乳腺表观扩散系数分类系统联合乳腺影像报告和数据系统评估可提高乳腺病变诊断特异度
单机构回顾性研究纳入358例女性376个乳腺病变(236恶性、140良性),评估预设乳腺表观扩散系数(ADC-B)分类系统鉴别良恶性的诊断效能并与BI-RADS比较。ADC-B分类系统AUC为0.858,高于BI-RADS的0.805(P=0.029);两者联合后特异度从17.1%升至49.5%(ADC可测病变)及从20%升至45.6%(全部病变,P<0.001),敏感度保持不变。
要点
- ADC-B分类系统诊断效能AUC 0.858,高于BI-RADS的AUC 0.805(P=0.029)。
- ADC-B联合BI-RADS后特异度从17.1%升至49.5%(ADC可测病变),敏感度保持不变。
- ADC测量与ADC-B分类的读者间一致性极佳(ICC分别为0.991和0.967)。
核心结论
- 预设ADC-B分类系统联合BI-RADS有潜力以高准确度对乳腺病变类型进行分类,在保持敏感度的同时显著提高BI-RADS特异度。
研究设计与样本
- 单机构回顾性研究,纳入2019年4月至2023年5月行乳腺MRI的患者,共376个病变(358例女性,平均年龄46.29岁,SD 11.03),采用3-T MRI系统行动态对比增强MRI和扩散加权成像,以组织学为参考标准。
诊断标准与关键数值
- ADC-B分类系统总体AUC 0.858(95%CI 0.816-0.894),BI-RADS AUC 0.805(95%CI 0.759-0.846),两者比较P=0.029;ADC-B联合BI-RADS的AUC在ADC可测病变为0.870(95%CI 0.829-0.904),在全部病变为0.861(95%CI 0.822-0.894)。
临床应用与阅片要点
- 作者指出,尽管DWI已纳入许多医学中心的临床MRI方案,但尚未纳入官方BI-RADS标准;在BI-RADS分类基础上加入ADC-B分类系统可显著提高乳腺病变分类特异度而不降低敏感度。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To investigate the diagnostic performance of the predefined breast apparent diffusion coefficient (ADC-B) category system in differentiating malignant from benign breast lesions and to compare with the Breast Imaging Reporting and Data System (BI-RADS).
METHODS: This was a single-institution retrospective study of patients who underwent breast MRI between April 2019 and May 2023. Dynamic contrast-enhanced (DCE) MRI and diffusion weighted imaging (DWI) were performed using a 3-T MRI system. Data on lesion morphology (mass, non-mass), size, and ADC were collected. Histology was the standard of reference. The analysis assessed the inter-reader agreement in measuring ADC and ADC-B category using the intraclass correlation coefficient (ICC), as well as the diagnostic performance based on the receiver operating characteristic (ROC) curve.
RESULTS: A total of 376 lesions in 358 women (mean age, 46.29 years; SD, 11.03) with pathologic results (236 malignant and 140 benign) were included. The inter-reader agreement was excellent in measuring ADC (ICC = 0.991) and assessing ADC-B category (ICC = 0.967). Overall diagnostic performance for ADC-B category (area under the curve [AUC], 0.858; 95% CI: 0.816-0.894) was higher than for BI-RADS (AUC, 0.805; 95% CI: 0.759-0.846; P = 0.029). The AUC of ADC-B category combined with BI-RADS reached 0.870 (95% CI: 0.829-0.904) for ADC-measurable lesions and 0.861 (95% CI: 0.822-0.894) for all lesions. The diagnostic combination significantly improves the specificity of BI-RADS (from 17.1% to 49.5% for ADC measurable lesions and from 20% to 45.6% for all lesions; P < 0.001) while maintaining sensitivity.
CONCLUSION: The combination of predefined ADC-B category and BI-RADS has the potential to enable classification of breast lesion types with high accuracy.
ADVANCE IN KNOWLEDGE: While DWI has been incorporated into clinical MRI protocols at numerous medical centres, it has not been included in the official BI-RADS criteria. Adding ADC-B category system to BI-RADS classification significantly improves the specificity of breast lesion classification without decreasing sensitivity compared to the BI-RADS alone.
引用
- Zhang B, Guo Z, Chen X, et al. Combining a breast apparent diffusion coefficient category system with Breast Imaging Reporting and Data System assessment improves specificity of breast lesions diagnosis. Br J Radiol. 2025. PMID: 40268740. doi:10.1093/bjr/tqaf084
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。