18F-FDG PET/CT影像组学分析预测胸膜附着非小细胞肺癌脏层胸膜侵犯
回顾性纳入两个医疗中心974例伴胸膜附着的非小细胞肺癌患者,构建整合临床因素与18F-FDG PET/CT影像组学特征的联合模型预测脏层胸膜侵犯。联合模型在训练集、内部验证集和外部验证集的AUC分别为0.869、0.858和0.863,均显著高于PET/CT影像组学模型(AUC分别为0.828、0.782和0.704,均P<0.001)。联合模型在最大肿瘤直径≤3 cm患者和腺癌患者中AUC分别为0.876和0.877,并据此开发了校准曲线拟合良好的列线图。
要点
- 联合PET/CT影像组学-临床模型预测胸膜附着NSCLC的脏层胸膜侵犯,外部验证AUC为0.863。
- 联合模型AUC在训练集、内部验证集和外部验证集均显著高于单纯影像组学模型(均P<0.001)。
- 最大肿瘤直径≤3 cm患者中联合模型AUC为0.876,腺癌患者中为0.877。
核心结论
- 联合PET/CT影像组学-临床模型在预测伴胸膜附着的NSCLC脏层胸膜侵犯状态方面具有优势。
研究设计与样本
- 回顾性纳入两个医疗中心974例NSCLC患者(VPI存在408例,VPI不存在566例),收集临床数据和PET/CT影像组学特征,构建影像组学评分及联合PET/CT影像组学-临床模型,采用ROC分析评估预测性能。
诊断标准与关键数值
- 联合PET/CT影像组学-临床模型预测VPI的AUC在训练集(n=569)为0.869,内部验证集(n=245)为0.858,外部验证集(n=160)为0.863。
- PET/CT影像组学模型预测VPI的AUC在训练集为0.828,内部验证集为0.782,外部验证集为0.704,联合模型均显著高于影像组学模型(均P<0.001)。
- 最大肿瘤直径≤3 cm患者(n=537)中联合模型AUC为0.876,腺癌患者(n=659)中联合模型AUC为0.877。
临床应用与阅片要点
- 基于联合模型开发的列线图校准曲线拟合良好,可用于预测伴胸膜附着NSCLC患者的VPI状态。
- 联合模型在最大肿瘤直径≤3 cm和腺癌患者中同样表现出较高的预测效能(AUC分别为0.876和0.877)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: This study aimed to establish and validate a preoperative model that integrates clinical factors and radiomic features from 2-[18F]-fluoro-2-deoxy-D-glucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) for predicting visceral pleural invasion (VPI) in non-small cell lung cancer (NSCLC) with radiological pleural attachment.
MATERIALS AND METHODS: A total of 974 NSCLC patients (408 with VPI-present and 566 with VPI-absent) were retrospectively included from two medical centres. Clinical data and PET/CT radiomic features were collected. The optimal predictors from these radiomic features were selected to create the radiomics score (Rad-score) for the PET/CT radiomics model. Significant clinical factors and Rad-scores were incorporated into a combined PET/CT radiomics-clinical model. The predictive performance of the models was assessed using receiver operating characteristic (ROC) analysis.
RESULTS: The combined PET/CT radiomics-clinical model predicted VPI status with areas under the ROC curve (AUCs) of 0.869, 0.858, and 0.863 in the training set (n=569), internal validation set (n=245), and external validation set (n=160), respectively. These were significantly higher than the AUCs of the PET/CT radiomics model, which were 0.828, 0.782, and 0.704 (all P<0.001). In patients with a maximum tumour diameter (Dmax) ≤ 3 cm (n=537) and in patients with adenocarcinoma (n=659), the AUCs of the combined model were 0.876 and 0.877, respectively. A nomogram based on the combined model was developed, with well-fitted calibration curves.
CONCLUSION: The combined PET/CT radiomics-clinical model provides an advantage in predicting VPI status in NSCLC with pleural attachment.
引用
- Li Y, Qi JJ, Shen MJ, et al. Radiomics analysis of 18F-FDG PET/CT for visceral pleural invasion in non-small cell lung cancer with pleural attachment. Clin Radiol. 2025. PMID: 40203606. doi:10.1016/j.crad.2025.106867
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。