双能CT获得的肝脏细胞外容积分数:3分钟与5分钟延迟期的比较及与临床数据的相关性
本研究纳入80例慢性肝病患者,比较双能CT 3分钟与5分钟延迟期计算肝脏细胞外容积分数(ECV)的差异,并分析其与ALBI评分/分级、Fib-4及临床纤维化分期的相关性。结果显示两期ECV值无显著差异(P=0.056),3分钟与5分钟延迟期ECV比值0.984±0.078,两期ECV均与ALBI分级/评分呈强至中度相关,与Fib-4及临床纤维化分期呈中度相关。结论认为3分钟延迟期与5分钟延迟期计算ECV等效。
要点
- 双能CT 3分钟与5分钟延迟期计算的肝脏ECV值无显著差异(P=0.056)。
- 3分钟与5分钟延迟期ECV比值0.984±0.078,范围0.85~1.16。
- 3分钟延迟期ECV与ALBI分级相关系数ρ=0.763,与ALBI评分ρ=0.707。
核心结论
- 3分钟延迟期图像在计算肝脏ECV方面与5分钟延迟期图像等效。
研究设计与样本
- 2020年1月至2022年7月连续纳入80例慢性肝病患者(男45例、女35例,平均年龄69.3±10.4岁),均行3分钟和5分钟延迟期双能CT扫描以评估局灶性肝脏病变;ECV由肝实质和主动脉的碘密度计算,并与ALBI评分/分级、Fib-4及临床纤维化分期进行相关性分析。
关键影像表现/征象
- 3分钟与5分钟延迟期图像计算的ECV值无显著差异(P=0.056)。
- 3分钟与5分钟延迟期ECV值比值为0.984±0.078,范围0.85至1.16。
诊断标准与关键数值
- 3分钟延迟期ECV与ALBI分级呈强相关(Spearman ρ=0.763),与ALBI评分呈强相关(ρ=0.707)。
- 5分钟延迟期ECV与ALBI分级呈强相关(Spearman ρ=0.724),与ALBI评分呈中度相关(ρ=0.668)。
- 3分钟延迟期ECV与Fib-4呈中度相关(Spearman ρ=0.548),与临床纤维化分期呈中度相关(ρ=0.468)。
- 5分钟延迟期ECV与Fib-4呈中度相关(Spearman ρ=0.543),与临床纤维化分期呈中度相关(ρ=0.435)。
临床应用与阅片要点
- 3分钟延迟期图像可用于计算肝脏ECV,与5分钟延迟期等效,可能便于临床日常实践中使用肝脏ECV。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study aimed to compare 3-min delayed phase images with 5-min delayed phase images for quantifying hepatic extracellular volume fraction (ECV) using dual-energy CT.
METHODS: Between January 2020 and July 2022, 80 consecutive patients with chronic liver disease (45 men and 35 women, mean age: 69.3 ± 10.4 years) were included in this study cohort. All patients underwent both 3- and 5-min delayed phase CT scans for assessing focal liver lesions. Extracellular volume fraction value was calculated by the iodine densities of the hepatic parenchyma and aorta and compared between in each phase. Correlations between ECV values in each phase with the albumin-bilirubin (ALBI) score and grade, fibrosis-4 index (Fib-4), and clinical fibrosis stage were statistically analysed.
RESULTS: No significant difference was found in ECV values between the 3- and 5-min delayed phase images (P = 0.056). The ratio of ECV values for 3- to 5-min delayed phase images was 0.984 ± 0.078, ranging from 0.85 to 1.16. The ECV calculated on 3- and 5-min delayed phase images showed strong and moderate correlations with ALBI grade (Spearman's ρ; 0.763 and 0.724, respectively) and ALBI score (Spearman's ρ; 0.707 and 0.668, respectively) and also showed moderate correlations with Fib-4 (Spearman's ρ; 0.548 and 0.543, respectively) and clinical fibrosis stage (Spearman's ρ; 0.468 and 0.435, respectively).
CONCLUSION: Three-minute delayed phase images were found to be equivalent to 5-min delayed phase images for the calculation of ECV.
ADVANCES IN KNOWLEDGE: Three-minute delayed phase images were found to be equivalent to 5-min delayed phase images for calculating ECV in the same patients, and both 3- and 5-min delayed phase CT scans showed strong and moderate correlation with serum fibrous makers, including ALBI score and grade and fibrosis-4 index. This could facilitate the clinical use of hepatic ECV in daily practice.