推进日常实践中的子宫内膜异位症检测:深度学习增强的多序列MRI分析模型
研究纳入病理确诊子宫内膜异位症患者395例与年龄匹配对照356例,利用矢状位脂肪饱和T1加权增强前后及T2加权MRI构建3D-DenseNet-121分类模型,集成方法在测试集获得F1评分0.881、AUROCC 0.911、敏感度0.976、特异度0.720,放射科医生借助AI后敏感度由84.48%升至87.93%,结论认为该模型识别子宫内膜异位症的表现与受训读片者相当。
要点
- 模型采用T2W、T1W FS增强前后三序列组合时预测最准确。
- 测试集集成模型敏感度0.976、特异度0.720、AUROCC 0.911。
- 放射科医生无AI辅助敏感度84.48%,有AI辅助87.93%。
核心结论
- 作者结论认为,这是首个在大队列中使用多序列MRI的深度学习模型,在识别子宫内膜异位症方面显示与受训读片者相当的人体检测结果。
研究设计与样本
- 研究为基于本机构数据库的队列研究,纳入2015年至2024年病理确诊子宫内膜异位症患者395例及接受相似MR方案的无子宫内膜异位症诊断的年龄匹配对照组356例,使用矢状位脂肪饱和T1加权增强前后及T2加权MRI,数据集按患者层面划分12.5%用于测试,其余进行七折交叉验证。
诊断标准与关键数值
- 最终3D-DenseNet-121分类器模型在使用T2W、T1W FS增强前和增强后图像时获得最准确预测,测试集集成方法F1评分为0.881、AUROCC为0.911、敏感度为0.976、特异度为0.720。
临床应用与阅片要点
- 放射科医生在无AI辅助时检测子宫内膜异位症的敏感度为84.48%,在有AI辅助时为87.93%;读片者间预测标签的一致性Fleiss kappa在无AI辅助时为0.5718,在有AI辅助时为0.6839。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Endometriosis affects 5-10% of women of reproductive age. Despite its prevalence, diagnosing endometriosis through imaging remains challenging. Advances in deep learning (DL) are revolutionizing the diagnosis and management of complex medical conditions. This study aims to evaluate DL tools in enhancing the accuracy of multi-sequence MRI-based detection of endometriosis.
METHOD: We gathered a patient cohort from our institutional database, composed of patients with pathologically confirmed endometriosis from 2015 to 2024. We created an age-matched control group that underwent a similar MR protocol without an endometriosis diagnosis. We used sagittal fat-saturated T1-weighted (T1W FS) pre- and post-contrast and T2-weighted (T2W) MRIs. Our dataset was split at the patient level, allocating 12.5% for testing and conducting seven-fold cross-validation on the remainder. Seven abdominal radiologists with experience in endometriosis MRI and complex surgical planning and one women's imaging fellow with specific training in endometriosis MRI reviewed a random selection of images and documented their endometriosis detection.
RESULTS: 395 and 356 patients were included in the case and control groups respectively. The final 3D-DenseNet-121 classifier model demonstrated robust performance. Our findings indicated the most accurate predictions were obtained using T2W, T1W FS pre-, and post-contrast images. Using an ensemble technique on the test set resulted in an F1 Score of 0.881, AUROCC of 0.911, sensitivity of 0.976, and specificity of 0.720. Radiologists achieved 84.48% and 87.93% sensitivity without and with AI assistance in detecting endometriosis. The agreement among radiologists in predicting labels for endometriosis was measured as a Fleiss' kappa of 0.5718 without AI assistance and 0.6839 with AI assistance.
CONCLUSION: This study introduced the first DL model to use multi-sequence MRI on a large cohort, showing results equivalent to human detection by trained readers in identifying endometriosis.
引用
- Moassefi M, Faghani S, Colak C, et al. Advancing endometriosis detection in daily practice: a deep learning-enhanced multi-sequence MRI analytical model. Abdom Radiol (NY). 2025. PMID: 40232413. doi:10.1007/s00261-025-04942-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。