文献速递腹部泌尿生殖US

基于三维直肠腔内超声的深度学习计算机辅助诊断工具用于直肠癌术前T分期

Computer-aided diagnosis tool utilizing a deep learning model for preoperative T-staging of rectal cancer based on three-dimensional endorectal ultrasound.
PubMed 文献 · Abdom Radiol (NY) · 2025-04-30

回顾性分析216例直肠癌患者的3D-ERUS数据,随机分为训练组156例和测试组60例,开发深度学习CAD工具用于术前T分期。CAD工具对各T分期均有较高诊断效能,T1期最佳(AUC 0.85)。CAD辅助可提高放射科医师(尤其低年资医师)的AUC及诊断一致性。

要点

  • CAD工具对直肠癌各T分期诊断效能较高,T1期AUC达0.85。
  • CAD辅助使低年资医师1的T2期AUC从0.61升至0.79(P=0.013)。
  • CAD辅助使低年资医师诊断一致性κ值从0.31升至0.64(P=0.005)。

核心结论

  • 基于3D-ERUS图像的深度学习CAD工具在直肠癌T分期中表现良好,可提高放射科医师的术前评估性能和诊断一致性。

研究设计与样本

  • 回顾性分析216例直肠癌患者3D-ERUS数据,随机分为训练组156例和测试组60例,由放射科医师在有无CAD辅助下解读测试组图像。

诊断标准与关键数值

  • CAD工具对T1期肿瘤诊断效能最佳:AUC 0.85(95%CI 0.73-0.93)。
  • 低年资医师2辅助后T1期AUC从0.76(95%CI 0.63-0.86)升至0.80(95%CI 0.68-0.94)(P=0.020)。
  • 低年资医师1辅助后T2期AUC从0.61(95%CI 0.48-0.73)升至0.79(95%CI 0.66-0.88)(P=0.013)。
  • 低年资医师1辅助后T3期AUC从0.73(95%CI 0.60-0.84)升至0.84(95%CI 0.72-0.92)(P=0.038)。
  • 诊断一致性κ值:低年资医师从0.31升至0.64(P=0.005),高年资医师从0.52升至0.66(P=0.005)。

临床应用与阅片要点

  • CAD工具可辅助低年资放射科医师提高直肠癌T分期诊断准确性及一致性。
  • 辅助后T1期AUC由0.76升至0.80(低年资医师2),T2期由0.61升至0.79(低年资医师1),T3期由0.73升至0.84(低年资医师1)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: The prognosis and treatment outcomes for patients with rectal cancer are critically dependent on an accurate and comprehensive preoperative evaluation.Three-dimensional endorectal ultrasound (3D-ERUS) has demonstrated high accuracy in the T staging of rectal cancer. Thus, we aimed to develop a computer-aided diagnosis (CAD) tool using a deep learning model for the preoperative T-staging of rectal cancer with 3D-ERUS.

METHODS: We retrospectively analyzed the data of 216 rectal cancer patients who underwent 3D-ERUS. The patients were randomly assigned to a training cohort (n = 156) or a testing cohort (n = 60). Radiologists interpreted the 3D-ERUS images of the testing cohort with and without the CAD tool. The diagnostic performance of the CAD tool and its impact on the radiologists' interpretations were evaluated.

RESULTS: The CAD tool demonstrated high diagnostic efficacy for rectal cancer tumors of all T stages, with the best diagnostic performance achieved for T1-stage tumors (AUC, 0.85; 95% CI, 0.73-0.93). With assistance from the CAD tool, the AUC for T1 tumors improved from 0.76 (95% CI, 0.63-0.86) to 0.80 (95% CI, 0.68-0.94) (P = 0.020) for junior radiologist 2. For junior radiologist 1, the AUC improved from 0.61 (95% CI, 0.48-0.73) to 0.79 (95% CI, 0.66-0.88) (P = 0.013) for T2 tumors and from 0.73 (95% CI, 0.60-0.84) to 0.84 (95% CI, 0.72-0.92) (P = 0.038) for T3 tumors. The diagnostic consistency (κ value) also improved from 0.31 to 0.64 (P = 0.005) for the junior radiologists and from 0.52 to 0.66 (P = 0.005) for the senior radiologists.

CONCLUSION: A CAD tool utilizing a deep learning model based on 3D-ERUS images showed strong performance in T staging rectal cancer. This tool could improve the performance of and consistency between radiologists in preoperatively assessing rectal cancer patients.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Liu X, Zhang R, Chen J, et al. Computer-aided diagnosis tool utilizing a deep learning model for preoperative T-staging of rectal cancer based on three-dimensional endorectal ultrasound. Abdom Radiol (NY). 2025. PMID: 40304753. doi:10.1007/s00261-025-04966-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。