文献速递乳腺乳腺X线

多变量模型预测非肿块强化乳腺病灶恶性概率:基于对比增强乳腺摄影的研究

Multivariable model to predict breast cancer in non-mass enhancement lesions: a study on contrast-enhanced mammography.
PubMed 文献 · Eur Radiol · 2025-04-17

本研究纳入162例患者的206个非肿块强化(NME)病灶,按7:3随机分为训练集和测试集,利用对比增强乳腺摄影(CEM)的形态学和强化特征建立逻辑回归多变量模型预测恶性概率。恶性微钙化、段样及线样分布、簇状及簇环状强化、III型曲线与恶性相关(均p<0.002)。模型在训练集和测试集的敏感度、特异度、AUC分别为79.41-80.77%、94.44-97.37%、0.920-0.946。

要点

  • 恶性微钙化、段样/线样分布、簇状/簇环状强化、III型曲线与NME恶性相关(均p<0.002)。
  • 多变量模型在训练集和测试集的AUC分别为0.920和0.946,特异度高(94.44-97.37%)。
  • 结合微钙化和强化特征可提高CEM对NME病灶恶性诊断的效能。

核心结论

  • 联合微钙化和强化特征的多变量模型在预测恶性NME病灶时表现出可接受的敏感度和高特异度。

研究设计与样本

  • 共纳入162例患者的206个NME病灶,按7:3随机分为训练集和测试集,采用逻辑回归建立多变量模型,通过AUC评估预测价值。

关键影像表现/征象

  • 恶性微钙化、段样及线样分布、簇状及簇环状强化、III型曲线在恶性NME中发生率更高(均p<0.002)。

诊断标准与关键数值

  • 多变量模型在训练集的敏感度、特异度、AUC分别为79.41%、94.44%、0.920。
  • 多变量模型在测试集的敏感度、特异度、AUC分别为80.77%、97.37%、0.946。

临床应用与阅片要点

  • CEM多变量模型整合微钙化、强化形态分布、内部强化模式和时间-信号强度曲线,可辅助NME病灶的恶性诊断。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: To explore morphology and enhancement features of malignant non-mass enhancement (NME) lesions in contrast-enhanced mammography (CEM), and to develop a multivariable model that can accurately predict the probability of malignancy in NME lesions.

METHODS: A total of 162 patients with 206 NME lesions were enrolled. The ratio of 7:3 was randomly divided into a training data set and a test data set. Differences between benign and malignant NME diseases were compared using statistical analysis in the training data set. A logistic regression analysis was used to develop a multivariable model for predicting the probability of malignancy in the training data set. The predictive value of the model was assessed by calculating the area under the curve (AUC) in both training and test data sets.

RESULTS: The incidence of malignancy was higher in cases with malignant microcalcification (32.35%), segmental and linear distribution (55.88%), clumped and clustered ring enhancement pattern (70.59%), and Type III curve (64.71%) (all p < 0.002). The sensitivity, specificity, and AUC of the multivariable model in the training data set and the test data set were 79.41-80.77%, 94.44-97.37%, and 0.920-0.946, respectively.

CONCLUSIONS: When combining microcalcification and enhancement features, the multivariable model for CEM demonstrated acceptable sensitivity and high specificity in predicting malignant NME lesions.

KEY POINTS: Question CEM has gained momentum as an innovative and clinically useful method, but it has not been identified for the discrimination efficacy of NME lesions. Findings The multivariable model of CEM can improve the diagnostic efficiency of breast malignancy NME lesions, with acceptable sensitivity and high specificity. Clinical relevance CEM is an innovative advancement in breast imaging technology. This multivariable model of CEM integrates factors such as microcalcifications, enhancement morphological distribution, internal enhancement patterns, and time-signal intensity curves, thereby enabling accurate diagnosis of NME lesions.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Hua B, Chen J, Wang Y, et al. Multivariable model to predict breast cancer in non-mass enhancement lesions: a study on contrast-enhanced mammography. Eur Radiol. 2025. PMID: 40244408. doi:10.1007/s00330-025-11597-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。