文献速递腹部泌尿生殖MR

优化膀胱磁共振成像:通过深度学习加速扫描时间并提高图像质量

Optimizing bladder magnetic resonance imaging: accelerating scan time and improving image quality through deep learning.
PubMed 文献 · Abdom Radiol (NY) · 2025-04-01

前瞻性纳入28例连续膀胱癌评估患者,比较标准T2加权TSE序列与深度学习重建T2序列的采集时间、图像质量和诊断信心。T2DL在轴向采集时间减少49.4%、冠状和矢状减少43.8%,伪影和噪声更优,轴向和矢状整体图像质量更高,诊断信心和VI-RADS T2评分无差异。

要点

  • 深度学习重建T2序列较标准TSE序列轴向采集时间减少49.4%、冠状和矢状减少43.8%。
  • T2DL在伪影严重程度和噪声水平上优于T2S(均p<0.05)。
  • 两序列在各平面的诊断信心和VI-RADS T2评分无差异(p>0.05)。

核心结论

  • 本研究初步证明深度学习重建T2加权膀胱MR在临床实践中的可行性,T2DL在减少采集时间的同时获得优于标准T2 TSE序列的病灶可检测性和整体图像质量,诊断信心和T2评分相似。

研究设计与样本

  • 前瞻性研究纳入28例连续膀胱癌评估患者,每位患者行三个平面的T2S和T2DL序列,比较采集时间,由两名放射科医生独立采用5分Likert量表评估伪影、噪声、整体图像质量和诊断信心,并进行VI-RADS T2评分。

关键影像表现/征象

  • 与T2S相比,T2DL轴向采集时间减少49.4%,冠状和矢状采集时间减少43.8%。
  • T2DL的伪影严重程度和影响以及噪声水平优于T2S(均p<0.05)。
  • T2DL在轴向和矢状成像的整体图像质量高于T2S(均p<0.05)。

诊断标准与关键数值

  • 图像质量评估采用5分Likert量表,5分表示最佳质量。
  • T2评分基于VI-RADS系统,由两名读者完成。
  • 诊断信心和T2评分在T2DL与T2S之间各平面均无差异(p>0.05)。

局限性

  • 本研究为初步研究,样本量为28例连续患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate the value of deep learning (DL) in T2-weighted imaging (T2DL) of the bladder regarding acquisition time (TA), image quality, and diagnostic confidence compared to standard T2-weighted turbo-spin-echo (TSE) imaging (T2S).

METHODS: We prospectively enrolled a total of 28 consecutive patients for the evaluation of bladder cancer. T2S and T2DL sequences in three planes were performed for each participant, and acquisition time was compared between the two acquisition protocols. The image evaluation was conducted independently by two radiologists using a 5-point Likert scale for artifacts, noise, overall image quality, and diagnostic confidence, with 5 indicating the best quality. Additionally, T2 scoring based on Vesical Imaging-Reporting and Data System (VI-RADS) was performed by two readers.

RESULTS: Compared to T2S, the acquisition time of T2DL was reduced by 49.4% in the axial and by 43.8% in the coronal and sagittal orientations. The severity and impact of artifacts and noise levels were superior in T2DL versus T2S (both p < 0.05). The overall image quality in T2DL was demonstrated to be higher compared to that in T2S in axial and sagittal imaging (both p < 0.05). The diagnostic confidence and T2 scoring of both sequences in all planes did not differ (p > 0.05).

CONCLUSIONS: Our study preliminarily demonstrated the feasibility of T2-weighted imaging with DL reconstruction of bladder MR in clinical practice. T2DL achieved a reduction in acquisition time, superior lesion detectability, and overall image quality with similar diagnostic confidence and T2 score compared to the standard T2 TSE sequence.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Guo E, Chen L, Xu L, et al. Optimizing bladder magnetic resonance imaging: accelerating scan time and improving image quality through deep learning. Abdom Radiol (NY). 2025. PMID: 40167648. doi:10.1007/s00261-025-04895-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。