文献速递泌尿生殖US

不同程度睾丸损伤兔模型的超声造影结果、血管内皮细胞损伤及氧化应激指标变化

Changes in Contrast-Enhanced Ultrasonography Results, Vascular Endothelial Cell Damage, and Oxidative Stress Indicators in Rabbit Models With Varying Degrees of Testicular Injury.
PubMed 文献 · J Ultrasound Med · 2025-04-17

本研究用新西兰雄兔建立睾丸挫伤、血肿、破裂及对照模型,于建模后即刻、2、4、6小时行常规超声与超声造影,并以病理证实。结果显示造影时间-强度曲线的到达时间、达峰时间、曲线下面积组间差异有统计学意义,血清vWF、ROS、NO、ET-1组间差异亦有统计学意义,作者认为上述指标可较准确区分睾丸损伤程度。

要点

  • 超声造影的到达时间、达峰时间、曲线下面积在挫伤、血肿、破裂与对照模型间差异有统计学意义。
  • 峰值强度在血肿组与峰值强度指标之间无显著差异(F=0.172,P=.92)。
  • 血清vWF、ROS、NO、ET-1组间差异有统计学意义,可能作为评估睾丸损伤程度的生物标志物。

核心结论

  • 作者认为超声造影的到达时间、达峰时间、曲线下面积能更准确地区分睾丸损伤程度。
  • 作者认为氧化应激与内皮细胞损伤指标也可能作为评估睾丸损伤程度的生物标志物。

研究设计与样本

  • 研究类型为动物实验,以新西兰雄兔建立睾丸钝性损伤模型,包括挫伤、血肿、破裂与对照模型。
  • 建模后即刻、2、4、6小时行常规超声与超声造影检查,并以病理检查进一步确认建模结果。
  • 检测血清von Willebrand因子(vWF)、内皮素-1(ET-1)、活性氧(ROS)和一氧化氮(NO)水平。

关键影像表现/征象

  • 超声造影时间-强度曲线的到达时间组间差异有统计学意义(F=35.159,P<.001)。
  • 达峰时间组间差异有统计学意义(F=122.434,P<.001)。
  • 曲线下面积组间差异有统计学意义(F=47.444,P<.001)。
  • 峰值强度在血肿组与峰值强度指标之间无显著差异(F=0.172,P=.92)。

诊断标准与关键数值

  • 超声造影定量参数到达时间(F=35.159,P<.001)、达峰时间(F=122.434,P<.001)、曲线下面积(F=47.444,P<.001)在挫伤、血肿、破裂与对照模型间差异有统计学意义。
  • 血清vWF(F=40.61,P<.001)、ROS(F=106.3,P<.001)、NO(F=79.3,P<.001)、ET-1(F=61.94,P<.001)水平组间差异有统计学意义。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: It is difficult to quickly assess the degree of testicular injury in patients with blunt testicular trauma, and accurate and rapid assessment of the degree of injury is related to clinical decision-making and treatment outcomes. This study explored the sonographic characteristics of patients with different degrees of blunt testicular trauma via contrast-enhanced ultrasound (CEUS), as well as biomarkers of oxidative stress and vascular endothelial cell injury, to further evaluate the diagnostic value of these parameters in blunt testicular trauma.

METHOD: New Zealand male rabbits were used to establish blunt testicular trauma models of different degrees, including contusion, hematoma, rupture, and control models. Routine ultrasound and CEUS were performed immediately, 2, 4, and 6 h after modeling, and pathological examination was used to confirm the modeling results further. The levels of von Willebrand factor (vWF), endothelin-1 (ET-1), reactive oxygen species (ROS), and nitric oxide (NO) in the serum were analyzed.

RESULTS: According to the CEUS results, the arrival time (AT) (F = 35.159, P < .001), time to peak intensity (TTP) (F = 122.434; P < .001), and area under the curve (AUC) (F = 47.444; P < .001) of the time-intensity curves showed significant differences among the groups. There was no significant difference between Hematoma Trauma (HT) (F = 0.178; P = .91) and Peak Intensity (PI) (F = 0.172; P = .92). For biomarkers, there were significant differences in vWF (F = 40.61; P < .001), ROS (F = 106.3; P < .001), NO (F = 79.3; P < .001), and ET-1 (F = 61.94; P < .001) levels among the groups.

CONCLUSIONS: For blunt testicular trauma, the AT, TTP, and AUC indices of CEUS can more accurately distinguish the degree of testicular injury. Oxidative stress and endothelial cell damage may also be used as biomarkers for evaluating the degree of testicular injury.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Zhao Y, Wang H, Su G, et al. Changes in Contrast-Enhanced Ultrasonography Results, Vascular Endothelial Cell Damage, and Oxidative Stress Indicators in Rabbit Models With Varying Degrees of Testicular Injury. J Ultrasound Med. 2025. PMID: 40241679. doi:10.1002/jum.16704

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。