文献速递外周血管介入CT

主髂动脉血流动力学与几何形态对腹主动脉腔内修复术后血栓并发症的影响

Impact of aorto-iliac hemodynamics and geometry on thrombotic complications following abdominal aortic endovascular aneurysm repair.
PubMed 文献 · Eur J Radiol · 2025-04-15

回顾性分析47例腹主动脉EVAR患者,比较29条血栓性髂支与65条正常髂支及36段正常与11段血栓性主动脉段;基于CTA重建3D模型行CFD模拟。血栓性髂支表现为更低TAWSS、更高OSI、更大髂动脉最大周长与截面积及更高迂曲指数;主动脉段血栓仅与更大血管尺寸相关。

要点

  • 血栓性髂支TAWSS更低(0.14 Pa vs 0.78 Pa),OSI更高(0.049 vs 0.0001)。
  • 血栓性髂支最大周长、截面积及迂曲指数均高于非血栓段。
  • 主动脉段血栓仅与更大最大周长和截面积相关,TAWSS差异无统计学意义。

核心结论

  • EVAR术后髂支血栓事件与更低TAWSS、更高OSI、更大血管尺寸及更高迂曲指数相关;主动脉段血栓并发症仅与更大血管尺寸相关。

研究设计与样本

  • 回顾性分析47例腹主动脉EVAR患者,比较29条血栓性髂支与65条正常髂支,并评估36段正常与11段血栓性主动脉段;基于CTA重建患者个体化3D主髂动脉管腔模型,提取几何参数并行CFD模拟评估TAWSS与OSI。

诊断标准与关键数值

  • 血栓性髂支TAWSS 0.14 Pa vs 正常髂支0.78 Pa(p<0.001)。
  • 血栓性髂支OSI 0.049 vs 正常髂支0.0001(p<0.001)。
  • 血栓性髂支最大髂动脉周长43.69 mm vs 正常40.47 mm(p=0.007),最大截面积150.66 mm2 vs 126.65 mm2(p=0.006),迂曲指数平均差0.026(p=0.002)。
  • 血栓性主动脉段TAWSS 0.08 Pa vs 正常0.103 Pa(p=0.498),最大周长79.98±6.78 mm vs 70.94±10.57 mm(p=0.011),截面积495.69±87.2 mm2 vs 398.89±123.34 mm2(p=0.021)。

临床应用与阅片要点

  • 作者认为几何与血流动力学因素在EVAR术后血栓形成中具有重要意义。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study investigated the relationship between hemodynamic and geometry factors and the risk of thrombosis following aortic endovascular aneurysm repair (EVAR).

MATERIALS AND METHODS: A retrospective analysis was conducted on data from 47 patients underwent abdominal EVAR. 29 thrombotic iliac limbs were compared with 65 normal iliac limbs. Additionally, 36 normal and 11 thrombotic aortic segments were also evaluated. Patient-specific 3D models of aorto-iliac lumen were reconstructed from computed tomography angiography (CTA). These models were used to extract geometric parameters and to perform computational fluid dynamics (CFD) simulations to assess Time-average wall shear stress (TAWSS) and oscillatory shear index (OSI).

RESULTS: Thrombotic iliac segments showed lower TAWSS (0.14 Pa vs. 0.78 Pa, p < 0.001), higher OSI (0.049 vs. 0.0001, p < 0.001), higher maximum iliac circumference (43.69 mm vs. 40.47 mm, p = 0.007), higher maximum iliac sectional area (150.66 mm2 vs. 126.65 mm2, p = 0.006) and an elevated iliac tortuosity index (mean difference: 0.026, p = 0.002) comparing to non-thrombotic segments. Thrombotic aortic segments exhibited lower TAWSS (0.08 Pa vs. 0.103 Pa, p = 0.498), higher maximum aortic circumference (79.98 ± 6.78 mm vs. 70.94 ± 10.57 mm, p = 0.011) and sectional area (495.69 ± 87.2 mm2 vs. 398.89 ± 123.34 mm2, p = 0.021).

CONCLUSION: Post-EVAR thrombotic events in iliac limbs were associated with lower TAWSS, higher OSI, larger vessel dimensions and elevated tortuosity index. In aortic segments, thrombosis complications were associated with only larger vessel dimensions. These findings emphasize the importance of geometric and hemodynamic factors in developing thrombosis following EVAR.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Ngo DHA, Lee KH, Lee JI, et al. Impact of aorto-iliac hemodynamics and geometry on thrombotic complications following abdominal aortic endovascular aneurysm repair. Eur J Radiol. 2025. PMID: 40250006. doi:10.1016/j.ejrad.2025.112116

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。