多参数MRI评估伴微囊、拉长与碎片状浸润模式的子宫内膜癌
这项回顾性单中心病例对照研究纳入85例子宫内膜癌患者(其中17例伴MELF模式),由三位放射科医生评估术前MRI的DWI信号分级与DWI-CE不匹配(DG-DCM)及肿瘤-肌层同步早期强化(TME)。结论认为伴MELF的子宫内膜癌可能表现出DG-DCM和TME特征性MRI表现,DWI与DCE对检出MELF模式浸润的深肌层侵犯可能具有较高价值。
要点
- 伴MELF的子宫内膜癌可能表现出DG-DCM与TME两种特征性MRI征象。
- 诊断MELF模式深肌层侵犯时,在T2WI+CE基础上加做DWI+DCE可提高敏感度。
- 无MELF的肿瘤加做DWI+DCE后敏感度、特异度与准确率均未改变。
核心结论
- 伴MELF的子宫内膜癌可能表现出DG-DCM和TME特征性MRI表现,DWI与DCE对检出MELF模式浸润的深肌层侵犯可能具有较高价值。
研究设计与样本
- 回顾性单中心病例对照研究,纳入2020年12月至2023年1月间85例子宫内膜癌患者,其中17例伴MELF,术前MRI包括T2WI、DWI及动态增强(DCE)与平衡期增强(CE),由三位放射科医生阅片,以病理为参考标准。
关键影像表现/征象
- 伴MELF的子宫内膜癌可能表现出DWI信号分级与DWI-CE不匹配(DG-DCM)以及肿瘤-肌层同步早期强化(TME)两种MRI征象。
诊断标准与关键数值
- 三位阅片者诊断MELF的DG-DCM敏感度为41.2-76.5%、特异度为89.7-98.5%;TME敏感度为70.7-82.4%、特异度为94.1-95.6%。
临床应用与阅片要点
- 在T2WI+CE基础上加做DWI+DCE后,诊断伴MELF的深肌层侵犯时,阅片者1敏感度由16.7%升至91.7%、阅片者2由16.7%升至83.3%(p<0.01),阅片者1准确率由35.3%升至82.4%(p<0.01);无MELF肿瘤加做DWI+DCE后敏感度、特异度与准确率均未改变。
局限性
- 原文为回顾性单中心病例对照研究。
- 伴MELF者仅17例,样本量小。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the MRI findings of endometrial cancer with microcystic, elongated, and fragmented (MELF) pattern invasion and to evaluate the optimal sequences to detect deep myometrial invasion with MELF.
MATERIALS AND METHODS: This retrospective single-center case-control study included 85 patients with endometrial cancer, including 17 patients with MELF, between December 2020 and January 2023. Preoperative MRI, including T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), and dynamic contrast-enhanced (DCE) with equilibrium phase contrast-enhanced (CE) MRI were reviewed by three radiologists. DWI signal gradation with DWI-CE mismatch (DG-DCM) and tumor-myometrium synchronous early enhancement (TME) were evaluated, as well as the diagnostic performance for deep myometrial invasion, first with T2WI + CE alone and then with the addition of DWI + DCE. Pathology was used as the reference standard.
RESULTS: The sensitivity and specificity of DG-DCM were 41.2-76.5% and 89.7-98.5%, and those of TME were 70.7-82.4% and 94.1-95.6%, respectively, for MELF by the three readers. For the diagnosis of deep myometrial invasion with MELF, the addition of DWI + DCE to T2WI + CE significantly improved the sensitivity for two readers (from 16.7 to 91.7% for Reader 1, from 16.7 to 83.3% for Reader 2, p < 0.01) and the accuracy for one reader (from 35.3 to 82.4% for Reader 1, p < 0.01). In contrast, sensitivity, specificity and accuracy did not change with the addition of DWI + DCE in tumors without MELF.
CONCLUSION: Endometrial cancer with MELF may show characteristic MRI findings of DG-DCM and TME. The value of DWI and DCE in detecting deep myometrial invasion may be high for MELF pattern invasion.
引用
- Kaketaka K, Tsuboyama T, Fukui H, et al. Assessment of endometrial cancer with microcystic, elongated, and fragmented pattern invasion using multiparametric MRI. Abdom Radiol (NY). 2025. PMID: 40237809. doi:10.1007/s00261-025-04937-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。