文献速递头颈技术与安全CT

牙种植体伪影:光子计数CT衍生虚拟单能图像联合迭代金属伪影去除算法的评估

Dental implant artifacts: Evaluation of photon counting CT-derived virtual monoenergetic images in combination with iterative metal artifact reduction algorithms.
PubMed 文献 · Eur J Radiol · 2025-04-14

回顾性纳入49例牙种植体患者,比较常规CT图像与不同能级虚拟单能图像(70–190 keV)单独或联合迭代金属伪影去除算法(iMAR)的伪影减少效果。iMAR单独应用及联合虚拟单能图像均显著减少低密度和高密度伪影并改善邻近组织可评估性,而虚拟单能图像单独应用伪影减少不充分。联合方案在高于100 keV能级效果最佳。

要点

  • iMAR单独或联合虚拟单能图像均可显著减少牙种植体低密度和高密度伪影。
  • 虚拟单能图像单独应用伪影减少不充分,需联合iMAR。
  • 联合方案在高于100 keV能级对邻近软组织和骨的可评估性最佳。

核心结论

  • iMAR单独应用及iMAR联合虚拟单能图像均显著减少牙种植体伪影并改善邻近组织可评估性,联合方案在高于100 keV能级效果最佳。

研究设计与样本

  • 回顾性纳入49例牙种植体患者,比较常规多能CT图像与不同能级(70–190 keV)虚拟单能图像单独及联合iMAR的伪影减少效果,采用ROI定量测量和两名放射科医师Likert量表定性评估。

关键影像表现/征象

  • iMAR单独应用及联合虚拟单能图像有效减少低密度和高密度伪影,虚拟单能图像单独应用伪影减少不充分。
  • 定量伪影减少最佳能级:低密度伪影为虚拟单能图像联合iMAR 100 keV,高密度伪影为70 keV,骨和血管为190 keV。
  • 定性评估中虚拟单能图像联合iMAR的伪影减少程度评分显著高于常规CT图像,190 keV对受伪影影响的软组织和骨评估评分最佳,虚拟单能图像单独应用未显示显著改善。

临床应用与阅片要点

  • 临床可联合使用iMAR与光子计数CT衍生虚拟单能图像以减少牙种植体伪影、改善颌面部邻近组织可评估性,联合方案在高于100 keV能级效果最佳。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To examine photon counting-CT (PCCT)-derived virtual monoenergetic images (VMI) in combination with iterative metal artifacts reduction algorithms (iMAR) for artifact reduction in patients with dental implants (DI).

METHODS: 49 patients with DI were retrospectively included in the study. Polyenergetic CT images (CI), VMIs with different energy levels (70-190 keV) without and the same images with iMAR were examined. ROI-based measurements of hypo- and hyperdense artifacts in different tissues (soft tissues, bones, vessels) were performed. Qualitative assessment of the extent of artifacts, surrounding bone and soft tissue was performed by two radiologists using a Likert scale.

RESULTS: iMAR effectively reduced hypo- and hyperdense artifacts by solitary application and in combination with VMI. In contrast, solitary application of VMI did not yield sufficient artifact reduction. Optimal quantitative reduction was achieved in VMIiMAR 100 keV for hypodense artifacts and 70 keV for hyperdense artifacts. VMIiMAR 190 keV provided optimal artifact reduction in bones and vessels. In the qualitative evaluation, the extent of artifact reduction received significantly higher ratings on VMIiMAR than CI. VMIiMAR 190 keV was rated best for evaluation of artifact-affected soft tissue and bone, VMI did not yield significant improvements.

CONCLUSIONS: iMAR as a standalone approach and the combination of iMAR and VMI significantly reduce artifacts by DI and improve the assessability of adjacent tissue. Combination of iMAR and VMI worked best at keV levels higher than 100 keV.

CLINICAL RELEVANCE STATEMENT: Combination of iMAR and PCCT-derived VMI is a useful approach for enhancing the diagnostic assessability of the maxillofacial area in patients with dental implants.