回顾性分析单中心2019年3月至2021年12月566例毗邻脏层胸膜(距离小于1 cm)的外周肺病变经皮经胸空心针活检,技术成功率100%、诊断成功率90.1%(510/566),术后气胸发生率19.4%(110/566),需延长住院的严重不良事件发生率3.4%(19/566)。病变直径小于10 mm(p<0.001)与诊断失败相关,经叶间裂路径(p=0.042)和较长穿刺道长度(p=0.018)与术后气胸发生相关。

要点

  • 外周肺病变经皮空心针活检诊断成功率90.1%(510/566),术后气胸发生率19.4%(110/566)。
  • 病变直径小于10 mm(p<0.001)与诊断失败相关。
  • 经叶间裂路径(p=0.042)和较长穿刺道长度(p=0.018)与术后气胸发生相关。

核心结论

  • 经皮经胸空心针活检是外周肺病变有效且安全的诊断方法,诊断成功率高、术后气胸发生率低。

研究设计与样本

  • 单中心回顾性研究,纳入2019年3月至2021年12月566例毗邻脏层胸膜(距离小于1 cm)的外周肺病变经皮经胸空心针活检操作,复习电子病历包括住院记录、影像报告和操作报告,采用单因素和多因素logistic回归分析操作细节和病变特征与诊断失败及术后气胸的相关因素。

诊断标准与关键数值

  • 技术成功率100%,诊断成功率90.1%(510/566)。
  • 术后气胸发生率19.4%(110/566)。
  • 需延长住院的严重不良事件发生率3.4%(19/566)。
  • 病变直径小于10 mm与诊断失败相关(p<0.001)。
  • 经叶间裂路径(p=0.042)和较长穿刺道长度(p=0.018)与术后气胸发生相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the safety and efficacy of percutaneous transthoracic core needle biopsy (PCNB) for peripheral lung lesions and to identify factors associated with diagnostic failure and occurrence of significant pneumothorax.

MATERIAL AND METHODS: Data from 566 PCNB procedures on lung lesions in contact with or adjacent to the visceral pleura at a distance less than 1 cm, performed at a single center between March 2019 and December 2021, were retrospectively reviewed. The electric medical records, including inpatient notes, radiology reports, and procedure reports were reviewed. Procedure details and lesion(s) characteristics were analyzed using univariate and multivariate logistic regression analyses to identify factors associated with diagnostic failure and postprocedural pneumothorax.

RESULTS: The technical and diagnostic success rates were 100% and 90.1% (510/566), respectively. Postprocedural pneumothorax occurred in 19.4% (110/566) of patients. The severe adverse events that required prolongation of the hospital admission occurred in 3.4% (19/566). Univariate and multivariate analyses revealed that lesion diameter less than 10 mm (p<0.001) was associated with diagnostic failure, and the transfissural route (p = 0.042) and longer tract length (p = 0.018) were associated with the occurrence of postprocedural pneumothorax.

CONCLUSION: PCNB was an effective and safe diagnostic method for peripheral lung lesions, with a high diagnostic success rate and low incidence of postprocedural pneumothorax.