70 kV管电压联合深度学习图像重建对瘦小患者冠状动脉CT血管成像的辐射与对比剂剂量降低研究
研究将60例行冠状动脉CT血管成像的BMI≤25 kg/m2患者随机分为两组:A组采用120 kV、对比剂0.8 mL/kg及50%ASIR-V重建,B组采用70 kV、对比剂0.5 mL/kg及50%ASIR-V、DLIR-L、DLIR-M、DLIR-H重建。B组较A组辐射剂量降低75.6%、对比剂剂量降低32.9%,且B组DLIR各水平提供更高SNR、CNR和主观评分,DLIR-H噪声最低、主观评分最高。
要点
- BMI≤25 kg/m2患者行CCTA时,70 kV联合DLIR较120 kV联合ASIR-V降低辐射剂量75.6%、对比剂剂量32.9%。
- B组冠状动脉CT值高于A组,DLIR-L、DLIR-M、DLIR-H的SNR、CNR及主观评分均较高。
- DLIR-H在B组中噪声最低、主观评分最高。
核心结论
- 对于BMI≤25 kg/m2的瘦小患者,CCTA采用70 kV联合DLIR可显著降低辐射剂量和对比剂剂量,同时提高图像质量,其中DLIR-H对图像质量改善效果最佳。
研究设计与样本
- 随机对照研究,纳入60例行CCTA的BMI≤25 kg/m2患者,随机分为A组(120 kV、对比剂0.8 mL/kg、50%ASIR-V重建)和B组(70 kV、对比剂0.5 mL/kg、50%ASIR-V及DLIR-L、DLIR-M、DLIR-H重建)。
关键影像表现/征象
- B组冠状动脉CT值高于A组。
- B组DLIR-L、DLIR-M、DLIR-H的SNR值和CNR值均高于A组。
- B组DLIR-L、DLIR-M、DLIR-H的主观评分均高于A组。
- B组中DLIR-H噪声最低、主观评分最高。
诊断标准与关键数值
- 图像质量由2名放射科医师采用五分法主观评分。
- B组较A组辐射剂量降低75.6%,对比剂剂量降低32.9%。
临床应用与阅片要点
- 作者指出,70 kV联合DLIR-H可用于瘦小患者的CCTA,在显著降低辐射剂量和对比剂剂量的同时提高图像质量。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the radiation and contrast dose reduction potential of combining 70 kV with deep learning image reconstruction (DLIR) in coronary computed tomography angiography (CCTA) for slender patients with body-mass-index (BMI) ≤25 kg/m2.
METHODS: Sixty patients for CCTA were randomly divided into 2 groups: group A with 120 kV and contrast agent dose of 0.8 mL/kg, and group B with 70 kV and contrast agent dose of 0.5 mL/kg. Group A used adaptive statistical iterative reconstruction-V (ASIR-V) with 50% strength level (50%ASIR-V) while group B used 50% ASIR-V, DLIR of low level (DLIR-L), DLIR of medium level (DLIR-M), and DLIR of high level (DLIR-H) for image reconstruction. The CT values and SD values of coronary arteries and pericardial fat were measured, and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The image quality was subjectively evaluated by 2 radiologists using a five-point scoring system. The effective radiation dose (ED) and contrast dose were calculated and compared.
RESULTS: Group B significantly reduced radiation dose by 75.6% and contrast dose by 32.9% compared to group A. Group B exhibited higher CT values of coronary arteries than group A, and DLIR-L, DLIR-M, and DLIR-H in group B provided higher SNR values and CNR values and subjective scores, among which DLIR-H had the lowest noise and highest subjective scores.
CONCLUSION: Using 70 kV combined with DLIR significantly reduces radiation and contrast dose while improving image quality in CCTA for slender patients with DLIR-H having the best effect on improving image quality.
ADVANCES IN KNOWLEDGE: The 70 kV and DLIR-H may be used in CCTA for slender patients to significantly reduce radiation dose and contrast dose while improving image quality.
引用
- Ren Z, Shen L, Zhang X, et al. Radiation and contrast dose reduction in coronary CT angiography for slender patients with 70 kV tube voltage and deep learning image reconstruction. Br J Radiol. 2025. PMID: 40205479. doi:10.1093/bjr/tqaf077
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。