利用暗脂处理改善两点Dixon MRI的组织对比可视化:在临床膝关节成像中的应用

Improving tissue contrast visualization in two-point Dixon MRI using dark-fat processing: application in clinical knee imaging.
PubMed 文献 · Skeletal Radiol · 2025-04-12

回顾性纳入36例临床膝关节MRI,比较暗脂处理水脂分离图像与常规水脂分离图像。20例定性定量分析显示暗脂图像脂肪抑制更好、坐骨神经显示更佳、半月板与关节软骨对比噪声比提高;16例评估交叉韧带撕裂,MRI识别后交叉韧带撕裂数多于关节镜。

要点

  • 暗脂处理水脂分离图像脂肪抑制优于常规水脂分离图像,阅片者1 P<0.0001、阅片者2 P<0.05。
  • 暗脂图像骨髓脂肪表观信噪比显著降低(P<0.0001),半月板与关节软骨表观对比噪声比显著提高(P<0.0001)。
  • 暗脂图像整体图像质量(阅片者1 P<0.001)和坐骨神经显示(阅片者1 P<0.01)改善,其余解剖结构无显著差异。

核心结论

  • 暗脂处理水脂分离图像较两点TSE-Dixon常规水脂分离图像改善了脂肪抑制和组织对比可视化,尤其对坐骨神经显示更佳。

研究设计与样本

  • 回顾性研究,经IRB批准回顾性收集36例临床膝关节MRI数据集,比较暗脂水脂分离图像与两点TSE-Dixon常规水脂分离图像。

关键影像表现/征象

  • 暗脂水脂分离图像脂肪抑制较常规水脂分离图像改善(阅片者1 P<0.0001;阅片者2 P<0.05)。
  • 暗脂水脂分离图像整体图像质量较常规水脂分离图像改善(阅片者1 P<0.001)。
  • 暗脂水脂分离图像坐骨神经显示较常规水脂分离图像改善(阅片者1 P<0.01),其余解剖结构无显著差异。
  • 暗脂水脂分离图像骨髓脂肪表观信噪比显著降低(P<0.0001)。
  • 暗脂水脂分离图像半月板与关节软骨之间表观对比噪声比显著提高(P<0.0001)。

诊断标准与关键数值

  • 20例患者水脂分离图像由两名经验丰富的肌骨放射科医师定性评估整体图像质量、脂肪抑制、解剖可视化和伪影缺失,采用Wilcoxon秩和检验。
  • 20例患者水脂分离图像基于感兴趣区计算表观信噪比和表观对比噪声比,采用配对t检验。
  • 16例患者统计MRI识别的交叉韧带撕裂数量并与关节镜结果比较,MRI识别的后交叉韧带撕裂数多于关节镜。

临床应用与阅片要点

  • 暗脂处理可在两点TSE-Dixon水脂分离图像上改善脂肪抑制和半月板与关节软骨对比,阅片时可关注该处理对骨髓脂肪信号的抑制效果。
  • 暗脂处理对坐骨神经显示有改善,但其余解剖结构显示无显著差异。
  • MRI识别的后交叉韧带撕裂数多于关节镜,解读交叉韧带撕裂时需结合关节镜结果。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To improve tissue contrast visualization in water-only images from two-point turbo spin-echo (TSE) Dixon MRI using dark-fat image processing and evaluate in retrospectively acquired clinical knee images.

MATERIALS AND METHODS: Clinical knee MRI datasets from 36 patients were retrospectively compiled under IRB approval. The dark-fat water-only images were generated and compared with the conventional water-only images from two-point TSE-Dixon MRI. The water-only images from 20 patients were analyzed: (i) qualitatively by two experienced musculoskeletal radiologists, for overall image quality, fat suppression, anatomical visualization, and the absence of artifacts, using Wilcoxon rank tests, and (ii) quantitatively using apparent signal-to-noise ratio (aSNR) and apparent contrast-to-noise ratio (aCNR) from regions of interest (ROIs) with paired t-test. In the remaining 16 patients, the number of cruciate ligament tears identified on MRI was tabulated and compared with arthroscopy results.

RESULTS: Compared to conventional water-only images, dark-fat water-only images showed improved fat suppression (reader 1, P < 0.0001; reader 2, P < 0.05), improved overall image quality by reader 1 (P < 0.001), and improved visualization of the sciatic nerve for reader 1 (P < 0.01), while there were no significant differences for the other anatomical structures. aSNR was significantly reduced for bone marrow fat (P < 0.0001), and aCNR between meniscus and articular cartilage was significantly improved (P < 0.0001). There were a higher number of posterior cruciate ligament tears identified in MRI compared to arthroscopy.

CONCLUSION: Dark-fat processed water-only images improved fat suppression and tissue contrast visualization, particularly sciatic nerves, compared to conventional water-only images from two-point TSE-Dixon MR imaging.

来源:Skeletal Radiol,查看原文。版权归原作者所有。