低kV低对比剂多期CT肺动脉造影非刚性时间配准的可行性研究:双源CT
前瞻性随机纳入疑似急性肺栓塞患者72例,分别行多期或单期CTPA,多期组对比剂15 mL、单期组40 mL,多期组后处理行非刚性时间配准。两组辐射剂量与大部分客观图像质量相似,多期组主观图像质量优于单期组,诊断信心两位阅片者评价不一。
要点
- 多期CTPA使用15 mL对比剂,单期CTPA使用40 mL,多期方案显著减少对比剂用量。
- 两位阅片者均评价多期CTPA主观图像质量在统计学上优于单期CTPA。
- 两组辐射剂量及除右主肺动脉外CNR相似,诊断信心一位阅片者评价相似、另一位略有差异。
核心结论
- 多期CTPA非刚性时间配准可提供与单期方案相似甚至更好的图像质量,并显著减少对比剂用量。
研究设计与样本
- 前瞻性随机研究,连续纳入疑似急性肺栓塞患者72例(多期CTPA组37例、单期CTPA组35例),采用双源CT,多期CTPA后处理行非刚性时间配准。
关键影像表现/征象
- 多期CTPA组确诊肺栓塞5例,单期CTPA组确诊7例。
- 两组患者人口学特征相似,但单期CTPA组年龄较大。
- 两组辐射剂量及右主肺动脉外CNR相似,右主肺动脉CNR存在差异。
- 两位阅片者均评价多期CTPA主观图像质量在统计学上优于单期CTPA。
- 诊断信心一位阅片者评价两组相似,另一位阅片者评价略有差异。
诊断标准与关键数值
- 多期CTPA对比剂用量15 mL,单期CTPA对比剂用量40 mL。
- 图像质量评估包括客观测量、主观印象及诊断信心,由两位经验丰富放射科医师独立评价。
临床应用与阅片要点
- 多期CTPA结合非刚性时间配准可在降低对比剂用量至15 mL的同时获得不劣于甚至优于单期40 mL方案的图像质量。
- 日常阅片需注意两组辐射剂量相似,右主肺动脉CNR存在组间差异。
- 诊断信心评价在两位阅片者间不完全一致,提示主观评价可能存在阅片者间差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: This study aimed to compare the nonrigid temporal registration of multiphase computed tomography pulmonary angiography (CTPA) with single-phase CTPA in terms of radiation dose, contrast agent usage, objective and subjective image quality.
MATERIALS AND METHODS: Consecutive patients suspected of acute pulmonary embolism were prospectively included in this study, and randomly received multiphase or single-phase CTPA. Regarding the contrast media, 15 mL was applied in the multiphase CTPA in comparison with 40 mL applied in the single-phase CTPA. Temporal registration was performed for multiphase CTPA during post-processing. Two experienced radiologists independently evaluated the image quality (IQ) based on objective measurements, subjective impression and diagnostic confidence. Patient demographics, scan parameters and image quality were compared between the two groups.
RESULTS: A total of 72 patients were analysed (37 multiphase CTPA and 35 single-phase CTPA). Positive pulmonary embolism was confirmed in five and seven patients, respectively. The two patient groups had similar demographics besides older age in those who underwent single-phase CTPA. Radiation dose and the contrast-to-noise ratio (CNR) were also similar between groups except for the CNR in the right main pulmonary artery. Both readers rated the multiphase CTPA with a statistically superior subjective IQ over the single-phase CTPA. The diagnostics confidence of the two CTPA protocols was similarly rated by one reader and slightly different according to the second reader.
CONCLUSION: The nonrigid temporal registration of multiphase CT pulmonary angiography could offer similar or even better image quality than the single-phase protocol and significantly reduce the amount of contrast usage.
引用
- Zhang QH, Lin SS, Zhao X, et al. Nonrigid temporal registration of multiphase CT pulmonary angiography using low-kV and low contrast: a feasibility study with dual-source CT. Clin Radiol. 2025. PMID: 40279855. doi:10.1016/j.crad.2025.106916