心脏肿物高分辨率动态表征:射频毁损三维梯度回波序列
本研究评估VIBE序列对心脏肿物和血栓的检出及其与血池的鉴别能力,比较平扫、动脉期和静脉期图像上病变的信噪比和对比噪声比。结果显示VIBE图像的信噪比和对比噪声比低于常规增强图像,但可在30秒屏气内快速获得平扫、动脉期和静脉期图像,作者认为可作为未来动态成像研究的初步研究。
要点
- VIBE序列可在30秒屏气时间内获得心脏肿物和血栓的平扫、动脉期和静脉期高分辨率三维图像。
- VIBE图像上血栓、血池和心肌的信噪比和对比噪声比低于常规增强图像。
- 作者认为本研究可作为未来评估动态图像的初步研究。
核心结论
- VIBE序列可快速获得心脏肿物和血栓的平扫、动脉期和静脉期图像,但其信噪比和对比噪声比低于常规增强图像,作者认为本研究可作为未来动态成像研究的初步研究。
研究设计与样本
- 本研究评估心脏肿物和血栓在VIBE序列平扫、早期增强和晚期增强图像上的表现,在病变显示最佳的期相手动勾画感兴趣区并复制到其他期相。
诊断标准与关键数值
- 信噪比(SNR)按信号强度除以背景强度标准差计算。
- 对比噪声比(CNR)按血栓信噪比减心肌信噪比、血栓信噪比减血池信噪比计算。
- VIBE图像上血栓、血池和心肌的信噪比和对比噪声比低于常规增强图像。
临床应用与阅片要点
- 作者认为VIBE序列可在30秒屏气内快速获得心脏肿物和血栓的平扫、动脉期和静脉期图像。
- 作者认为本研究可作为未来评估动态图像的初步研究。
局限性
- 作者指出VIBE图像获得的信噪比和对比噪声比低于常规增强图像。
- 作者指出本研究可作为未来研究的初步研究。
- 作者指出据其所知,这是首篇关于VIBE图像上心脏肿物视觉评估的论文。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Volumetric interpolated breath-hold examination (VIBE) sequence is a radio-frequency-spoiled gradient echo sequence that is mostly used in the evaluation of soft tissues, allows dynamic high-resolution images to be taken in 30 seconds of breath-holding time in MRI, and is used to create 3D images. In this study, we aimed to determine the detectability of cardiac masses and thrombi and their differentiation from the blood pool with the T1 VIBE imaging method.
METHODS: Precontrast, early and late postcontrast VIBE images were evaluated. Lesion contours were drawn with a free-hand regìon of ìnterest (ROI) in the phase in which the lesion was better depicted. All ROIs were placed in the phase where the lesion appeared best and then copied to other phases.
RESULTS: Sìgnal to noìse ratìo (SNR) was calculated as SI/SD of background intensity, CNR was calculated as SNR thrombus-SNR myocardium and SNR thrombus-SNR blood pool. SNR and CNR values of thrombus, blood pool, and myocardium measured at maps and contrast-enhanced images were compared with each other.
CONCLUSIONS: There are many sequences used routinely to detect cardiac masses and thrombi. Many of these techniques require long acquisition time. With the VIBE sequence, precontrast, arterial, and venous images of the lesion can be obtained quickly. Although the SNR and CNR values obtained with VIBE images are lower than those with routine post-contrast images, our study can be considered a preliminary study for future studies to evaluate dynamic images.
ADVANCES IN KNOWLEDGE: For our knowledge, this is the first paper written on the visual assessment of cardiac masses on VIBE images.
引用
- Peker E, Ünal S, Ergüden RE, et al. High resolution-dynamic characterization of cardiac masses: radio-frequency spoiled 3D gradient echo sequence. Br J Radiol. 2025. PMID: 40293821. doi:10.1093/bjr/tqaf093
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。