文献速递技术与安全骨肌腹部CTDXA

全身双能X线吸收法与全身CT测量四肢和腹部脂肪质量及去脂体重的直接区域比较

Direct regional comparison of whole-body dual-energy X-ray absorptiometry and whole-body CT measurements of fat mass and fat-free mass in limbs and abdomen.
PubMed 文献 · Br J Radiol · 2025-01-01

本研究纳入58名20-69岁健康成人,同期行全身DXA与除头部外的全身CT,比较四肢和腹部脂肪质量与去脂体重的区域测量值。DXA所测四肢总脂肪质量和腹部节段脂肪质量显著低于CT,四肢总去脂体重高于CT(P < .001),但两者相关性很强(四肢总脂肪质量r = 0.951,四肢总去脂体重r = 0.992,腹部节段脂肪质量r = 0.984,内脏脂肪r = 0.861,均P < .001)。作者认为结果支持DXA用于分析四肢和腹部脂肪质量与去脂体重的可靠性。

要点

  • DXA所测四肢总脂肪质量和腹部节段脂肪质量显著低于CT所测值(P < .001)。
  • DXA所测四肢总去脂体重高于CT所测值(P < .001)。
  • 四肢总脂肪质量r = 0.951、四肢总去脂体重r = 0.992、腹部节段脂肪质量r = 0.984、内脏脂肪r = 0.861(均P < .001)。

核心结论

  • 全身DXA与CT在四肢和腹部脂肪质量及去脂体重的直接区域比较中呈很强相关性,支持DXA用于分析四肢和腹部脂肪质量与去脂体重的可靠性。

研究设计与样本

  • 研究纳入58名20-69岁健康成人,均接受全身DXA和除头部以外的全身CT检查,CT采用图像分割进行身体成分分析。

关键影像表现/征象

  • DXA所测四肢总脂肪质量和腹部节段脂肪质量显著低于CT所测脂肪质量(P < .001)。
  • DXA所测四肢总去脂体重高于CT所测去脂体重(P < .001)。

诊断标准与关键数值

  • 四肢总脂肪质量DXA与CT相关系数r = 0.951(P < .001)。
  • 四肢总去脂体重DXA与CT相关系数r = 0.992(P < .001)。
  • 腹部节段脂肪质量DXA与CT相关系数r = 0.984(P < .001)。
  • 内脏脂肪DXA与CT相关系数r = 0.861(P < .001)。

临床应用与阅片要点

  • 作者认为研究结果支持DXA用于分析四肢和腹部脂肪质量与去脂体重的可靠性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To measure fat mass (FM) and fat-free mass (FFM) in the limbs and abdomen using whole-body dual-energy X-ray absorptiometry (DXA) and compare them with whole-body computed tomography (CT), emphasizing precise regional comparisons to demonstrate the correlation between the methods.

METHODS: Fifty-eight healthy adults (aged 20-69) who underwent both whole-body DXA and whole-body CT were included in this study. The CT scans included the entire body except the head, and image segmentation was employed for body composition analysis. Total limb FM, FFM, segmental abdominal FM, and visceral adipose tissue (VAT) were measured from both DXA and CT.

RESULTS: The DXA-derived total limb FM and segmental abdominal FM were significantly lower than the CT-derived FM, whereas the DXA-derived total limb FFM was higher than the CT-derived FFM (P < .001). Despite these differences, very strong positive correlations were observed between DXA and CT for total limb FM (r = 0.951), total limb FFM (r = 0.992), and segmental abdominal FM (r = 0.984) (P < .001). The correlation for VAT was also strong (r = 0.861) (P < .001).

CONCLUSIONS: Our study demonstrated very strong correlation in direct regional comparisons between whole-body DXA and CT, supporting the reliability of DXA for analysing FM and FFM in the limbs and abdomen.

ADVANCES IN KNOWLEDGE: We compared FM and FFM in the limbs and abdomen between whole-body DXA and CT through a region-by-region comparison, demonstrating a more direct correlation between the 2 methods.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Oh J, Chae HD, Yoo HJ, et al. Direct regional comparison of whole-body dual-energy X-ray absorptiometry and whole-body CT measurements of fat mass and fat-free mass in limbs and abdomen. Br J Radiol. 2025. PMID: 40198228. doi:10.1093/bjr/tqaf079

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。