文献速递妇产影像泌尿生殖USMR

经阴道超声与MRI在子宫内膜癌患者术前评估肌层浸润中诊断准确性的荟萃分析

Diagnostic accuracy of TVUS and MRI in the preoperative evaluation of myometrial infiltration in patients with endometrial cancer: A meta-analysis.
PubMed 文献 · Clin Radiol · 2025-03-12

该研究通过系统综述与荟萃分析比较经阴道超声(TVUS)与MRI对子宫内膜癌肌层浸润的术前诊断准确性,纳入22项观察性研究。TVUS敏感度76%、特异度84%,MRI敏感度79%、特异度84%,AUCROC分别为0.88与0.89,两者诊断准确性相当,未检出显著发表偏倚。

要点

  • TVUS与MRI对子宫内膜癌肌层浸润的术前诊断准确性相当,AUCROC分别为0.88与0.89。
  • TVUS敏感度76%(95%CI 72-82%)、特异度84%(95%CI 79-88%)。
  • MRI敏感度79%(95%CI 73-84%)、特异度84%(95%CI 80-88%)。

核心结论

  • TVUS与MRI在子宫内膜癌患者术前评估肌层浸润方面表现出相当的诊断准确性。

研究设计与样本

  • 系统综述与荟萃分析,纳入22项比较TVUS与MRI诊断肌层浸润准确性的观察性研究,检索Web of Science、SCOPUS、MEDLINE、PubMed、Google Scholar和EMBASE数据库,发表时间范围为1964年1月至2024年6月。

诊断标准与关键数值

  • TVUS诊断肌层浸润的敏感度76%(95%CI 72-82%)、特异度84%(95%CI 79-88%)、诊断比值比18(95%CI 22-26)、AUCROC 0.88;MRI敏感度79%(95%CI 73-84%)、特异度84%(95%CI 80-88%)、诊断比值比20(95%CI 14-28)、AUCROC 0.89。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: The incidence of endometrial cancer is on the rise worldwide. Accurate preoperative evaluation of myometrial infiltration is crucial for developing treatment strategies. This study compares the diagnostic accuracy of transvaginal ultrasound (TVUS) and magnetic resonance imaging (MRI) for myometrial infiltration (MI) in endometrial cancer (EC).

MATERIALS AND METHODS: We performed a systematic review and meta-analysis of observational studies, identified by screening Web of Science, SCOPUS, MEDLINE, PubMed, Google Scholar, and EMBASE databases. Studies published between January 1964 and June 2024 comparing the diagnostic accuracy of TVUS and MRI for MI were included. The data analysis focused on sensitivity, specificity, and overall diagnostic accuracy.

RESULTS: Twenty-two studies in EC patients were included. The diagnostic odds ratio (OR) for TVUS and for MRI was 18 (95% CI: 22-26) and 20 (95% CI: 14-28), respectively. TVUS was associated with a sensitivity and specificity of 76% (95% CI: 72-82%) and 84% (95% CI: 79-88%), respectively, while MRI had a sensitivity and specificity of 79% (95% CI: 73-84%) and 84% (95% CI: 80-88%), respectively. The area under the receiver operating characteristic curve (AUCROC) was 0.88 for TVUS and 0.89 for MRI. No significant publication bias was detected.

CONCLUSIONS: Both TVUS and MRI demonstrated comparable diagnostic accuracy for the preoperative evaluation of MI in EC.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Jin Y, Zhou C. Diagnostic accuracy of TVUS and MRI in the preoperative evaluation of myometrial infiltration in patients with endometrial cancer: A meta-analysis. Clin Radiol. 2025. PMID: 40215804. doi:10.1016/j.crad.2025.106868

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。