文献速递心血管MRCT

3-T非增强全心bSSFP冠状动脉MR血管成像与改良Dixon水脂分离序列的性能比较

Performance of 3-T Nonenhanced Whole-Heart bSSFP Coronary MR Angiography: A Comparison with 3-T Modified Dixon Water-Fat Separation Sequence.
PubMed 文献 · Radiol Cardiothorac Imaging · 2025-01-01

研究连续纳入疑似冠心病患者,在冠状动脉CT血管成像后行3-T非增强全心bSSFP与改良Dixon水脂分离冠状动脉MR血管成像,比较采集成功率、图像质量及以CCTA为参考的狭窄诊断效能。bSSFP在采集成功率、主观评分、信噪比、对比噪声比及诊断敏感度和特异度方面均显示更优,作者认为3-T非增强bSSFP序列可能推荐用于更广泛的临床应用。

要点

  • 3-T非增强全心bSSFP冠状动脉MR血管成像采集成功率为93.5%,高于改良Dixon水脂分离序列的80.6%。
  • bSSFP整体主观图像质量评分为5分,改良Dixon序列为4分,两者差异有统计学意义。
  • 以CCTA为参考,bSSFP预测狭窄≥50%的敏感度和特异度在患者、血管、节段水平均较高。

核心结论

  • 与改良Dixon水脂分离方法相比,改进的非增强全心bSSFP序列在3-T成像中表现优异,非增强bSSFP冠状动脉MR血管成像序列可能推荐用于更广泛的临床应用。

研究设计与样本

  • 2023年9月至2023年12月连续纳入疑似冠心病患者,在冠状动脉CT血管成像后行bSSFP与mDixon冠状动脉MR血管成像,比较两种序列的采集成功率、主观图像质量评分、客观图像质量测量及以CCTA为参考标准的冠状动脉狭窄诊断效能;62例完成两种序列,最终分析49例(男30例、女19例;平均年龄62岁±10[SD])。

诊断标准与关键数值

  • bSSFP预测狭窄≥50%的敏感度和特异度:按患者分别为94.7%(95%CI:71.9,99.7)和96.7%(95%CI:80.9,99.8)。
  • bSSFP预测狭窄≥50%的敏感度和特异度:按血管分别为95.8%(95%CI:76.9,99.8)和96.7%(95%CI:91.3,98.9)。
  • bSSFP预测狭窄≥50%的敏感度和特异度:按节段分别为96.6%(95%CI:80.4,99.8)和99.0%(95%CI:97.3,99.7)。
  • bSSFP与mDixon的采集成功率分别为93.5%与80.6%(P = .021)。
  • bSSFP与mDixon的整体主观图像质量评分分别为5分与4分(P < .001),表观信噪比分别为33.4±10.6与20.7±7.5(P < .001),对比噪声比分别为14.9±6.2与7.0±3.1(P < .001)。

临床应用与阅片要点

  • 作者认为,3-T非增强bSSFP冠状动脉MR血管成像序列可能推荐用于更广泛的临床应用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To compare the performance of improved nonenhanced whole-heart balanced steady-state free precession (bSSFP) coronary MR angiography (CMRA) with that of the modified Dixon (mDixon) water-fat separation method at 3-T imaging. Materials and Methods From September 2023 to December 2023, patients with suspected coronary artery disease who underwent bSSFP and mDixon CMRA after coronary CT angiography (CCTA) were consecutively recruited. The two sequences' acquisition success rates, subjective image quality scores, objective image quality measurements, and diagnostic performance for coronary stenosis with CCTA as the reference standard were analyzed. Results Sixty-two participants completed two CMRA sequences. Data from 49 participants (30 male and 19 female participants; mean age, 62 years ± 10 [SD]) were ultimately analyzed. The acquisition success rates, overall subjective image quality scores, apparent signal-to-noise ratios, and contrast-to-noise ratios of bSSFP and mDixon were significantly different: 93.5% versus 80.6% (P = .021), 5 versus 4 (P < .001), 33.4 ± 10.6 versus 20.7 ± 7.5 (P < .001), and 14.9 ± 6.2 versus 7.0 ± 3.1 (P < .001), respectively. The sensitivity and specificity of bSSFP in predicting stenosis greater than or equal to 50% were 94.7% (95% CI: 71.9, 99.7) and 96.7% (95% CI: 80.9, 99.8) per participant, 95.8% (95% CI: 76.9, 99.8) and 96.7% (95% CI: 91.3, 98.9) per vessel, and 96.6% (95% CI: 80.4, 99.8) and 99.0% (95% CI: 97.3, 99.7) per segment, respectively. Conclusion Compared with the mDixon water-fat separation method, the improved nonenhanced whole-heart bSSFP sequence performed excellently at 3-T imaging. Nonenhanced bSSFP CMRA sequences at 3-T imaging may be recommended for broader clinical applications. Keywords: Coronary Arteries, Imaging Sequences, Comparative Studies, Technology Assessment, Cardiac, MR Angiography, Coronary Angiography, MRI, Image Quality Enhancement Supplemental material is available for this article. © RSNA, 2025.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Yuan Y, Jiang Y, Lu GM, et al. Performance of 3-T Nonenhanced Whole-Heart bSSFP Coronary MR Angiography: A Comparison with 3-T Modified Dixon Water-Fat Separation Sequence. Radiol Cardiothorac Imaging. 2025. PMID: 40243554. doi:10.1148/ryct.240162

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。