开发并验证一种人工智能模型以提升初级超声医师对深部浸润型子宫内膜异位症的诊断能力
本研究基于超声视频和图像开发并验证人工智能模型,用于提升初级超声医师检测深部浸润型子宫内膜异位症的表现。模型训练使用248张图像,测试集mAP50为0.9779。在147张图像评估中,两位初级超声医师的AUROC分别从0.748和0.713提升至0.878和0.798(均p<0.0001),敏感度最大提升从77.42%至94.35%。
要点
- AI-DE模型基于YOLOv8训练,测试集mAP50达0.9779,可辅助检测盆腔深部浸润型子宫内膜异位症结节。
- 初级超声医师A的AUROC从0.748(95%CI 0.624-0.867)提升至0.878(95%CI 0.792-0.964),p<0.0001。
- 初级超声医师B的AUROC从0.713(95%CI 0.592-0.835)提升至0.798(95%CI 0.677-0.919),p<0.0001。
核心结论
- 基于超声图像的AI-DE模型在检测深部浸润型子宫内膜异位症方面表现良好,并显著提升了初级超声医师的诊断性能。
研究设计与样本
- 回顾性研究,收集接受超声检查且患有深部浸润型子宫内膜异位症的女性患者数据;AI-DE模型采用YOLOv8训练,训练集248张图像,测试集mAP50为0.9779;另用147张图像评估初级超声医师在有和无AI模型辅助下的诊断性能。
诊断标准与关键数值
- AI-DE模型测试集mAP50(IoU阈值0.5时的平均精度均值)为0.9779。
- 初级超声医师A的AUROC从0.748(95%CI 0.624-0.867)提升至0.878(95%CI 0.792-0.964),p<0.0001。
- 初级超声医师B的AUROC从0.713(95%CI 0.592-0.835)提升至0.798(95%CI 0.677-0.919),p<0.0001。
- 两位超声医师的敏感度均显著提高,最大提升从77.42%至94.35%。
临床应用与阅片要点
- AI-DE模型可辅助初级超声医师检测盆腔深部浸润型子宫内膜异位症结节,提升诊断性能。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: This study aims to develop and validate an artificial intelligence (AI) model based on ultrasound (US) videos and images to improve the performance of junior sonologists in detecting deep infiltrating endometriosis (DE).
METHODS: In this retrospective study, data were collected from female patients who underwent US examinations and had DE. The US image records were divided into two parts. First, during the model development phase, an AI-DE model was trained employing YOLOv8 to detect pelvic DE nodules. Subsequently, its clinical applicability was evaluated by comparing the diagnostic performance of junior sonologists with and without AI-model assistance.
RESULTS: The AI-DE model was trained using 248 images, which demonstrated high performance, with a mAP50 (mean Average Precision at IoU threshold 0.5) of 0.9779 on the test set. Total 147 images were used for evaluate the diagnostic performance. The diagnostic performance of junior sonologists improved with the assistance of the AI-DE model. The area under the receiver operating characteristic (AUROC) curve improved from 0.748 (95% CI, 0.624-0.867) to 0.878 (95% CI, 0.792-0.964; p < 0.0001) for junior sonologist A, and from 0.713 (95% CI, 0.592-0.835) to 0.798 (95% CI, 0.677-0.919; p < 0.0001) for junior sonologist B. Notably, the sensitivity of both sonologists increased significantly, with the largest increase from 77.42% to 94.35%.
CONCLUSION: The AI-DE model based on US images showed good performance in DE detection and significantly improved the diagnostic performance of junior sonologists.
引用
- Xu J, Zhang A, Zheng Z, et al. Development and Validation an AI Model to Improve the Diagnosis of Deep Infiltrating Endometriosis for Junior Sonologists. Ultrasound Med Biol. 2025. PMID: 40251088. doi:10.1016/j.ultrasmedbio.2025.03.012