MRISegmenter:一种用于T1加权腹部MRI的完全准确且稳健的自动化多器官与结构分割工具
本研究在美国国立卫生研究院临床中心回顾性纳入195例患者共780次T1加权腹部MRI扫描,每个序列含62个腹部器官与结构的体素级标注,训练并评估三维分割模型MRISegmenter。内部测试集平均Dice评分0.861±0.118、NSD 0.924±0.073;外部测试集AMOS22平均Dice评分0.829±0.133、NSD 0.908±0.067,Duke Liver平均Dice评分0.933±0.015、NSD 0.929±0.021。结论认为MRISegmenter能在T1加权腹部MRI上对62个器官与结构提供准确且稳健的分割。
要点
- MRISegmenter可在T1加权腹部MRI上自动分割62个腹部器官与结构。
- 内部测试集平均Dice评分0.861±0.118,平均NSD 0.924±0.073。
- 外部测试集AMOS22平均Dice评分0.829±0.133,Duke Liver平均Dice评分0.933±0.015。
核心结论
- MRISegmenter在T1加权腹部MRI上对62个器官与结构提供了准确且稳健的分割。
研究设计与样本
- 回顾性研究,在美国国立卫生研究院临床中心纳入195例患者共780次MRI扫描,每个序列含62个腹部器官与结构的体素级标注。
关键影像表现/征象
- 数据集包含轴位平扫T1加权及增强后动脉期、门静脉期和延迟期T1加权序列,每个序列均含62个腹部器官与结构的体素级标注。
诊断标准与关键数值
- 以放射科医师核实的参考标准标注为对照,采用Dice相似系数与归一化表面距离(NSD)评估分割准确性。
临床应用与阅片要点
- MRISegmenter工具与数据集已在https://github.com/rsummers11/MRISegmenter公开。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background There is a pressing demand to develop an automated segmentation tool for abdominal MRI that can provide accurate and robust segmentation in more than 60 abdominal organs and structures. Purpose To develop and evaluate the accuracy and robustness of an automated multiorgan and structure segmentation tool for T1-weighted abdominal MRI. Materials and Methods In this retrospective study, a T1-weighted abdominal MRI dataset composed of axial precontrast T1-weighted and contrast-enhanced T1-weighted arterial, portal venous, and delayed phases for each patient in a randomly selected sample was included at the National Institutes of Health Clinical Center. Each MRI series contained voxel-level annotations of 62 abdominal organs and structures. A three-dimensional segmentation (nnU-Net) model, called MRISegmenter, was trained on this dataset. This internal dataset was then randomly split into training and internal test sets. Evaluation was conducted on the internal test set and two external test sets (Abdominal Multi-Organ Segmentation Challenge 2022 [AMOS22] and Duke Liver). The predicted segmentations were compared against the radiologist-verified reference standard annotations using means ± SDs for the Dice similarity coefficient (Dice score) and normalized surface distance (NSD). The segmentation tool and dataset are publicly available at https://github.com/rsummers11/MRISegmenter. Results A total of 195 patients (training set, 135 patients [mean age, 54.7 years ± 16.3 {SD}; 72 male patients, 63 female patients]; internal test set, 60 patients [mean age, 51.1 years ± 14.4; 26 male patients, 34 female patients]) with 780 MRI scans containing 62 annotations each were included. On the internal test set, MRISegmenter achieved a mean Dice score of 0.861 ± 0.118 and a mean NSD of 0.924 ± 0.073. On external test sets AMOS22 (60 MRI scans) and Duke Liver (95 patients; 172 MRI scans), MRISegmenter attained a mean Dice score of 0.829 ± 0.133 and a mean NSD of 0.908 ± 0.067 and a mean Dice score of 0.933 ± 0.015 and a mean NSD of 0.929 ± 0.021, respectively. Conclusion MRISegmenter provided accurate and robust segmentation of 62 organs and structures at T1-weighted abdominal MRI. © RSNA, 2025 Supplemental material is available for this article. See also the editorial by Murphy in this issue.
引用
- Zhuang Y, Mathai TS, Mukherjee P, et al. MRISegmenter: A Fully Accurate and Robust Automated Multiorgan and Structure Segmentation Tool for T1-weighted Abdominal MRI. Radiology. 2025. PMID: 40261178. doi:10.1148/radiol.241979
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。