直肠深度学习重建DWI:PROPELLER、减小视野与常规DWI的比较
这项前瞻性研究纳入38例直肠肿瘤患者的42次MRI检查,比较PROPELLER-DWI、rFOV-DWI与cDWI联合深度学习重建的图像质量和诊断性能。PROPELLER-DWI伪影和变形最少但感知噪声最差,rFOV-DWI锐利度最佳;PROPELLER-DWI和rFOV-DWI整体图像质量及直肠/肿瘤清晰度显著优于cDWI,图像质量欠佳发生率显著低于cDWI;三种DWI分期和再分期准确率无显著差异,PROPELLER-DWI的读者间一致性最高。
要点
- PROPELLER-DWI和rFOV-DWI联合深度学习重建可减少伪影/变形或提高锐利度,图像质量优于cDWI。
- PROPELLER-DWI图像质量欠佳发生率最低,读者间一致性最高(加权kappa 0.62-0.71)。
- 三种DWI对直肠肿瘤分期和再分期准确率无显著差异。
核心结论
- PROPELLER-DWI和rFOV-DWI联合深度学习重建可能通过减少伪影和变形或提高锐利度改善直肠DWI图像质量,但对诊断准确率的影响不显著。
研究设计与样本
- 前瞻性研究,纳入38例直肠肿瘤患者的42次MRI检查,行初始分期和/或再分期MRI,由两名放射科医生比较PROPELLER-DWI、rFOV-DWI和cDWI联合深度学习重建的图像质量及诊断性能。
关键影像表现/征象
- PROPELLER-DWI的伪影和变形显著最少,但感知噪声最差。
- rFOV-DWI对两名读者的锐利度均显著最佳(P < 0.01)。
- PROPELLER-DWI和rFOV-DWI的整体图像质量及直肠/肿瘤清晰度在两名读者中均显著优于cDWI(P < 0.01)。
诊断标准与关键数值
- 图像质量欠佳发生率:PROPELLER-DWI两名读者分别为5例和1例,rFOV-DWI为14例和6例,cDWI为29例和25例,PROPELLER-DWI和rFOV-DWI显著低于cDWI(P < 0.01)。
- 分期和再分期准确率:三种DWI间无显著差异。
- 读者间一致性:PROPELLER-DWI加权kappa 0.62-0.71,rFOV-DWI加权kappa 0.47-0.61,cDWI加权kappa 0.38-0.52。
临床应用与阅片要点
- PROPELLER-DWI和rFOV-DWI联合深度学习重建可能改善直肠DWI的图像质量,但对诊断准确率的影响不显著。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare the image quality and diagnostic performance of periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER), reduced field-of-view (rFOV), and conventional diffusion-weighted imaging (cDWI) combined with deep learning reconstruction (DLR) for evaluating rectal tumors.
METHODS: This prospective study included 42 MRI examinations of 38 patients with rectal tumors who underwent initial staging and/or restaging MRI. PROPELLER-DWI, rFOV-DWI, and cDWI obtained with DLR were reviewed by two radiologists and compared for image quality and diagnostic performance for local tumor extent at staging and restaging and response to chemoradiotherapy at restaging.
RESULTS: PROPELLER-DWI had significantly the least artifacts and distortions, but the worst perceptive noise, while rFOV-DWI had significantly the best sharpness for both readers (P < 0.01). For overall image quality and rectal/tumor conspicuity, PROPELLER-DWI and rFOV-DWI were significantly superior to cDWI in both readers (P < 0.01). The incidence of suboptimal image quality was significantly lower with PROPELLER-DWI and rFOV-DWI than with cDWI (5 and 1 patients with PROPELLER-DWI, 14 and 6 with rFOV-DWI, and 29 and 25 with cDWI by the 2 readers, P < 0.01). Although there were no significant differences in the accuracy of staging and restaging among the 3 types of DWI, inter-reader agreement was highest for PROPELLER-DWI (weighted kappa, 0.62-0.71) compared with cDWI (weighted kappa, 0.38-0.52) and rFOV-DWI (weighted kappa, 0.47-0.61).
CONCLUSIONS: PROPELLER-DWI and rFOV-DWI with DLR may improve the image quality of rectal DWI by reducing artifacts and distortions or increasing sharpness, although the impact on diagnostic accuracy was not significant.
引用
- Matsumoto S, Tsuboyama T, Onishi H, et al. DWI of the rectum with deep learning reconstruction: comparison of PROPELLER, reduced FOV, and conventional DWI. Abdom Radiol (NY). 2025. PMID: 40244478. doi:10.1007/s00261-025-04950-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。