囊性乳腺病变:诊断方法与超声评估
本文基于美国放射学会BI-RADS系统,阐述囊性乳腺病变的超声分类:单纯囊肿、复杂囊肿、簇状微囊肿及复杂囊实性肿块,并说明各自诊断标准、BI-RADS分类及管理建议,强调规范技术可减少不必要随访和活检,同时避免漏诊癌症。
要点
- 单纯囊肿符合无回声、圆形或椭圆形、边缘清晰、后方增强,归为BI-RADS 2类良性。
- 复杂囊肿含碎屑且除无回声外符合单纯囊肿其余标准,归为BI-RADS 3类可能良性。
- 簇状微囊肿为无实性成分的小无回声病灶簇,归为BI-RADS 2类;复杂囊实性肿块归为BI-RADS 4类并建议活检。
核心结论
- 放射科医师应规范技术仔细评估囊性乳腺病变,给出恰当评估与管理建议,以减少不必要随访和活检,同时防止癌症漏诊或忽视。
研究设计与样本
- 本文为综述,依据美国放射学会BI-RADS系统及近期研究,汇总囊性乳腺病变的超声分类、诊断标准与BI-RADS分类。
关键影像表现/征象
- 单纯囊肿超声表现为无回声、圆形或椭圆形、边缘清晰、后方增强。
- 复杂囊肿含碎屑,除无回声外符合单纯囊肿其余超声标准。
- 簇状微囊肿为簇状小无回声肿块,无实性成分。
- 复杂囊实性肿块含液体和实性成分,包括厚壁、厚分隔、囊内或壁结节及囊实性混合成分。
诊断标准与关键数值
- 单纯囊肿符合无回声、圆形或椭圆形、边缘清晰、后方增强标准,归为BI-RADS 2类良性。
- 复杂囊肿归为BI-RADS 3类可能良性。
- 簇状微囊肿归为BI-RADS 2类。
- 复杂囊实性肿块通常考虑BI-RADS 4类可疑,并建议活检。
临床应用与阅片要点
- 采用规范超声技术,依据BI-RADS超声标准对囊性乳腺病变进行分类评估。
- 单纯囊肿和簇状微囊肿归为BI-RADS 2类,复杂囊肿归为BI-RADS 3类,复杂囊实性肿块归为BI-RADS 4类并建议活检。
- 放射科医师应仔细评估囊性病变,提供恰当评估与管理建议,以减少不必要随访和活检并防止癌症漏诊。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Various cystic breast lesions are encountered during screening and diagnostic breast imaging. According to the Breast Imaging Reporting and Data System (BI-RADS) from the American College of Radiology, cystic breast lesions can be classified into the following categories based on sonographic findings: simple cysts, complicated cysts, clustered microcysts, and complex cystic and solid masses. With appropriate technique, simple cysts can be diagnosed easily by satisfying the diagnostic criteria, which include anechoic round or oval lesions with circumscribed margins and posterior enhancement on US images. Simple cysts are categorized as BI-RADS category 2, benign. Complicated cysts contain debris and satisfy all other sonographic criteria for simple cysts, except they are not anechoic. Clustered microcysts are defined as lesions comprising a cluster of small anechoic masses without a solid component. Based on recent investigations, complicated cysts are categorized as BI-RADS category 3, probably benign, whereas clustered microcysts are categorized as BI-RADS category 2. Complex cystic and solid masses contain fluid and solid components and include those with a thick wall, thick septations, an intracystic or mural mass, and both cystic and solid components. They usually are considered BI-RADS category 4, suspicious, and are accompanied by a biopsy recommendation. Radiologists must evaluate cystic lesions carefully, with meticulous technique, and provide appropriate assessment and management recommendations, thereby reducing unnecessary follow-up and biopsies while preventing cancers from being missed or dismissed. ©RSNA, 2025 Supplemental material is available for this article.
引用
- Lim HS, Lee HJ, Lee JS, et al. Cystic Breast Lesions: Diagnostic Approach and US Assessment. Radiographics. 2025. PMID: 40244873. doi:10.1148/rg.240179
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。