该双中心回顾性研究纳入111例经组织学确诊的胰腺导管腺癌患者,利用18F-FDG PET/CT影像组学特征构建SVM、LR和RF模型预测组织学分级。测试集中PET/CT联合模型的平均AUC最高达0.844,PET和CT单独模型的AUC分别为0.773和0.770。作者认为该模型可实现术前组织学分级,但缺乏外部验证。

要点

  • PET/CT联合影像组学模型对PDAC组织学分级预测性能最佳,测试集平均AUC达0.844。
  • PET单独模型平均AUC为0.773,CT单独模型为0.770,均低于PET/CT联合模型。
  • 该研究为双中心回顾性研究,纳入111例PDAC患者,缺乏外部验证。

核心结论

  • PET/CT影像组学模型可实现PDAC术前组织学分级,但缺乏外部验证。

研究设计与样本

  • 双中心回顾性研究,纳入111例经组织学确诊的PDAC患者,采用uRP进行PET和CT图像逐层肿瘤分割并提取特征,使用LASSO进行特征选择,采用SVM、RF和LR算法建模,通过5折交叉验证评估模型性能。

诊断标准与关键数值

  • 肿瘤分为高级别(未分化或低分化)和低级别(中分化或高分化);测试集中PET模型SVM、LR、RF的平均AUC分别为0.773、0.772、0.760;CT模型分别为0.764、0.770、0.576;PET/CT模型分别为0.840、0.844、0.773。

临床应用与阅片要点

  • 作者认为该模型可作为新辅助治疗分层和个性化医疗决策的临床工具。

局限性

  • 缺乏外部验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To explore the value of radiomics features derived from 18F-FDG PET/CT images in predicting the histological grade of pancreatic ductal adenocarcinoma (PDAC).

MATERIALS AND METHODS: A retrospective analysis was conducted using data from patients with suspected pancreatic cancer, who histologically confirmed as PDAC within 14 days after 18F-FDG PET/CT scan in one of two hospitals. Tumors were divided into high-grade (undifferentiated or poorly differentiated), and low-grade (moderately or well differentiated). Two researchers independently used uRP to perform layer-by-layer tumor segmentation in both PET and CT images of each patient, and extract features. Model performance was evaluated using 5-fold cross-validation on the entire multi-center cohort, with results averaged across all folds. The least absolute shrinkage and selection was used for feature selection, and support vector machine (SVM), random forest (RF), and logistic regression (LR) were employed to distinguish the grade of PDAC. The performance of the model was evaluated using the receiver operating characteristic curve.

RESULTS: This study comprised 111 patients (72 males and 39 females), comprising 52 patients with high-grade PDAC tumors and 59 patients with low-grade. A series of models were established by SVM, LR, and RF algorithms based on selected features. In the test set, the mean areas under the curve (AUCs) for PET image-based models using SVM, LR, and RF algorithms were 0.773, 0.772, and 0.760. For CT-based models, the mean AUCs were 0.764, 0.770, and 0.576. For PET/CT-based models, the mean AUCs were 0.840, 0.844, and 0.773.

CONCLUSION: Despite the lack of external validation, the PET/CT-derived radiomics model enables accurate preoperative histological grading of PDAC, offering a clinically actionable tool to neoadjuvant therapy stratification and further guide personalized medical decision-making.

来源:Eur J Radiol,查看原文。版权归原作者所有。