文献速递心血管CT

人工智能在CT血管造影中检测冠状动脉狭窄与钙化斑块:系统综述与Meta分析

Artificial Intelligence in CT Angiography for the Detection of Coronary Artery Stenosis and Calcified Plaque: A Systematic Review and Meta-analysis.
PubMed 文献 · Acad Radiol · 2025-04-14

该系统综述与Meta分析纳入17项研究共5560例患者,评估AI在CTA上检测冠状动脉狭窄与钙化斑块的诊断效能。对于狭窄≥50%,AI敏感度0.92、特异度0.87、AUC 0.96,优于放射科医师的敏感度0.85、特异度0.84、AUC 0.91;对于狭窄≥70%,AI敏感度0.88、特异度0.96、AUC 0.98;钙化斑块检测AI敏感度0.93、特异度0.94、AUC 0.98。

要点

  • AI检测冠状动脉狭窄≥50%的AUC为0.96,高于放射科医师的0.91。
  • AI检测狭窄≥70%的敏感度0.88、特异度0.96、AUC 0.98。
  • AI检测钙化斑块的敏感度0.93、特异度0.94、AUC 0.98。

核心结论

  • 基于AI的CT在识别冠状动脉≥50%狭窄方面诊断效能优于临床医师,在识别≥70%狭窄和钙化斑块方面表现出色;但存在回顾性研究设计和CTA技术异质性等局限,需通过前瞻性多中心试验进一步外部验证。

研究设计与样本

  • 系统综述与Meta分析,检索PubMed、Web of Science和Embase至2024年10月,最终纳入17项研究共5560例患者及图像;采用双变量随机效应模型合并敏感度与特异度,用I2统计量评估异质性,用QUADAS-2工具评估偏倚风险,用GRADE系统分级证据。

诊断标准与关键数值

  • 冠状动脉狭窄≥50%:AI敏感度0.92(95%CI 0.88-0.95)、特异度0.87(95%CI 0.80-0.92)、AUC 0.96(95%CI 0.94-0.97);放射科医师敏感度0.85(95%CI 0.67-0.94)、特异度0.84(95%CI 0.62-0.94)、AUC 0.91(95%CI 0.89-0.93)。
  • 冠状动脉狭窄≥70%:AI敏感度0.88(95%CI 0.70-0.96)、特异度0.96(95%CI 0.90-0.99)、AUC 0.98(95%CI 0.96-0.99)。
  • 钙化斑块检测:AI敏感度0.93(95%CI 0.84-0.97)、特异度0.94(95%CI 0.88-0.96)、AUC 0.98(95%CI 0.96-0.99)。

临床应用与阅片要点

  • 原文结论指出AI在识别冠状动脉≥50%狭窄方面诊断效能优于临床医师,在识别≥70%狭窄和钙化斑块方面表现出色。
  • 原文未据此给出推荐。

局限性

  • 局限性包括回顾性研究设计。
  • 局限性包括CTA技术的异质性。
  • 需要通过前瞻性、多中心试验进行进一步外部验证以确认这些发现。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: We aimed to evaluate the diagnostic performance of artificial intelligence (AI) in detecting coronary artery stenosis and calcified plaque on CT angiography (CTA), comparing its diagnostic performance with that of radiologists.

METHODS: A thorough search of the literature was performed using PubMed, Web of Science, and Embase, focusing on studies published until October 2024. Studies were included if they evaluated AI models in detecting coronary artery stenosis and calcified plaque on CTA. A bivariate random-effects model was employed to determine combined sensitivity and specificity. Study heterogeneity was assessed using I2 statistics. The risk of bias was assessed using the revised quality assessment of diagnostic accuracy studies-2 tool, and the evidence level was graded using the Grading of Recommendations Assessment, Development and Evalutiuon (GRADE) system.

RESULTS: Out of 1071 initially identified studies, 17 studies with 5560 patients and images were ultimately included for the final analysis. For coronary artery stenosis ≥50%, AI showed a sensitivity of 0.92 (95% CI: 0.88-0.95), specificity of 0.87 (95% CI: 0.80-0.92), and AUC of 0.96 (95% CI: 0.94-0.97), outperforming radiologists with sensitivity of 0.85 (95% CI: 0.67-0.94), specificity of 0.84 (95% CI: 0.62-0.94), and AUC of 0.91 (95% CI: 0.89-0.93). For stenosis ≥70%, AI achieved a sensitivity of 0.88 (95% CI: 0.70-0.96), specificity of 0.96 (95% CI: 0.90-0.99), and AUC of 0.98 (95% CI: 0.96-0.99). In calcified plaque detection, AI demonstrated a sensitivity of 0.93 (95% CI: 0.84-0.97), specificity of 0.94 (95% CI: 0.88-0.96), and AUC of 0.98 (95% CI: 0.96-0.99)."

CONCLUSION: AI-based CT demonstrated superior diagnostic performance compared to clinicians in identifying ≥50% stenosis in coronary arteries and showed excellent diagnostic performance in recognizing ≥70% coronary artery stenosis and calcified plaque. However, limitations include retrospective study designs and heterogeneity in CTA technologies. Further external validation through prospective, multicenter trials is required to confirm these findings.

DATA AVAILABILITY STATEMENT: The original findings of this research are included in the article. For additional inquiries, please contact the corresponding authors.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Du M, He S, Liu J, et al. Artificial Intelligence in CT Angiography for the Detection of Coronary Artery Stenosis and Calcified Plaque: A Systematic Review and Meta-analysis. Acad Radiol. 2025. PMID: 40234162. doi:10.1016/j.acra.2025.03.054

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。