回顾性分析31例经手术证实子宫内膜癌患者的术前盆腔MRI扩散加权成像,比较常规单次激发平面回波成像、深度学习重建单次激发平面回波成像与多次激发平面回波成像(MUSE)的图像质量与诊断准确性。深度学习重建序列在整体图像质量、子宫边缘锐利度、病灶显示清晰度、噪声、信噪比及对比噪声比方面优于常规序列,与MUSE无显著差异。深度学习重建序列对深肌层浸润的诊断准确率与常规序列及MUSE无显著差异。

要点

  • 深度学习重建单次激发平面回波扩散加权成像的图像质量与多次激发平面回波成像(MUSE)相当。
  • 深度学习重建序列噪声低于常规单次激发序列,信噪比和对比噪声比高于常规序列。
  • 三种扩散加权序列对深肌层浸润的诊断准确率无显著差异。

核心结论

  • 深度学习重建可改善子宫内膜癌扩散加权成像的图像质量,图像质量与MUSE相当,且扫描时间显著缩短。

研究设计与样本

  • 回顾性分析31例经手术证实子宫内膜癌患者的术前盆腔MRI扩散加权成像,比较常规单次激发平面回波成像、深度学习重建单次激发平面回波成像与MUSE三种序列。

关键影像表现/征象

  • 深度学习重建单次激发平面回波成像的整体图像质量评分高于常规单次激发序列(p < 0.001),与MUSE无显著差异(p > 0.05)。
  • 深度学习重建序列的子宫边缘锐利度评分高于常规序列(p < 0.001),与MUSE无显著差异(p > 0.05)。
  • 深度学习重建序列的病灶显示清晰度评分高于常规序列(p < 0.001),与MUSE无显著差异(p > 0.05)。

诊断标准与关键数值

  • 深度学习重建序列噪声低于常规单次激发序列(p < 0.001),与MUSE无显著差异(p > 0.05)。
  • 深度学习重建序列信噪比和对比噪声比高于常规单次激发序列(p < 0.001),与MUSE相当(p > 0.05)。
  • 常规单次激发、深度学习重建单次激发与MUSE三种序列对深肌层浸润的诊断准确率无显著差异(p > 0.05)。

临床应用与阅片要点

  • 深度学习重建单次激发平面回波扩散加权成像可作为女性盆腔MRI中MUSE的替代方案,并具有扫描时间显著缩短的优势。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the efficacy of deep learning reconstruction (DLR) in diffusion-weighted imaging (DWI) with single-shot echo-planar imaging (SSEPI) for endometrial cancer, compared to multiplexed sensitivity-encoding (MUSE) DWI.

METHODS: We retrospectively reviewed 31 women with surgically confirmed endometrial cancer who underwent preoperative pelvic magnetic resonance imaging (MRI) including DWI. Qualitative analysis including overall image quality, susceptibility artifacts, sharpness of the uterine edge, and lesion conspicuity were compared among conventional SSEPI (SSEPI-C), SSEPI with DLR (SSEPI-DL), and MUSE using the Friedman's test. Quantitative analysis including the apparent diffusion coefficient (ADC) values, noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were also compared among three DWI sequences using the Friedman's test. In addition, the diagnostic accuracy for deep myometrial invasion was compared to three DWI sequences using Cochran's Q test.

RESULTS: The scores of overall image quality, sharpness of the uterine edge, and lesion conspicuity in SSEPI-DL were higher than SSEPI-C (p < 0.001) with no significant difference compared to MUSE (p > 0.05). Noise in SSEPI-DL was lower than SSEPI-C (p < 0.001), with no significant difference compared to MUSE (p > 0.05). SNR and CNR in SSEPI-DL were also superior to SSEPI-C (p < 0.001), and comparable to MUSE (p > 0.05). The diagnostic accuracy for detecting deep myometrial invasion showed no significant difference among SSEPI-C, SSEPI-DL and MUSE (p > 0.05).

CONCLUSION: DLR improves the image quality of DWI in endometrial cancer, demonstrating image quality equivalent to that of SSEPI-DL and MUSE. SSEPI-DL can be an alternative to MUSE in female pelvic MRI, with the benefit of significantly shortened scan time.