分析纳入20项研究,其中10项进入Meta分析,评估基于MRI的端到端深度学习模型预测胶质瘤1p/19q共缺失状态的效能,合并敏感度0.77、特异度0.85、AUC 0.89;亚组分析发现不同分割方法组间差异显著,作者认为该模型可高精度预测共缺失状态并可能辅助无创肿瘤表征及治疗策略选择。
要点
- 深度学习模型预测胶质瘤1p/19q共缺失的合并敏感度0.77、特异度0.85、AUC 0.89。
- 合并阳性似然比5.34、阴性似然比0.26、诊断比值比20.24。
- 亚组分析显示不同分割方法组间存在显著差异,为异质性来源之一。
核心结论
- 深度学习模型能以较高准确性预测胶质瘤1p/19q共缺失状态,可能增强无创肿瘤表征并有助于选择最佳治疗策略。
研究设计与样本
- 系统评价与Meta分析,检索PubMed、Web of Science、Embase和Scopus四个数据库,纳入20项评估端到端深度学习模型预测胶质瘤1p/19q共缺失状态的研究。
诊断标准与关键数值
- 10项研究Meta分析:合并敏感度0.77(95%CI 0.63-0.87),特异度0.85(95%CI 0.74-0.92)。
- 合并阳性诊断似然比5.34(95%CI 2.88-9.89),阴性诊断似然比0.26(95%CI 0.16-0.45)。
- 合并诊断比值比20.24(95%CI 8.19-50.02),AUC 0.89(95%CI 0.86-0.91)。
- 亚组分析发现不同分割方法组间存在显著差异。
局限性
- 20项纳入研究中仅2项质量为低质量。
- 亚组分析发现不同分割方法组间存在显著差异,提示分割方法是异质性来源之一。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: We conducted a systematic review and meta-analysis to evaluate the performance of magnetic resonance imaging (MRI)-derived deep learning (DL) models in predicting 1p/19q codeletion status in glioma patients.
METHODS: The literature search was performed in four databases: PubMed, Web of Science, Embase, and Scopus. We included the studies that evaluated the performance of end-to-end DL models in predicting the status of glioma 1p/19q codeletion. The quality of the included studies was assessed by the Quality assessment of diagnostic accuracy studies-2 (QUADAS-2) METhodological RadiomICs Score (METRICS). We calculated diagnostic pooled estimates and heterogeneity was evaluated using I2. Subgroup analysis and sensitivity analysis were conducted to explore sources of heterogeneity. Publication bias was evaluated by Deeks' funnel plots.
RESULTS: Twenty studies were included in the systematic review. Only two studies had a low quality. A meta-analysis of the ten studies demonstrated a pooled sensitivity of 0.77 (95% CI: 0.63-0.87), a specificity of 0.85 (95% CI: 0.74-0.92), a positive diagnostic likelihood ratio (DLR) of 5.34 (95% CI: 2.88-9.89), a negative DLR of 0.26 (95% CI: 0.16-0.45), a diagnostic odds ratio of 20.24 (95% CI: 8.19-50.02), and an area under the curve of 0.89 (95% CI: 0.86-0.91). The subgroup analysis identified a significant difference between groups depending on the segmentation method used.
CONCLUSION: DL models can predict glioma 1p/19q codeletion status with high accuracy and may enhance non-invasive tumor characterization and aid in the selection of optimal therapeutic strategies.
引用
- Ahmadzadeh AM, Broomand Lomer N, Ashoobi MA, et al. MRI-derived deep learning models for predicting 1p/19q codeletion status in glioma patients: a systematic review and meta-analysis of diagnostic test accuracy studies. Neuroradiology. 2025. PMID: 40369298. doi:10.1007/s00234-025-03631-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。