文献速递乳腺技术与安全乳腺X线USMR

一项多中心观察性试点研究:评估使用可信赖专业活动清单对住院医师轮转中期形成性反馈的影响——以乳腺诊断影像为背景

A Multicenter Observational Pilot Study Evaluating the Effect of Using an Entrustable Professional Activity Checklist on Resident Mid-Rotation Formative Feedback in Diagnostic Breast Imaging.
PubMed 文献 · Acad Radiol · 2025-04-10

该多中心观察性试点研究采用六步方法开发了基于可信赖专业活动的乳腺诊断影像轮转中期清单,并通过实施前后问卷调查评估其对住院医师形成性反馈频率、质量和感知的影响。结果显示81%的住院医师和78%的教学主治医师认为该结构化反馈清单有助于评估住院医师表现,100%的主治医师认为其提升了给出具体、及时、可操作反馈的能力,84%的住院医师认为反馈有助于调整后续学习方向。

要点

  • 基于可信赖专业活动的轮转中期清单可提升乳腺诊断影像住院医师形成性反馈的频率和质量。
  • 81%住院医师和78%教学主治医师认为该清单有助于评估住院医师在乳腺诊断影像轮转中的表现。
  • 100%教学主治医师认为清单提升了给出具体、及时、可操作和周到反馈的能力。

核心结论

  • 使用基于可信赖专业活动的结构化轮转中期清单可改善住院医师形成性反馈的频率和质量,且住院医师和教学主治医师均持正面看法。

研究设计与样本

  • 多中心观察性试点研究,经IRB批准,采用六步方法开发经验证的基于可信赖专业活动的清单,并进行实施前后问卷调查和数据分析。

诊断标准与关键数值

  • 32名住院医师中26名(81%)和9名教学主治医师中7名(78%)认为结构化反馈清单有助于评估住院医师在乳腺诊断影像轮转中的表现。
  • 9名教学主治医师中9名(100%)表示清单提升了其给出具体、及时、可操作和周到反馈的能力,6名(67%)同意其反馈更具结构性。
  • 32名住院医师中27名(84%)认为所获反馈使其能够在轮转剩余时间内针对需改进领域调整学习。

临床应用与阅片要点

  • 作者结论认为,使用基于可信赖专业活动的结构化轮转中期清单可改善住院医师形成性反馈的频率和质量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONAL AND OBJECTIVE: Formative feedback is an important strategy to improve resident learning. The purpose of our study is to evaluate the impact on frequency, quality and perceptions of resident formative feedback after implementation of a diagnostic breast imaging specific entrustable professional activity based mid-rotation checklist.

MATERIAL AND METHODS: In this IRB-approved multicenter study, a six-step methodology was used to develop the validated EPA based checklist, participant pre- and post-implementation surveys, and analyze the collected data.

RESULTS: 26 out of 32 (81%) residents and 7 out of 9 (78%) teaching attendings found the structured feedback checklist helpful in evaluating residents' performance on the diagnostic breast imaging rotation. 9 of 9 (100%) attending stated it improved their ability to give specific, timely, actionable and thoughtful feedback and 6 of 9 (67%) agreed that their feedback was more structured. 27 of 32 (84%) residents found that the feedback they received allowed them to tailor their studying to areas that needed improvement during the remainder of their rotation.

CONCLUSION: Mid-rotation feedback using a structured EPA-based checklist improves the frequency and quality of resident formative feedback from both a residents' and attendings' perspective.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Sheth MM, Slanetz PJ, Lewis P, et al. A Multicenter Observational Pilot Study Evaluating the Effect of Using an Entrustable Professional Activity Checklist on Resident Mid-Rotation Formative Feedback in Diagnostic Breast Imaging. Acad Radiol. 2025. PMID: 40258664. doi:10.1016/j.acra.2025.02.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。