文献速递乳腺MR

乳腺良恶性病变的鉴别:基于时间依赖性扩散MRI的微结构指标

Benign and Malignant Breast Lesions: Differentiation Using Microstructural Metrics Derived from Time-Dependent Diffusion MRI.
PubMed 文献 · Radiol Imaging Cancer · 2025-01-01

这项前瞻性研究纳入105个乳腺病灶(31个良性、74个恶性),采用时间依赖性扩散MRI的微结构指标与传统DWI的ADC进行良恶性鉴别。恶性病灶的细胞直径、细胞密度和细胞内体积分数高于良性病灶,ADC低于良性病灶;其中细胞密度的AUC为0.93,高于ADC的0.79(P=0.03)。

要点

  • 恶性病灶的细胞密度、细胞直径和细胞内体积分数高于良性病灶,ADC低于良性病灶。
  • 时间依赖性扩散MRI的细胞密度AUC为0.93,高于ADC的0.79(P=0.03)。

核心结论

  • 时间依赖性扩散MRI衍生的单一微结构指标细胞密度在鉴别乳腺良恶性病灶方面性能高于传统ADC。

研究设计与样本

  • 前瞻性研究(ClinicalTrials.gov注册号NCT05373628),纳入2022年1月至2023年6月经超声、乳腺X线或两者确认的乳腺病灶参与者,共102名女性(平均年龄48岁±12[SD])的105个病灶(3名参与者有2个病灶),包括31个良性、74个恶性;采用振荡和脉冲梯度编码的时间依赖性扩散MRI及传统扩散加权成像,时间依赖性扩散MRI数据使用有限谱编辑扩散的影像微结构参数模型拟合,以病理为良恶性分类参考标准。

诊断标准与关键数值

  • 恶性病灶的细胞密度、细胞直径和细胞内体积分数高于良性病灶,ADC低于良性病灶(P<.001至P=.001);细胞密度AUC为0.93(95%CI:0.88,0.98),高于ADC的AUC 0.79(95%CI:0.70,0.88),P=.03。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To investigate the diagnostic performance of microstructural metrics from time-dependent diffusion MRI (Td-dMRI) in distinguishing between benign and malignant breast lesions. Materials and Methods This prospective study (ClinicalTrials.gov identifier: NCT05373628) enrolled participants with breast lesions confirmed with US, mammography, or both from January 2022 to June 2023. Participants underwent oscillating and pulsed gradient encoded Td-dMRI and conventional diffusion-weighted imaging (DWI). Td-dMRI data were fitted using the imaging microstructural parameters using limited spectrally edited diffusion model. Lesions were classified as benign or malignant based on pathology. Diagnostic performances of Td-dMRI metrics and apparent diffusion coefficients (ADCs) from DWI in distinguishing between benign and malignant tumors were assessed using receiver operating characteristic analysis and compared using the DeLong test. Results The study included 102 female participants (mean age: 48 years ± 12 [SD]) with 105 breast lesions (three participants had two lesions), including 31 benign and 74 malignant lesions. The cell diameter, cell density, and intracellular volume fraction from Td-dMRI were higher and the ADC was lower in malignant lesions compared with benign lesions (P < .001 to P = .001). Among microstructural metrics from Td-dMRI, the cell density had the highest area under the receiver operating characteristic curve, which was higher than that of the ADC (0.93 [95% CI: 0.88, 0.98] vs 0.79 [95% CI: 0.70, 0.88], P = .03). Conclusion A single microstructural metric derived from Td-dMRI, cell density, had higher performance than conventional ADC in distinguishing benign and malignant breast lesions. Keywords: MR-Diffusion Weighted Imaging, Breast Clinical trial registration no. NCT05373628 Supplemental material is available for this article. © RSNA, 2025.

来源:Radiol Imaging Cancer,查看原文。版权归原作者所有。

引用

  1. Su Y, Qiu Y, Huang X, et al. Benign and Malignant Breast Lesions: Differentiation Using Microstructural Metrics Derived from Time-Dependent Diffusion MRI. Radiol Imaging Cancer. 2025. PMID: 40214515. doi:10.1148/rycan.240287

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。