文献速递胸部技术与安全DR

PRECISE框架:利用GPT增强放射学报告的可读性、可靠性和以患者为中心的护理

PRECISE framework: Enhanced radiology reporting with GPT for improved readability, reliability, and patient-centered care.
PubMed 文献 · Eur J Radiol · 2025-04-17

本研究使用500份胸部X线报告评估PRECISE框架,该框架利用GPT-4生成六年级阅读水平的患者友好摘要。结果显示可读性评分显著改善(Flesch阅读轻松度从38.28升至80.82,P<0.001),临床志愿者认为95%的摘要可靠,非医学志愿者认为97%的摘要完全可理解。结论提示该方法有望在不增加放射科医生显著负担的情况下改善患者理解与沟通。

要点

  • PRECISE框架用GPT-4将放射学报告转为六年级阅读水平的患者友好摘要。
  • 可读性显著改善:Flesch阅读轻松度从38.28升至80.82(P<0.001)。
  • 临床志愿者认为95%的摘要可靠,非医学志愿者认为97%完全可理解。

核心结论

  • 应用PRECISE方法在改善患者理解和沟通方面显示出前景,且不增加放射科医生的显著负担。

研究设计与样本

  • 使用500份胸部X线报告评估PRECISE框架;可读性用Flesch阅读轻松度、Gunning Fog指数和自动可读性指数评估,可靠性由临床志愿者评估,可理解性由非医学志愿者评估;采用t检验、回归分析和Mann-Whitney U检验进行统计分析。

诊断标准与关键数值

  • Flesch阅读轻松度均值从38.28升至80.82(P<0.001)。
  • Gunning Fog指数从13.04降至6.99(P<0.001)。
  • 自动可读性指数从13.33改善至5.86(P<0.001)。
  • 临床志愿者评估95%的摘要可靠。
  • 非医学志愿者评估97%的PRECISE生成摘要完全可理解。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: The PRECISE framework, defined as Patient-Focused Radiology Reports with Enhanced Clarity and Informative Summaries for Effective Communication, leverages GPT-4 to create patient-friendly summaries of radiology reports at a sixth-grade reading level.

PURPOSE: The purpose of the study was to evaluate the effectiveness of the PRECISE framework in improving the readability, reliability, and understandability of radiology reports. We hypothesized that the PRECISE framework improves the readability and patient understanding of radiology reports compared to the original versions.

MATERIALS AND METHODS: The PRECISE framework was assessed using 500 chest X-ray reports. Readability was evaluated using the Flesch Reading Ease, Gunning Fog Index, and Automated Readability Index. Reliability was gauged by clinical volunteers, while understandability was assessed by non-medical volunteers. Statistical analyses including t-tests, regression analyses, and Mann-Whitney U tests were conducted to determine the significance of the differences in readability scores between the original and PRECISE-generated reports.

RESULTS: Readability scores significantly improved, with the mean Flesch Reading Ease score increasing from 38.28 to 80.82 (p-value < 0.001), the Gunning Fog Index decreasing from 13.04 to 6.99 (p-value < 0.001), and the ARI score improving from 13.33 to 5.86 (p-value < 0.001). Clinical volunteer assessments found 95 % of the summaries reliable, and non-medical volunteers rated 97 % of the PRECISE-generated summaries as fully understandable.

CONCLUSION: The application of the PRECISE approach demonstrates promise in enhancing patient understanding and communication without adding significant burden to radiologists. With improved reliability and patient-friendly summaries, this approach holds promise for fostering patient engagement and understanding in healthcare decision-making. The PRECISE framework represents a pivotal step towards more inclusive and patient-centric care delivery.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Tripathi S, Mutter L, Muppuri M, et al. PRECISE framework: Enhanced radiology reporting with GPT for improved readability, reliability, and patient-centered care. Eur J Radiol. 2025. PMID: 40286532. doi:10.1016/j.ejrad.2025.112124

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。