文献速递乳腺MR

乳腺病灶T1 mapping衍生参数的诊断准确性及其与病理特征的相关性

T1 Mapping-Derived Parameters in Breast Lesions: Diagnostic Accuracy and Correlation with Pathologic Features.
PubMed 文献 · Acad Radiol · 2025-04-09

前瞻性纳入2023年8月至2024年3月接受乳腺手术及定量MRI(含ADC和T1 mapping)的患者,比较良恶性乳腺病灶的T1 mapping衍生参数与ADC值,并用ROC曲线评估分类效能。ECV的AUC略大于ADC(0.90 vs 0.89),所有参数联合诊断模型AUC最高(0.95)。在浸润性导管癌中,ECV与雌激素受体、孕激素受体表达呈正相关,与Ki-67表达呈负相关,而ADC值与预后指标无相关性。

要点

  • ECV鉴别乳腺良恶性病灶的AUC为0.90,略高于ADC的0.89。
  • 所有T1参数与ADC联合诊断模型AUC达0.95,为各模型中最高。
  • IDC中ECV与ER、PR表达正相关,与Ki-67表达负相关。

核心结论

  • T1 mapping衍生参数可有效鉴别乳腺良恶性病灶,并可能用于预测肿瘤侵袭性。

研究设计与样本

  • 前瞻性研究,纳入2023年8月至2024年3月接受乳腺手术及定量MRI(含ADC和T1 mapping)的患者;以病理为参考标准,比较良恶性病灶的T1参数(T10、T1c、ΔT1、ΔT1%、ECV)与ADC值,并用ROC曲线评估分类效能。

诊断标准与关键数值

  • ECV鉴别乳腺良恶性病灶的AUC为0.90(95% CI: 0.84-0.95),ADC的AUC为0.89(95% CI: 0.83-0.94)。
  • 所有参数联合诊断模型的AUC最高,为0.95(95% CI: 0.90-0.98)。
  • IDC中ECV与ER表达正相关(r=0.449,P<.001),与PR表达正相关(r=0.433,P<.001),与Ki-67表达负相关(r=-0.407,P<.001)。
  • ADC值与预后指标无相关性。

临床应用与阅片要点

  • 阅片时可关注ECV参数,其鉴别乳腺良恶性病灶的AUC(0.90)略高于ADC(0.89)。
  • 联合T1 mapping衍生参数与ADC可提高鉴别诊断效能(联合模型AUC 0.95)。
  • 在IDC中,ECV与ER、PR表达正相关、与Ki-67表达负相关,ADC值与预后指标无相关性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate the diagnostic potential of T1 mapping-derived parameters for distinguishing between benign and malignant breast tumors and their associations with pathologic prognostic indicators in invasive breast cancer.

MATERIALS AND METHODS: Patients who underwent breast surgery and quantitative magnetic resonance imaging (MRI), including apparent diffusion coefficient (ADC) and T1 mapping, between August 2023 and March 2024 were prospectively included. T1 parameters, including lesion T1 values before and after contrast agent injection (T10, T1c), reduction in T1 value (ΔT1), ratio of reduction (ΔT1%), extracellular volume fractions (ECVs), and ADC values were compared between benign and malignant breast lesions. The classification effect was evaluated via receiver operating characteristic (ROC) curves, and the correlation between MRI parameters and each prognostic indicator in invasive ductal carcinoma (IDC) was analyzed via Spearman correlation.

RESULTS: The ROC curves revealed that the area under the curve (AUC) of the ECV was slightly larger than that of the ADC (0.90 [95% CI: 0.84-0.95] vs 0.89 [95% CI: 0.83-0.94]). The combined diagnostic model of all parameters had the highest AUC (0.95 [95% CI: 0.90-0.98]). In IDC, ECV was positively correlated with the expression of estrogen receptor (r = 0.449, P < .001) and progesterone receptor (r = 0.433, P < .001) and negatively correlated with Ki-67 protein expression (r = -0.407, P < .001). No correlation was found between the ADC values and prognostic indicators.

CONCLUSION: T1 parameters can effectively differentiate benign and malignant breast lesions and have potential utility in predicting tumor invasiveness.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Sun S, Wang S, Tang Y, et al. T1 Mapping-Derived Parameters in Breast Lesions: Diagnostic Accuracy and Correlation with Pathologic Features. Acad Radiol. 2025. PMID: 40204585. doi:10.1016/j.acra.2025.03.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。