二维剪切波弹性成像与振动控制瞬时弹性成像评估代谢功能障碍相关脂肪性肝病肝纤维化的前瞻性比较
本研究前瞻性纳入91例疑似代谢功能障碍相关脂肪性肝病且计划行肝活检的患者,同日行振动控制瞬时弹性成像(VCTE)和二维剪切波弹性成像(2D-SWE),以肝活检为金标准。2D-SWE诊断肝纤维化(F≥1)和显著纤维化(F≥2)的AUC分别为0.92和0.93,VCTE分别为0.84和0.90,两者诊断性能无统计学显著差异(P分别为0.09和0.44)。
要点
- 2D-SWE诊断MASLD肝纤维化F≥1的AUC为0.92,切值6.1 kPa时敏感度87.8%、特异度85.3%。
- 2D-SWE诊断显著纤维化F≥2的AUC为0.93,切值7.66 kPa时敏感度84%、特异度94%。
- 2D-SWE与VCTE诊断肝纤维化及显著纤维化的性能无统计学显著差异。
核心结论
- 2D-SWE对MASLD患者肝纤维化和显著纤维化具有高诊断准确性,性能与VCTE相当。
研究设计与样本
- 前瞻性研究,纳入91例疑似MASLD且计划行肝活检的参与者(平均年龄42±13岁,男性52例),于2024年6月至2024年12月在本院临床试验中心入组。
- 所有参与者均在肝活检同日接受VCTE和2D-SWE检查,以肝活检作为评估纤维化的金标准。
- 采用受试者工作特征(ROC)曲线分析诊断准确性。
诊断标准与关键数值
- 2D-SWE诊断肝纤维化(F≥1)的AUC为0.92(95%CI:0.83-0.97),最佳切值6.1 kPa,敏感度87.8%,特异度85.3%。
- 2D-SWE诊断显著纤维化(F≥2)的AUC为0.93(95%CI:0.85-0.98),最佳切值7.66 kPa,敏感度84%,特异度94%。
- VCTE诊断肝纤维化(F≥1)的AUC为0.84(95%CI:0.74-0.91),切值6.3 kPa,敏感度92.7%,特异度64.7%。
- VCTE诊断显著纤维化(F≥2)的AUC为0.90(95%CI:0.81-0.96),切值8.1 kPa,敏感度76%,特异度90%。
- 2D-SWE与VCTE诊断肝纤维化(P=0.09)和显著纤维化(P=0.44)的性能差异无统计学显著差异。
临床应用与阅片要点
- 2D-SWE可作为MASLD患者肝纤维化评估的弹性成像方法,其诊断性能与VCTE相当。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: This prospective study aimed to compare the diagnostic performance of 2D-shear wave elastography (2D-SWE) with vibration-controlled transient elastography (VCTE) for assessing liver fibrosis in patients with metabolic dysfunction-associated steatotic liver disease (MASLD).
MATERIALS AND METHODS: Ninety-one participants (mean age: 42±13 years; 52 males) suspected of MASLD and scheduled for liver biopsy were enrolled at the Clinical Trial Center of our hospital between June 2024 and December 2024. All participants underwent both VCTE and 2D-SWE examinations on the same day as their liver biopsy, which served as the gold standard for assessing fibrosis. Diagnostic accuracy was analyzed using receiver operating characteristic (ROC) curves.
RESULTS: The areas under the ROC curves (AUCs) for 2D-SWE in diagnosing liver fibrosis (F ≥ 1) and significant fibrosis (F ≥ 2) were 0.92 (95% CI: 0.83-0.97) and 0.93 (95% CI: 0.85-0.98), respectively. The optimal cutoff values were 6.1 kPa and 7.66 kPa, yielding sensitivities of 87.8% and 84% and specificities of 85.3% and 94%, respectively. For VCTE, the AUCs were 0.84 (95% CI: 0.74-0.91) and 0.90 (95% CI: 0.81-0.96), with cutoff values of 6.3 kPa and 8.1 kPa, sensitivities of 92.7% and 76%, and specificities of 64.7% and 90%, respectively. No statistically significant difference was observed in the diagnostic performances of 2D-SWE and VCTE for liver fibrosis or significant fibrosis, with P-values of 0.09 and 0.44, respectively.
CONCLUSION: 2D-SWE demonstrated high diagnostic accuracy for detecting liver fibrosis and significant fibrosis in MASLD patients, performing comparably to VCTE.
引用
- Li Q, Gao Y, Wang D, et al. Prospective Comparison of 2D-Shear Wave Elastography and Vibration-Controlled Transient Elastography in Assessing Liver Fibrosis in Metabolic Dysfunction-Associated Steatotic Liver Disease. Acad Radiol. 2025. PMID: 40280829. doi:10.1016/j.acra.2025.04.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。